Web Analytics Made Easy - StatCounter

Scientific Journal Tenders

Get complete information related to latest Scientific Journal Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Scientific Journal Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Scientific Journal Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45335075 Due date: 05 Jun, 202605 Jun, 2026 NA
Tender For srphc82281240-coronary drug eluting stents with (1) stent on cobalt chromium alloy or platinum chromium alloy. (2) stent with coating of polymer carrier for active drug ( sirolimus everolimus or zotarolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.5mm to 4mm and length of the stent should be 12mm to 48mm. (4) the strut thickness should be 91 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapidexchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval should be enclosed in the tender bid. (9) the long term efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals. (10) the documents related to the efficacy and safety of the stent should be only for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of thestent to a major government institute. unit:no [ warranty period: 30 months after the date of delivery ] ]

CTN :45284517 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For supply of drug eluting stent -sirolimous drug with biodegrable polymer on cobalt chromium platform with active coating. size ranging from length 08 mm to 48 mm and width 2.25 mm to 5.0 mm. the quoted stent to be at least dcgi approved and three years efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented/published in peer reviewed scientific journals. the documents pertaining to the efficacy and safety of the stent should be enclosed for the brand that is offered in the tender bid. replacement warranty against any manufacturing defect noted onthe o.t. table. the original company brochure mentioning the range of sizes (diameter & length) should besubmitted along with tender. [ai(2026-27), item code-no: s-62066, sl no.2010] ]

Central Government/Public Sector

CTN :45281472 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For supply of printing items d d - allocation register 250 page , journal register 250 page both side printing , printed file cover , bill register 200 page double side printing , challan book total 300 pages included carbon copy pink yellow white , cropwise weekly irrigation report 150 pages per book , cl cpl rh form 100pages per pad a4 size , d.p.r. book agri total 300 pages included carbon copy , earned leave form 100 pages per pad a4 size , epf advance refundable form 100 pages per pad a4 size , bill sanction or adjustment form 100 pages per pad a4 size , field diary mech 200 pages , gate pass book out total 300 pages included carbon copies , gate register security vehicle both side print 200 pages , register for gate passes out both side print 200 pages , joining report form 100 pages per pad a4 size , leave order pad 100 pages per pad a4 size , leave encashment form 100 pages per pad a4 size , material requistion book total 400pages included carbon copies , medical reimbursement form , mt note 250 pages included 5 copies , perk form 100 pages per pad a4 size , release order book total 500 pages included 5 copies , register ta bill payment 250 pages , stock register 500 page , stock register 300 page , weighment sheet book total 300 pages included carbon copy , weekly irrigation data for canal irrigation 150 pages , payment voucher pad 100 pages , sample coupon for grower total 300 pages included copies , budget monitor 100 pages , weakly rainfall irrigation and crop condition 150 pages , stock register plant 400 pages , processing record register 200pages , epf non refundable 100 pages per pad 2 set , order for work form 100 pages per pad a4 size , indent book material requistion slip total 400 pages included carbon copies , log book tractor 200 pages , pol rv book total total 300pages included carbon copy , stock ledger 200 page , cpi book total 400 pages 1st copy is pink , dak receipt register 300 page legal size , dak dispatch register 300 page legal size , medical bill register 250 page , tour report 100 page per pad , seed fertilizer pesticide register 250 pages

Central Government/Public Sector

CTN :45254443 Due date: 03 Jun, 202603 Jun, 2026 NA
Tender For srphc82281240-coronary drug eluting stents with (1) stent on cobalt chromium alloy or platinum chromium alloy. (2) stent with coating of polymer carrier for active drug ( sirolimus, everolimus or zotarolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.5mm to 4mm and length of the stent should be 12mm to 48mm. (4) the strut thickness should be 91 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapid exchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval shouldbe enclosed in the tender bid. (9) the long term efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals. (10) the documents related to the efficacy and safety of the stent should be only for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent toa major government institute.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45254856 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For srphc82281215-coronary drug eluting stents (1) with single wire design with cobalt alloy shell and platinum iridium core (2) stent with coating of biolinx polymer carrier for active drug zotarolimus shown to be effective in preventing neo-intimal hyperplasia (3) stent diameter should be from 2 mm to 5mm and length of the stent from 8 mm to 38 mm. (4) the strut should be round with thickness ranging from 81 to 91 microns (5) stent delivery system should be monorail (single operator exchange or rapidexchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval should be enclosed in the tender bid. (9) five years efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals.(10) the documents pertaining to the efficacy and safety of the stent should be enclosed for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent to a major government institute. ]

