Get complete information related to latest Scada Software Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Scada Software Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Scada Software Tenders.
Tender For supply, installation, testing and commissioning of phase wire and street light and vairious electrical equipment needed for implementation of budget announcement 2025-26 - providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in, led street light fixture with minimum lumen output 5600 lm, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra )(d)wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap-offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be point to point (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)floor mounted panel sh
Tender For bid to ras corrigendum : supply of degn sup inst test comm of water management system d d -pump set-minimum head 30 mtrs , power db with suitable for 1 working 1 stand by pumps , power db with suitable for 1 working 2 stand by pumps , plc hmi control panel with smps 1 working 1 stand by pumps , plc hmi control panel with smps 1 working 2 stand by pumps , inline electromagnetic flowmeter , smart pressure transmitter range 0-16 bar , pressure switch range 0-10 bar , pump set-minimum head- 15 mtrs , vertical pump set-minimum head- 15 mtrs , power db with suitable for 2 working 3 stand by pumps , plc hmi control panel with smps - 1 working 1 stand by pumps , plc hmi control panel with smps - 3 working 2 stand by pumps , pressure switch, range 0-10 bar , 1 pump set-minimum head- 10 mtrs , plc hmi control panel with smps for 1 working 1 stand by pumps , plc hmi control panel with smps for 1 working 2 stand by pumps , smart pressure transmitter range 0-16 , pump setminimum head- 22 mtrs , plc hmi control panel with smps for 1 working1 stand by pumps , ultrasonic hydrostatic level transmitter , magnetic float type level sensor , motorized valve with on off control 40nb , motorized valve with on off control 50nb , motorized valve with on off control 65nb , motorized valve with on off control 80nb , armoured cable 1. 1kv grade 3 core x 2. 5 sq. mm , armoured cable 1. 1kv grade 3 core x 4 sq. mm , armoured cable 1. 1kv grade 3 core x 6 sq. mm , cable tray , plc remote control panel with smps and suitable qty of relay boards , control panel with master plc ups , fiber optic cable 4 pair pvc , signal converter rs485 to fiber optic , signal converter ti port to fiber optic converter , cat 6 cable with pvc conduit , industrial grade 8 port lan switch , control room server with scadasoftware 2000 tags licensed copy , plc programming software licensed copy with laptop , installation testing and commissioning of complete system ) /bid number: gem/2026/b/7268901 * /dated: 05-03-2026 & & / bid document1 / 42
Tender For (sh -sitc of automation and management system with microprocessor-based control panel, online monitoring and wireless connectivity with scadasoftware at gk-1
Tender For auction sale of others - scrap miscellaneous item(1)main & stand by computer each processor consisting of pentium iii based on latest 600 mhz 32 bit 128 mb ram, 20gb hdd 52 cd drive (writable) 1.44 mb fdd, 104ms window compatible key board & mouse, 15" colour svga monitor with network card & tcp/ip protocol,2nos(2)communication server pentium ii based pc or latest 600 mhz 32bit 128 mb ram, 20 gb hdd, 52xcd drive (writable) 1.44mb fdd,104 ms window compatible key board & mouse, 15" colour svga monitor with network card & pcp/ip protocol.,2nos(3) man & stand by work station each consisting of pentium iii based pc or latest with minimum 128mb,ram 20 gb hdd, 52xcd drive 1.44 mb fdd & speed 600 mhz along 3nos. 19" svga fully graphic colour vdus with each machine will have it separate alphanumeric key board & mouse b67 network card & tcp/ip support multimedia kit should be available to give distinguishing alarm to tpc with network card & pcp/ip protocol,5nos(4) laser coloured data logging printer suitable for printing a3 size paper (with minimum 600x3000 dpi resolution),2nos(5)indication switching pannel to display ups alarm/status,1no(6)master clock & slove clock,3nos(7)front end driver (display),3nos(8)2x5 kva dual load sharing ups system,1no(9)server computer & fep computer,4nos(10)work station computer,4nos(11)ac modem,4nos(12)dot matrix printer,2nos(13)scadasoftware for dual hot stand by stand by system(cd)(1-13)location-sse/rc/ddu,note-pc-17nos.,dot matrix printer-02nos,colour printer-02nos,electronic device-06nos,cloc-03nos,cd-01no,total weight of electronics items-473kg,ups-1 set, total wt-375kg(ferrous-353kg,non-ferrous-22kg)
Tender For corrigendum : supply of supply of siemens plc and accessories for main condenser ball cleaning filter pah system . specifications as per annexure-1,2. , reconfiguration of items in sl 1 , supply of siemens plc and accessories for tdfp condenser ball cleaning filter pah system . specifications as per annexure- 3,4. , reconfiguration of items in sl 3 , supply of siemens plc and accessories for main condenser debris filter pbb system, specifications as per annexure-5,6. , reconfiguration of items in sl 5 , supply of siemens plc and accessories for tdfp condenser debris filter pbb system, specifications as per annexure-7,8. , reconfiguration of items in sl 7 , supply of siemens plc and accessories for solid radioactive waste incinerator kph system, specifications as per annexure-9,10,11. , reconfiguration of items in sl 9 , supply of siemens plc and accessories for solid radioactive waste storage kpe system, specifications as per annexure-12,13,14,15. , supply of scadasoftware for human machine interface for solid radioactive waste storage kpe system , pc slash laptop for installing the scadasoftware , reconfiguration of items in sl 11
Tender For sh- supplying, installation, testing and commissioning of dewatering system automation and management system with microprocessor based control panel, online monitoring and wireless connectivity with scadasoftware at basement of thyagraj stadium