Get complete information related to latest Sausage Filler Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Sausage Filler Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Sausage Filler Tenders.
Tender For purchase of lab equipments for gptc tvt chemistry department - purchase, digital electronic balance /analytical balance load capacity: minimum 500 g readability: 0.01 g linearity: 0.02g display: lcd/led tare function: required top pan type power supply: 220 240 v ac, 50 hz, digital tds meter measuring range: 0 9990 ppm resolution: 1 ppm display: lcd automatic temperature compensation (atc): required waterproof: minimum ip67 protectionpower source: battery operated (button cell/aaa battery), digital ph meter benchtop model ph type microprocessor/microcontrolle r ph range: 0 14 resolution: 0.01 ph accuracy: 0.05 ph or better combined ph electrode with temperature sensor two or three-point calibration facility temperature compensation type automatic display: lcd power supply: 220 240 v ac, 50 hz warranty minimum 1 year , laboratory heating mantle (knitted glass yarn) capacity: 500ml temperature range: ambient to 350 c energy regulator/control knob: required * power supply: 220-240 v ac, 50 hz, mortar with pestle material: porcelain size: 100 150 mm inner diameter exterior: glazed grinding surface: unglazed , hotplate top plate material: cast iron plate size: minimum 8 inch diameter power rating: 2000 w temperature range: ambient to 200 c minimum thermostatic temperature control: required power supply: 220 240 v ac, 50 hz, electric bunsen burner electrically operated energy regulator/ control knob operating temperature 800 c body: stainless steel power supply source: corded electric, supplied with a heavy-duty, heat-resistant, earth-grounded, 3-pin power cord (minimum length 1.2 meters). power consumption: between 350 and 500w power supply: 220-240 v ac, 50 hz, water distillation unit output capacity: 4 litres per hour (lph) ph value: 5.5 to 7.0 conductivity (raw water distillation):3.0 4.0 s/cm or less glassware material: borosilicate 3.3 glass (pyrex/duran equivalent) heating elements: silica enclosed quartz heaters or chromium-plated element variants power supply: 220 240 v ac, 50 hz / 60 hz, single phase automatic water level cut-off
Tender For purchase of basic engg lab equipments - basic engg dept lab equipments, digital balance, pestle with mortar, hotplate, electric bunsen burner, water distillation unit, deflection magnetometer apparatus, wheatstone bridge kit, ohms law verification kit
Tender For supply of adsorbent coating hydrated calcium sulphate , asbestos board 150 x 150mm 6 inch x 6 inch , capillary tubes closed at one end , heating mantle 1000 millilitre , heating mantle 500 millilitre , boat shaped mortar 8 inches long with pestle , boat shaped mortar 10 inches long with pestle , boat shaped mortar 14 inches with pestle , dissecting needle , nessler cylinder 1000 ml , nessler cylinder 250 ml , nessler cylinder 100 ml , pipette set calibrator set of 3 5 to 50 10 to 100 100 to 1000 , pipette tips 0 to 50 microliter , reagent bottles 100 ml , reagent sprayer glass camag , sieves no 100 , sieves no 200 , sieves no 250 , sieves no 300 , sieves no 350 , sieves no 50 , test tube holder , tlc precoated plates sil g size 10x20 cm , tripod stand , balance moisture analyser , desiccator 300 mm , pipette tips 0 to 1000 microliter , scalpel or razor blade , sieves no 04 , enamel tray 8 inch x 10 inch , pipette tips 0 to 200 microliter , scalpel or surgical blade handle
Tender For purchase of lab equipments for basic eng dept - purchase of lab equipments for baisc eng dept (physics and chemistry), digital balance itemcode: a001 weight 500g, accuracy 0.01g, top pan. tare function, caliberation- automatic external display type: led., joule s calorimeter itemcode: a005specifications:copper vessel, battery eliminator 3a, (2,4,6,8,10,12 v), tubular rheostat 20-3.3a, one way plug key, analog type dc ammeter (0 2a), voltmeter (0-5v), thermometer (alcohol), stop clock, ic regulated battery eliminator itemcode: a011specifications:ic regulated, input: 230v ac; output: 0-12v dc in steps of 2v; capacity: 1a or 2a., galvanometer itemcode: a012specifications:moving coil type, 30-0-30 scale, unbranded with bhel specification-sensitivitysensitivity, voltmeter itemcode: a013specifications:dc voltmeter; range 0 10 v, analog., ammeter itemcode: a014specifications:dc (0 - 2 amp), decade resistance box itemcode: a016specifications:resistance box 12 month warranty (dial type) -manganin coil- 2 dials, sonometer apparatus itemcode: a017specifications:sonometer with meter scale attached along with knife edge, tuning forks set 256, 384, 512 ranges, hammer, slotted weight - 500 gm each to a total of 3 kg. brass wire (5 m), travelling microscope itemcode: a018specifications:branded travelling microscope 0 200 mm horizontal and 0-150 mm vertical measurement, potentiometeritemcode: a019specifications:it features a 1-meter to 10-meter constantan/manganin wire stretched on a wooden or sunmica baseboard with a millimeter scale. it includes 4mm brass terminals, a pencil jockey for contact, wire options (10 wires), and a typical resistance range of 10-20 ohms, ideal for high-precision voltage measurements., rheostat itemcode: a021specifications:high-grade ceramic tube, oxidized resistance wire, 0.5a 5a, range 10 100 ., deflection magnetometer apparatusitemcode: a022specifications:deflection