Get complete information related to latest Scaffolding Pole Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Scaffolding Pole Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Scaffolding Pole Tenders.
Tender For supply of brass gland with stud and nut part no. ngeb-024 , circlip for plug socket set of 4 part no. ngeb-036 , heavy duty screw assembly complete with handle bush lock for 200 amps plug and socket part no. ngeb-011 oblique 3 , 300amps,3 pole off-load isolator rev with handle axel and bush part no. ngeb-010 , plug only 200 amps., 4 pin complete part no. ngeb -011 oblique 2 , potential transformer 100va moulded type part no. ngeb-025 , only keeper for dmc moulded socket insulator of 200 amps plug and socket. ngeb -014 oblique a , only keeper for dmc moulded plug insulator of 200 amps plug and socket. ngeb - 012 oblique a , dmc moulded plug insulator w.o.pin for 200 amps plug and socket part no. ngeb -012 , dmc moulded socket insulator w.o.pin for 200 amps plug and socket part no. ngeb -014 , i. s. pilot panel intrinsically safe part no. ngeb -09 , earth leakage relay non self reset type, current range- 100 ma to 750 ma with time delay- 0.1 to 1 sec. part no. ngeb-007 , brass pin for plug set of 4 pin 200 amps part no. ngeb -013 , brass pin for socket set of 4 pin 200 amps part no. ngeb -015 , pilot relay 2c o mpc 12 volts dc pt, no. ngeb-041 , dmc moulded hrc fuse base for power pt. no. ngeb-030 , only thermal overload relay range 4.5a to 7.5a suitable for mn12 relay range 135a-225a without ct ngeb 006-1
Tender For supply of equipment items - dc motor:type: dc shunt motor (dismantling model) power: minimum 0.5 hp voltage: 220 v dc speed: 1500 rpm poles: 4 pole construction: laminated stator salient poles accessible armature features: cut section / open type suitable for dismantling and reassembly, hydraulic cylinder: bore diameter: 50 mm stroke length: 250 mm working pressure: 160 bar cylinder tube: honed steel piston rod: hard chrome plated seals: standard industrial seals end caps: steel supply: mounted on training base suitable for dismantling and inspection, hydraulic operated directional control valves (dcv):type: manual spool type dc valve configuration: 4/2 way size: ng06 (cetop 3) rated pressure: 210 bar flow capacity: 20 40 lpm body: hardened steel / cast steel spool: ground and hardened ports: clearly marked (p, a, b, t) supply: mounted on training plate suitable for dismantling and study, bearing with shaft assembly :type: dismantling and assembly teaching unit shaft diameter: 30 mm shaft material: en8 steel bearings: deep groove ball bearing (6205 / 6206) housing: cast iron locking arrangement: circlips lock nuts end covers mounting: bench-mounted / frame-mounted unit, coupling unit using driving and driven shafts using plummer block bearing unit :the plummer block housing material: cast iron (grade fg 200 or equivalent). type: sng or snl series (split-type housing). sealing: felt seals or v-ring seals (to demonstrate lubrication retention). lubrication: provided with a grease nipple at the top center for manual lubrication practice. the bearing type: self-aligning ball bearing (1200 series) or spherical roller bearing (22200 series). bore diameter: standard 25mm or 30 mm. shafting and coupling shaft material: ground carbon steel (en8 or en9) for high surface finish. coupling type: flexible coupling: to demonstrate the bearings ability to handle slight misalignment. rigid flange coupling: to demonstrate traditional direct connection. driving/driven setup: one shaft connected to a small electric motor (driving) and the other to a brake drum or load (driven).
