Get complete information related to latest Scada System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Scada System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Scada System Tenders.
Tender For supply of set of spares for ckd make prv items suitable for aal make vcb 1. ckd prv with gauge , input & output bolts with washers, to suit aal vcb, ckd make asper part no. w-2000-10-w-m1. 2. ss input pipe with base plate for ckd prv suitable for aal vcb to m/s solutions automation part no: stap-3/8. 3. air gauge with metal adaptor, used at air tank in panel as per part no: g49d-6-10 p. make: ckd only. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : integration of residential btu meters for the upcoming buildings with the existing scadasystem via the modbus tcp/ip network, along with required accessories in gift city
Tender For bid to ras supply of ceiling speakers , column array speakers , amplifier for ceiling speakers , amplifier for column array speakers , digital signal processor , boundary layer microphones , on off button for boundary layer microphones , switch box for boundary layer microphones , ceiling tile microphone array , main display , side display , annotation panel , cable manager for table , hdmi switcher , hdmi splitter , hdmi extender , usb tx multiformat switcher , usb rx multi format switcher , usb data matrix switch , ptz camera , speaker tracking camera , hdmi to usb capture card , voice tracking device , control system with touch controller , network switch , room scheduler , pdu with humidity and temperature sensor , ceiling mount document scanner , equipment rack , ups 10 kva ups with 60 min backup , ups 3 kva ups with 60 min back up , acoustic door with fitting laminate and door frame , chair , hot and cold ac 2 ton , room air purifier , bio metric door access control , auto fire suppression system for av rack , high quality wireless keyboard and mouse , led surface recessed mounted panel with luminous web , 12 channel signal dimmer controller , 12 channel controller , display keypad panel for workstations , network router for automation system , sitc supply installation testing and commissioning , acoustic wall paneling , acoustic false ceiling , wooden conference table , executive chair , acoustic carpet flooring , power supply for lighting control network , lighting control communicaiton gateway
Tender For supply of ultrasonic level measurement system spares for scadasystem of bmc - dual channel ultrasonic level transmitter, ultrasonic level sensor units
Tender For corrigendum : erection of 01 nos 33kv rewan bay with supply of material, integration and remote gateway work at 220kv ss bangra under etd jhansi - erection of following different type main and auxiliary structur, columns, beams, peaks, masts ets. suitable for placing of kv equipments., main structure & auxiliary structure., erection of following equipments as per instruction manual of various equipments and technical specification including shifting of material / equipments from sture to erection site including all other associated work to complete the job satisfactorily., 36kv v.c.b., 36kv bi, 36kv li, 36kv ct, ct junction box, cutting. strenghtening. bending. laying 700mm. below in side ground and above ground og following size of ms flat for earthing of main and auxiliary structure. equipment structure t/f body and its material etc. including welding with main earth mat and with object to be earthing / excavation of trenches its back filling., 75x10mm ms flat, 50x6mm ms flat, 25x10mm ms flat, provinig, fixing & installation of glow sign board (as per sample) of size 8ft x 6ft for updated substation single line diagram duly checked & verified by concerned ae, to be fixed in control room building of substation with all other associated work to complete the job satisfactorily as per drawing and technical specn. of upptcl, the glow sign board illumminated using led tube light in sufficient quantity. the board shall be made of acrylic sheet of suitable thickness and color and shall be provided with back support frame & fixing arrangement with wall., interconnection of equipments and bus bar including cutting. bending of conductor and jumping, clamping along with all other associated work to complete the job satisfactorily as per drawing and technical specn., equipment jumper with 1xmoose, 10mtr, 33kv, bus bar jumper with 1xmoose, 10mtr, 33 kv, 6m, laying of following sizes of control cable in the cable trench from control relay panel to various equipments / marshalling boxes and jb etc. in switchyard as per cable schedule., 2c x 2.5 sq mm. unarmoured., 4c x 2.5 sq mm. unarmoured., 6c x 2.5 sq mm. unarmoured., termination of 2cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 4cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 6cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., preparation of cable schedule and case interconnection diagram in between relevant panel,cb,ct,pt,etc.., providing and fixing of led street light luminaries, single piece aluminum body suitable for 120 watt having lumen output not less than 10,000 nom on 9 mtr. long stp/substation main structure column with g.1. pipe bracket complete in all respect cat. a philimps bajaj/ crompton/havells or equivalent make including cost of g.1. pipe brackets and all related accessories., supply, supply of single tension fitting suitable for acsr moose as per sample, supply of single suspension fitting suitable for acsr moose as per sample, supply of 33kv ct clamps suitable for acsr moose as per sample, supply of 36kv isolator jaw as per sample, supply of copper bond 16x500mm, supply of 33 kv isolator clamps suitable for acsr moose as per sample, intregration & remote gateway work, supply of required material with installation and intregration of new 33 kv line control & relay panel with iec -61850 compliant ied with existing automation system and addition of bay into remote gateway & data validation work.