magnetometer apparatus with compass box and two short bar magnets, digital electronic balance /analytical balanceitemcode: a001/a007specifictions:load capacity: minimum,500 g readability: 0.01 g,linearity: 0.02g,display: lcd/led,tare function: required,top pan typepower supply: 220 240 v,ac, 50 hz, digital tds meter itemcode: a002specifictions:measuring range: 0 9990,ppm resolution: 1 ppm,display: lcdautomatic temperaturecompensation (atc): requiredwaterproof: minimum ip67 protectionpower source: battery, operated (button cell/aaa, digital ph meter benchtop model itemcode: a003specifications:ph type microprocessor/microcontrolle r ph range: 0 14resolution: 0.01 ph,accuracy: 0.05 ph or better combined ph electrode with temperature sensor two or three-point calibrationfacility temperature compensation type automatic display: lcdpower supply: 220 240 v ac, 50 hz warranty minimum 1 year, laboratory heating mantle (knitted glass yarn) itemcode: a004specifications:capacity: 500ml,temperature range: ambient to 350 c energy regulator/control knob:required power supply: 220-240 v ac,50 hz, mortar with pestle itemcode: a006specifications:material: porcelain size: 100 150 mm inner diameter exterior: glazed grinding surface: unglazed, hot plate itemcode: a008specifcations:top plate material: cast iron plate size: minimum 8 inchdiameter power rating: 2000 w temperature range: ambient o 200 c minimum thermostatic temperaturecontrol: required power supply: 220 240 v ac, 50hz., electric bunsen burner itemcode: a009specifications:electrically operated energy regulator/ control knoboperating temperature 800 c body: stainless steel power supply source: corded electric, supplied with a heavy-duty, heat-resistant,earth-grounded, 3-pin power cord (minimum length 1.2 meters). power consumption: between 350 and 500w power supply: 220 -240 v ac, 50 hz, water distillation unit itemcode: a010specifications:output capacity: 4 litres per hour (lph) ph value: 5.5 to 7.0conductivity (raw water distillation):3.0 4.0 s/cm or less glassware material:borosilicate 3.3 glass (pyrex/duran
Tender For corrigendum : tender for the supply of various equipments - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles, karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard, refrigerated centrifuge (bench top), bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples., gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25m (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25m),, "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 l recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:, matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water., ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubings, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 l, 20 l, 50 l, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each of, c8 = 250 4.6 5m c18 = 250 4.6 5m, cyano = 250 4.6 5m. amino = 250 4.6 5m, phenyl = 250 4.6 5m. silica = 250 4.6 5m., all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., ft-ir with atr & liquid cell, " hydraulic press with kbr die and pellet holder, suitable mortar pestle (dia 5-6 cm), suitable portable de humidifier to maintain 30- 60% rh, temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab., reference nist standard polystyrene film (0.3 mm) over the range of 3800 cm-1 to 650 cm-1., abbes r
Tender For purchase of equipments ( s.no 1 to s.no 08 ) for chemistry department - purchase of equipments, digital electronic balance /analytical balance load capacity: minimum 500 g readability: 0.01 g linearity: 0.02g display: lcd/led tare function: required top pan type power supply: 220 240 v ac, 50 hz , digital tds meter measuring range: 0 9990 ppm resolution: 1 ppm display: lcd automatic temperature compensation (atc): required waterproof: minimum ip67 protection power source: battery operated (button cell/aaa battery), digital ph meter benchtop model ph type microprocessor/microcontroller ph range: 0 14 resolution: 0.01 ph accuracy: 0.05 ph or better combined ph electrode with temperature sensor two or three-point calibration facility temperature compensation type automatic display: lcd power supply: 220 240 v ac, 50 hz warranty minimum 1 year, laboratory heating mantle (knitted glass yarn) capacity: 500ml temperature range: ambient to 350 c energy regulator/control knob: required power supply: 220-240 v ac, 50 hz, mortar with pestle material: porcelain size: 100 150 mm inner diameter exterior: glazed grinding surface: unglazed , hot plate top plate material: cast iron plate size: minimum 8 inch diameter power rating: 2000 w temperature range: ambient to 200 c minimum thermostatic temperature control: required power supply: 220 240 v ac, 50 hz, electric bunsen burner electrically operated energy regulator/ control knob operating temperature 800 c body: stainless steel power supply source: corded electric, supplied with a heavy-duty, heat-resistant, earth-grounded, 3-pin power cord (minimum length 1.2 meters). power consumption: between 350 and 500w power supply: 220-240 v ac, 50 hz , water distillation unit output capacity: 4 litres per hour (lph) ph value: 5.5 to 7.0 conductivity (raw water distillation):3.0 4.0 s/cm or less glassware material: borosilicate 3.3 glass (pyrex/duran equivalent) heating elements: silicaenclosed quartz heaters or chromium-plated element variants power supply: 220 240 v ac, 50 hz / 60 hz, single phase automatic water level cut-off