Tender For supply of power control system 63 ampere 4 pole 25 ka rated voltage: 415 v, 50hz ac calibrated up to 50 degree celsius with integrated pad lock system with spreader link 8 numbers & ss nut bolt 4 pair as per is/iec: 60947 part-2:2003 or latest. make-hager/havells/ legrand/abb/similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply, erection, testing & commissioning of lt panel consisting of 400a 50ka 4 pole microprocessor based mccb - 02 nos as incoming , 200a/250a 36ka 4 pole microprocessor based mccb-03 nos, 63a 36ka 4 pole microprocessor based mccb-02 nos and 63a 10ka dp 2pp mcb - 02nos as outgoing, all mccbs shall be with rotary switch, with voltmeter,ammeter, led indicator lamp,cu. bus bar , neutral link, earth bar, spreader link, lock and key feature arrangement cable gland etc. with suitable sheet steel enclosure conforming to cege/grc's specification no. ser/elec/gs/description/ltpanel/1/rev-0/mar2024 or latest.minimum size of panel 1800 mm (h)x 2400mm (l) x 600 mm(d). [ warranty period: 30 months after the date of delivery ] ]
Tender For supply, installation, testing and commissioning of phase wire and street light and vairious electrical equipment needed for implementation of budget announcement 2025-26 - providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in, led street light fixture with minimum lumen output 5600 lm, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra )(d)wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap-offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be point to point (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)floor mounted panel sh
Tender For corrigendum : supply of electrical spare parts required for streetlights and town panchayat buildings. - 4 feet flourescent tube light, 40w copper choke, 40w tube light starter, 36w / 40w tubelight electronic choke, tube light side lock holder, insluation gum tape roll - isi, 1/18 vir copper wire [1/44] [90mtr], 3/20 cts copper wire [3/36] [90mtr], 7/20 cts copper wire [7/34] [90mtr], 7/16 cts copper wire [7/67] [90mtr], 19/16 cts copper wire [19/51] [90mtr], 1.5 sq.mm 3 core copper cable, 2.5 sq.mm 3 core copper cable, 4 sq.mm 3 core copper cable, 6 sq.mm 3 core copper cable, 10 sq.mm 3 core copper cable, 16 sq.mm 3 core copper cable, 36w 4pin lamp holder, 36w lamp clip, 24w t5 holder, led fitting top protection glass - street light, led fitting top protection glass - flood light, 20 / 25 mm 1 no gi bend pipe, with 2nos of pole clamps with bolts and nuts, 32 / 40 mm 1 no gi bend pipe, with 2nos of pole clamps with bolts and nuts, 6amps to 32 amps sp mcb, 40amps 2pole isolator, 63amps 4pole isolator, 32a d.p switch, mcb box, fuse unit 16 amps 240v, fuse unit 32 amps 415v, fuse unit 63 amps 415v, fuse unit 100 amps 415v (heavy duty), fuse unit 200 amps 415v (heavy duty), fuse unit 300 amps 415v (heavy duty), fuse unit 400 amps 415v (heavy duty), fuse unit 500 amps 415v (heavy duty), main switches spn 32 amps, main switches tpn 32 amps, main switches tpn 63 amps, main switches tpn 100 amps, main switches tpn 315 amps, 63a 4pmc changeover switch, 100a 4pmc changeover switch, automatic on/off street light timer switch with 24hrs 7 days programable digital timer clock, 40 amps 4 pole contactor with coil, mcb switch and connector fully wired with all accessories, street light meter/main box with wooden board, main switch, fuse carrier fully wired with all accessories, electronic 7 days 24 hrs programable ditial timer clock, 63 amps 4 pole contact with coil, 220v - 250v contactor coil, power capacitor, 9w led bulb, 15w led bulb, 30w led lamp, 24w t5 power saver lamp, 2x24w t5 power saver choke, 36w 4 pin non retrofit type cfl power saver lamp, 36w 4 pin non retrofit type cfl power saver choke, 20w high bright led 4 feet light, 20w led power saver street light fitting, 25w led power saver street light fitting, 30w led power saver street light fitting, 36w led power saver street light fitting, 50w led power saver street light fitting, 60w led power saver street light fitting, 72w led power saver street light fitting, 90w led power saver street light fitting, 120w led power saver street light fitting, 100w led power saver flood light fittings, 150w led power saver flood light fittings, 200w led power saver flood light fittings, 40w all-in-one solar led street light fittings, 60w all-in-one solar led street light fittings, 80w all-in-one solar led street light fittings, 18w to 25w led chip board, 30w to 36w led chip board, 45w to 60w led chip board, 72w to 90w led chip board, 120w to 200w led chip board, 18w to 25w led heavy duty electronic driver, 30w to 36w led heavy duty electronic driver, 45w to 60w led heavy duty electronic driver, 72w to 90w led heavy duty electronic driver, 120w to 200w led heavy duty electronic driver, 10 kv surge protector, 48` ceiling fan with all accessories, d.o.l motor starter up-to 10 hp, 10metre hot dip galvanised octogonal pole with round ring arm and 4nos of strong 5feet anchor bolts, templates, and nuts etc.. complete set, 1 hp to 3hp single phase control panel with contactor, relay, auto-start preventor, volt meter, amps meter, etc.. complete in a suitable powder coated enclosure., 5 hp to 7.5hp three phase fasd - auto-start / dry run protection control panel with contactor, relay, auto-start preventor, volt meter, amps meter, etc.. complete in a suitable powder coated enclosure., 10 hp to 25hp three phase fasd - auto-start / dry run protection control panel with contactor, relay, auto-start preventor, volt meter, amps meter, etc.. complete in a suitable powder coated enclosure., g.i swaged tubler 6 me