Get complete information related to latest Scaffolding Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Scaffolding Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Scaffolding Tenders.
Tender For bid to ras corrigendum : supply of various fabrication items for bm d d - st010260011-journal head liner support , st010260008- journal head liner 1 , st010260009-journal head liner 2 , st010260010-journal head liner 3 , st010260048-guard for journal upper bearing housing , st010160010- tension roll assembly for gravimetric feeder , st010160051-take up screw for gravimetric feeder , st010160003-weigh span roller assy , st010160088- head pulley bushing - gravimetric feeder , st010160050-bolt for gravimetric feeder door , st010160101-coc guide block , st010160012-take up block for take up pulley for gravimetric feeder , st010160014-head pulley bearing end cover , st010160016-head pulley bearing cover of gravimetric feeder , st010140264-2.5 mm sheet for sealing for id fan impeller , st010160102-gate rack l.h of 36 inch raw coal gate , st010160103-gate rack r.h of 36 inch raw coal gate , st010140265-taper pin for pa and fd fan casing , st010470348-modified sector plate adjustment system for raph 31.5vimt , sc110440038-m16 x 1000 mm stud full threaded with two nut of class 8.8 gr , co110140169-high tensile studs size- m30 x 1000. grade- 8.8 class. , co110140167-m10 x 1000 mm stud full threaded with two nut of class 8.8 gr , co110140168-m12 x 1000 mm stud full threaded with two nut of class 8.8 gr , sc110440002-m24x200 stud bolt astm a193 gr. b7 and 2 nuts astm a194 gr. 2h , sc110440035-stud bolt m24x90 of grade astm a193 gr b7 and 2 nuts astm a194 gr. 2 h , co110150140-plate washer m12. id-13mm. od-30mm. thickness-2mm , co110150141-plate washer m16. id- 17mm. od-40mm. thickness-2.5mm , sc310270055-mild steel scaffolding gratings as per drawing , st010430399- peep hole door , st010390317-bah lhs chute-stainless steel , st010390318-bah middle chute-stainless steel , st010390319-bah rhs chute-stainless steel , co030190063-straight ss protection shield , co030190062-clamp for protection shield , co030190064-expansion sleeve for protection shield //bid details 2 / 35
Tender For corrigendum : supply of supply of hotline maintenance tools accessories for 765 kv by 400 kv ss of sr i and wr ii powergrid d d - hotline tools for live line maintenance for tl for sr-i , hotline tools for live line maintenance of 765 kv switchyard for sr-i , 765 kv insulated aerial work platform or bucket truck for sr-i , hands on training for sr-i , annual maintenance contract for sr-i , insulated scaffolding system 15 meter for wr-ii , insulated scaffolding system 18 meter for wr-ii , conductive suit with static belt for wr-ii , conductive socks suitable for 765 or 400 kv switchyard for wr-ii , conductive boots suitable for 765 or 400 kv switchyard for wr-ii , conductive gloves suitable for 765 or 400 kv switchyard for wr-ii , safety belt with pole strap for wr-ii , insulated rope 181 mtr or 600ft length each for wr-ii , light weight pulleys compatible to scaffolding for wr-ii , endless nylon slings for wr-ii , endless nylon slings compatible to scaffolding for wr-ii , tool buckets compatible to scaffoldin for wr-ii , micro-ammeter analog for wr-ii
Tender For corrigendum : supply of required materials for solid waste management unit in halakurki gp of badami taluk - cement (badami), tmt steel (badami), sand (badami), roof sheet, rubble stone (badami), paint (badami), m s truss, jelly(40 mm), concrete bricks, bricks ( badami), jelly (20mm)
Tender For corrigendum : supply of required materials for solid waste management unit in neerbudihal gp of badami taluk - pan (badami), boulders (badami), cement (badami), tmt steel (badami), sand (badami), roof sheet, rubble stone (badami), paint (badami), m s truss, msgate (badami), jelly(40 mm), concrete bricks, bricks ( badami), jelly (20mm)
Tender For annual maintenance estimate for water supply in sector 15a hisar (2025-2026). ` repairing and maintenance of overhead tank including scaffolding at boosting station sector 15 a hisar and all other works contingent thereto`. a/c rs. 1.91 lacs
Tender For e-quotations are invited for ascertaining rate of items for preparing estimate of construction of jsfc godown 1000 mt, udhwa. - design, supply, fabrication, transportation, and installation of truss-less self-supported arch roofing system over the specified warehouse structure. all materials, consumables, labor, tools, machinery, and incidental items shall be included in the quoted price.________________________________________1. site details: project type: warehouse roofing span (clear): 21.80 meters arch rise: 3.00 meters (span/5) length of shed: 46.50 meters no. of bays: 1 eave height: 5.60 meters (approx.)________________________________________2. roofing system requirements: type: truss-less (self-supported arch type) roofing system design: to be structurally stable without any intermediate truss or support, suitable for clear span of 21.80 meters and arch rise of 3.00 meters roof coverage area: approx. 1,013.7 sq.m (21.80 m 46.50 m)________________________________________3. material specifications: sheet material: color coated colorbond zincalume steel coating type: az150 (al-zn alloy coating, 150 g/m total on both sides) standard compliance: astm a 792 base metal thickness (bmt): 1.10 mm total coated thickness (tct): 1.075 mm width of coil: 912 mm to 1010 mm tolerance: 2 mm________________________________________4. additional requirements: installation: complete laying and fixing of roofing with overlaps and arching to specified dimensions using hydraulically operated mobile forming machinery. fasteners: high tensile, corrosion-resistant self-drilling screws with epdm washers to be used as per manufacturer recommendations. sealants/consumables: all sealants, fasteners, insulation pads, edge closures, etc., required to ensure weather-tight performance shall be included. workmanship: roofing system shall be free from dents, scratches, warping. finish should be smooth and uniform in color. drainage/gutters: (specify if required)________________________________________5. design & load considerations: wind load: as per is 875 part 3 (latest revision) live load & dead load: as per is 875 part 2 seismic consideration: as applicable per is 1893 deflection limits: as per is 800________________________________________6. quality control & inspection: all material to be accompanied by manufacturers test certificates. the roofing system shall be inspected and approved before and after installation by the engineer-in-charge.