Tender For supply of hand held thermal imaging camera completewith 2 year warranty,technical requirement confirming to rdsoletter no.el/7.1.108/sbc/main dtd. 26/11/2024 and having irresolution: 160 x 120 pixels, digital image enhancement:yes,thermal sensitivity/netd:less than 70 mk, field of view (fov):71 degree x 56 degree , minimum focus distance: 0.3 m (0.98 ft),distance to spot ratio: 24:1, image frequency: 8.7 hz,focus:fixed, focal plane array/spectral range: uncooled microbolometer/7.5 to 14 micro mtr., detector pitch: 12 micro mtr,display resolution: 320 x 240 pixels, screen size: 2.4 inchportrait, color palettes: iron , rainbow, white hot, black hot,arctic, lava, image adjustment: automatic, image modes: msx(multi spectral dynamic imaging)visual with temperaturereading, object temperature range: -25 degree c to 380 degree c(-13 degree f to 716 degree f), measurement accuracy: -25degree c to 50 degree c (-13 degree f to 122 degree f): up toplus minus 3 degree c (plus minus 7 degree f) 50 to 100 degreec (122 to 212 degree f): plus minus 1.5 degree c (plus minus 3degree f) or plus minus 1.5% whichever is greater 100 degree cto 380 degree c (212 degree f to 716 degree f): plus minus 2.5degree c (plus minus 6 degree f) or plus minus 2.5% whicheveris greater, ir temperature resolution: 0.1 degree c (0.2 degreef), repeatability of reading: plus minus 1% of reading or plusminus 1 degree c (2 degree f), whichever is greater, responsetime: 150 ms, ir thermometer measurement: continuousscanning, minimum measurement distance: 0.26 m (0.85 ft),type-k range: included type-k probe: up to 260 degree c (500degree f), type-k accuracy: plus minus (1.0% + 3 degree c (7degree f)), spotmeter: center spot on/off, set-up commands:local adaptation of units, language, date, and time formatsscreen brightness (high, medium, low) gallery, deletion ofimages, emissivity correction: yes: 4 preset levels with customadjustment of 0.1?0.99, storage capacity on 4 gb card: 50,000images,image file format: jpeg w/ spot temp data, digitalcamera resolution: 2 mp (1600 x 1200 pixels), adapts to ir lens,flashlight: 100 lumens led, on/off option, class 1 laser: projectscenter spot and outlines circular measurement area to indicatesize, bluetooth: ble, usb: type-c: data transfer, power, batterytype: rechargeable 3.7 v li-ion battery, battery operating time: 5hrs scanning, battery charging time: 4 hrs, to 90%, powermanagement: adjustable: off, 5 min, 15 min, 30 min,shock/vibration: 25 g (iec 60068-2-27); 2 g (iec 60068-2-6),drop: designed for 2 m (6.56 ft), weight: 0.394 kg (13.9 oz),size (l x w x h): 210 x 64 x 81 mm (8.3 x2.5 x 3.2 in) make brand must be : flir-tg-268.269, bosch-gtc-400c, fluke-pti-120, testo &tipl only [ warranty period: 30 months after the date of delivery ] ]
Tender For tender for the supply of various equipments - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles, karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard, refrigerated centrifuge (bench top), bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples., gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25m (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25m),, "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 l recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:, matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water., ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubings, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 l, 20 l, 50 l, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each of, c8 = 250 4.6 5m c18 = 250 4.6 5m, cyano = 250 4.6 5m. amino = 250 4.6 5m, phenyl = 250 4.6 5m. silica = 250 4.6 5m., all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., ft-ir with atr & liquid cell, " hydraulic press with kbr die and pellet holder, suitable mortar pestle (dia 5-6 cm), suitable portable de humidifier to maintain 30- 60% rh, temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab., reference nist standard polystyrene film (0.3 mm) over the range of 3800 cm-1 to 650 cm-1., abbes refractometer,
Tender For supply of mainboard/cpu board+program+factory settings, make: e+h (earlier sick),part no. 2029695, printed-circuit board assemblies description: #main board# printed-circuit board assembly, loaded with current software version and device data according to analyser serial number- 750269, spare part suitable for all s700, sidor analysers, measuring chamber typ4,compl.co h=10/20 detectors, make: e+h (earlier sick),part no. 2037553, description: co detector, suitable for co analyzer tag no. 02-ai179, serial no. 762203, measuring chamber/sensor (thermor) for h2 analyser, make: e+h (earlier sick),part no. 2028444, common h2 detector for analysers tag no. 03-ai264/05-ai-122 & serial nos. 730759/750269, front plate with front film with display & pcb assy,make: e+h (earlier sick),part no. 2037382, co analyser tag no. 02-at-179, suitable for s700 & sidor analyzsers, ir source/emitter lamp including connecting cables for sidor co analyzer, make: e+h (earlier sick), part no. 2037524 (note: 2040471)analyzer tag no.02-at179 and serial no. 762203
Tender For supply , installation & commissioning of provision of aspiration type smoke detector (sampling point) in lavatories in place of hasp in ir coaches to rdso specification no. rdso/2008/cg-04 rev.05 or latest and design no. md22161 dated 18.08.21., one coach set consists of 1) aspirating nozzle - 04 nos, 2) adapter for aspirating nozzle - 04 nos, 3) capillary sampling connectors- 8 nos 4) trunk adapter- 4 nos, 5) safety cover for aspirating nozzle - 04 nos, make- fogpro india [ warranty period: 30 months after the date of delivery ]