Central Government/Public Sector

CTN :45227572 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For srphc82281210-coronary drug eluting stents (1) single wire technology on cobalt based alloy platform (2) stent with coating of biolinx polymer carrier for active drug zotarolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.25 mm to 4 mm and length of the stent from 12mm to 38 mm. (4) the strut thickness should be 81 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapid exchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval should be enclosed in the tender bid. (9) five years long term efficacy and safety of the stent in terms of target vesselrevascularisation (tvr) and in-situ thrombosis (ist) should be documented / published inpeer reviewed scientific journals.(10) the documents pertaining to the efficacy and safety of the stent should be enclosed for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent to a major government institute.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45227573 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For srphc82281275-des-abbreviated dapt long -coronary drug eluting stents with (1) platinum chromium alloy (2) coating of bioabsorbable polymer carrier for activedrug everolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.5mm to 4mm. the length of the stent should be from 12mm to 48 mm. (4) the strut thickness should be 91 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapid exchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval should be enclosed in the tender bid. (9) the long term efficacy and safety of the stent, the rates of in-stent restenosis (isr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals. (10) safety of abbreviated (three month) dual antiplatelet therapy for high bleeding risk patients should be documented in peer reviewed journals. (11) the manufacturer/supplier should submit proof of supply of the stent to a major government institute. bis standards for the drug eluting stent are not available. (reference:bis catalogue ).[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45227584 Due date: 16 Jun, 202616 Jun, 2026 NA
Tender For srphc82281225-coronary drug eluting stents with (1) cobalt chromium alloy (2) coating of bioabsorbable polymer carrier with abluminal and gradient coating foractive drug shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.5mm to 4mm . the length of the stent should be from 12mm to 38 mm. (4) the strut thickness should be 91 micron or less. (5) stent delivery system should bemonorail (single operator exchange or rapid exchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval should be enclosed in the tender bid. (9) the long term efficacy and safety of the stent, the rates of in-stent restenosis (isr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals. (10) safety of abbreviated (one month) dual antiplatelet therapy for high bleedingrisk patients should be documented in peer reviewed journals. (11) the manufacturer/supplier should submit proof of supply of the stent to a major government institute. bis standards for the drug eluting stent are not available. (reference:bis catalogue ).[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45227585 Due date: 16 Jun, 202616 Jun, 2026 NA
Tender For srphc82281280-des-pt/cr : coronary drug eluting stents (1) on platinum chromium platform (2) stent with coating of polymer carrier for active drug everolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter shouldbe from 2.5mm to 4mm and length of the stent from 12mm to 38 mm. (4) the strutthickness should be 91 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapid exchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved bydcgi . the copy of dcgi approval should be enclosed in the tender bid. (9) the long termefficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals.(10) the documents pertaining to the efficacy and safety of the stent should be enclosed for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent to a major government institute.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45227589 Due date: 17 Jun, 202617 Jun, 2026 NA
Tender For srphc82281246-coronary drug eluting stents with (1) cobalt chromium alloy and with coating of polymer carrier for active drug everolimus. (2) crossing profile less than or equal to 0.0425 inch and mid marker stent placement. (3) stent diameter should be from 2.0 mm to 4 mm and length of the stent from 8 mm to 38 mm. (4) the strut thickness should be 81 micron. (5) stent delivery system should be monorail (single operator exchange or rapid exchange). (6) stent should be compatible with 5fr guidingcatheter (7) stent design should be open cell type. (8) stent should be approved by dcgi.the copy of dcgi approval should be enclosed in the tender bid. (9) the long term efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals.(10) the documents pertaining to the efficacy and safety of the stent should be enclosed in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent to a major government institute.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
 Loading, Please wait...

Connect us via What's Up