________________________________________7. warranty: minimum 10 years warranty on material for corrosion resistance and color stability., supplying & installation of single turbo ventilators 2300 cfm, size 24", aluminum construction with skylight of 2mm thick size 2 x 07 ft. - with complete fixing accessories, supplying & installation of hangers / clamps (for light hanging purpose).all materials, consumables, labor, tools, machinery, and incidental items shall be included in the quoted price., supply, installation, testing & commissioning of weighbridge. platform size 12.0 x 3.0 meter max. capacity 60 mt. type of platform fully welded modular type weighbridge main u-beam 300 mm x 140 mm - u beam (e 350 grade h t plate) cross support 16 mm thick plate between two main long beam top plate 8 mm top plate with anti-skid strips foundation frame 100 mm x 50 mm long frame with fully welded 350 mm x 350 mm x 16 mm plane plate border frame 100 mm x 50 mm - both side heavy duty frame with side wall mounting load cells ms plates 150 mm x 150 mm x 16 mm - load cell top & bottom plate joint & assembly main beam, cross support & top plate completely welded to each other. guide rail round pipe based side frame - 100 mm - both side fasteners as per required & is standard paint 2 coat of ant-corrosive primer and 2 coat enamel paint material all material will be is 2062 standard material list weighbridge platform structure- - 01 no. u-beam type modular orthotropic all material will be is 2062
Tender For e-quotations are invited for ascertaining rate of items for preparing estimate of construction of jsfc godown 1000 mt, mandro - design, supply, fabrication, transportation, and installation of truss-less self-supported arch roofing system over the specified warehouse structure. all materials, consumables, labor, tools, machinery, and incidental items shall be included in the quoted price.________________________________________1. site details: project type: warehouse roofing span (clear): 21.80 meters arch rise: 3.00 meters (span/5) length of shed: 46.50 meters no. of bays: 1 eave height: 5.60 meters (approx.)________________________________________2. roofing system requirements: type: truss-less (self-supported arch type) roofing system design: to be structurally stable without any intermediate truss or support, suitable for clear span of 21.80 meters and arch rise of 3.00 meters roof coverage area: approx. 1,013.7 sq.m (21.80 m 46.50 m)________________________________________3. material specifications: sheet material: color coated colorbond zincalume steel coating type: az150 (al-zn alloy coating, 150 g/m total on both sides) standard compliance: astm a 792 base metal thickness (bmt): 1.10 mm total coated thickness (tct): 1.075 mm width of coil: 912 mm to 1010 mm tolerance: 2 mm________________________________________4. additional requirements: installation: complete laying and fixing of roofing with overlaps and arching to specified dimensions using hydraulically operated mobile forming machinery. fasteners: high tensile, corrosion-resistant self-drilling screws with epdm washers to be used as per manufacturer recommendations. sealants/consumables: all sealants, fasteners, insulation pads, edge closures, etc., required to ensure weather-tight performance shall be included. workmanship: roofing system shall be free from dents, scratches, warping. finish should be smooth and uniform in color. drainage/gutters: (specify if required)________________________________________5. design & load considerations: wind load: as per is 875 part 3 (latest revision) live load & dead load: as per is 875 part 2 seismic consideration: as applicable per is 1893 deflection limits: as per is 800________________________________________6. quality control & inspection: all material to be accompanied by manufacturers test certificates. the roofing system shall be inspected and approved before and after installation by the engineer-in-charge.________________________________________7. warranty: minimum 10 years warranty on material for corrosion resistance and color stability., supplying & installation of single turbo ventilators 2300 cfm, size 24", aluminum construction with skylight of 2mm thick size 2 x 07 ft. - with complete fixing accessories, supplying & installation of hangers / clamps (for light hanging purpose).all materials, consumables, labor, tools, machinery, and incidental items shall be included in the quoted price., supply, installation, testing & commissioning of weighbridge. platform size 12.0 x 3.0 meter max. capacity 60 mt. type of platform fully welded modular type weighbridge main u-beam 300 mm x 140 mm - u beam (e 350 grade h t plate) cross support 16 mm thick plate between two main long beam top plate 8 mm top plate with anti-skid strips foundation frame 100 mm x 50 mm long frame with fully welded 350 mm x 350 mm x 16 mm plane plate border frame 100 mm x 50 mm - both side heavy duty frame with side wall mounting load cells ms plates 150 mm x 150 mm x 16 mm - load cell top & bottom plate joint & assembly main beam, cross support & top plate completely welded to each other. guide rail round pipe based side frame - 100 mm - both side fasteners as per required & is standard paint 2 coat of ant-corrosive primer and 2 coat enamel paint material all material will be is 2062 standard material list weighbridge platform structure- - 01 no. u-beam type modular orthotropic all material will be is 2062
Tender For construction of scaffolding structures for structural safety integrity and gpr tests to be conducted at dam site under north koel reservoir project jharkhand