Tender For corrigendum : erection of 01 nos 33 kv birdha bay with supply of material, integration and remote gateway work at 220kv ss birdha under etd jhansi - erection of following different type main and auxiliary structur, columns, beams, peaks, masts ets. suitable for placing of kv equipments., main structure & auxiliary structure., erection of following equipments as per instruction manual of various equipments and technical specification including shifting of material / equipments from sture to erection site including all other associated work to complete the job satisfactorily., 36kv v.c.b., 36kv bi, 36kv li, 36kv ct, ct junction box, cutting. strenghtening. bending. laying 700mm. below in side ground and above ground og following size of ms flat for earthing of main and auxiliary structure. equipment structure t/f body and its material etc. including welding with main earth mat and with object to be earthing / excavation of trenches its back filling., 75x10mm ms flat, 50x6mm ms flat, 25x10mm ms flat, provinig, fixing & installation of glow sign board (as per sample) of size 8ft x 6ft for updated substation single line diagram duly checked & verified by concerned ae, to be fixed in control room building of substation with all other associated work to complete the job satisfactorily as per drawing and technical specn. of upptcl, the glow sign board illumminated using led tube light in sufficient quantity. the board shall be made of acrylic sheet of suitable thickness and color and shall be provided with back support frame & fixing arrangement with wall., interconnection of equipments and bus bar including cutting. bending of conductor and jumping, clamping along with all other associated work to complete the job satisfactorily as per drawing and technical specn., equipment jumper with 1xmoose, 10mtr, 33kv, bus bar jumper with 1xmoose, 10mtr, 33 kv, 6m, laying of following sizes of control cable in the cable trench from control relay panel to various equipments / marshalling boxes and jb etc. in switchyard as per cable schedule., 2c x 2.5 sq mm. unarmoured., 4c x 2.5 sq mm. unarmoured., 6c x 2.5 sq mm. unarmoured., termination of 2cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 4cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 6cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., preparation of cable schedule and case interconnection diagram in between relevant panel,cb,ct,pt,etc.., providing and fixing of led street light luminaries, single piece aluminum body suitable for 120 watt having lumen output not less than 10,000 nom on 9 mtr. long stp/substation main structure column with g.1. pipe bracket complete in all respect cat. a philimps bajaj/ crompton/havells or equivalent make including cost of g.1. pipe brackets and all related accessories., supply, supply of single tension fitting suitable for acsr moose as per sample, supply of single suspension fitting suitable for acsr moose as per sample, supply of 33kv ct clamps suitable for acsr moose as per sample, supply of 36kv isolator jaw as per sample, supply of copper bond 16x500mm, supply of 33 kv isolator clamps suitable for acsr moose as per sample, intregration & remote gateway work, supply of required material with installation and intregration of new 33 kv line control & relay panel with iec -61850 compliant ied with existing automation system and addition of bay into remote gateway & data validation work.
Tender For supply of cpu card for tru synergy system as per scc , cxm card synergy system rtu as per scc , ios card synergy system rtu as per scc , di card for synergy scadasystem as per scc , do card for synergy scadasystem as per scc , ai card for synergy scadae70aib001 as per scc , ao card synergy rtu as per scc , backplane 5 io slots synergy system rtu as per scc , rack 19 inch synergy system rtu as per scc , network switch 8port synergy system rtu as per scc , 24v dc power supply module e70psu001 as per scc , huskey rtu 6049e70 mini as per scc , 24v dc power supply module e70psu001as per scc
Tender For corrigendum : upgradation of scadasystem for synchronized operation of all electromechanical equipments along with requisite license software both engineering and operating license for 6 mld stp alluchibagh 2.21 mld stp rajbagh
Tender For corrigendum : upgradation of scadasystem for synchronized operation of all electromechanical equipments along with requisite license software both engineering and operating license for 6 mld stp alluchibagh 2.21 mld stp rajbagh
Tender For design, drawing, supply, erection, testing and commissioning of 25 kv (ac) ohe system, modification of ssp with provision of scadasystem electrical general works includes illumination of yard/ buildings/pathway by 30 20 mtr high masts for coal t