Get complete information related to latest Screw Hooks Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Screw Hooks Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Screw Hooks Tenders.
Tender For annual rate contract for supply of electrical goods for street light and other electrical work in visnagar nagarpalika - supplying of double walled corrugated pipes (dwc) of polyethylene (conforming to is 14930 ii )with necessary connecting accessories of same material at required depth in existing trench for laying of cable. below ground / road surface for enclosing cable ((a)50 mm outer dia, supplying of xlpe (is:7098) (i)-88 isi armoured cable multistrand / solid aluminium conductor for 1.1 kv. to be laid on wall with necessary clampsor in existing trench / pipe of following size of cables (c) 4 core 10 sq. mm, supplying of xlpe(is:7098) (i)-88 isi unarmoured aluminium cable 1.1 kv.grade to be erected as directed of following size.(a) 2 core 2.5 sq. mm, supplying of xlpe(is:7098) (i)-88 isi unarmoured aluminium cable 1.1 kv.grade to be erected as directed of following size. (b) 2 core 4 sq. mm, supplying of flexible pvc insulated multi strand multi core 1.1 kv grade isi marked copper wires of following size to be erected as directed. (e) 1.50 sq.mm 3 core round pvc sheathed, supplying of flexible pvc insulated multi strand multi core 1.1 kv grade isi marked copper wires of following size to be erected as directed. (h) 2.50 sq.mm 3 core round pvc sheathed, supplying single phase ccms, supplying three phase ccms, repairing of single phase ccms, repairing of three phase ccms, supplying approved make smc press moulded composite frp. loop-in, loop-out approx. 2mm thick box complete with bakelite connector strip 5way(3pplusnpluse),din rail for mounting mob and hinged doors as per requirement having locking arrangements with mounting clamp with nuts, bolts and washers suitable for erection on pole with cable clampsand earth bolt of following size of box.(b) 250mm x 200mm x 100mm [deep], supplying approved make digital time switch having lithium cell 6 years operative and operate battery backup 1 channel day clock with 14 memory programme, suitable to operate on 240v plus 5., 16a with, floating contacts minimum switching setup time 1 minimum and lcd display. also comprised permanent on/off switching. programming switches and housed in fire proof thermoplastic enclosure and transparent cover erected as required with necessary connection erected as directed., supplying electrical insulation l.t. tape role with isi marked having nominal width 1.8 cms nominal length 8.0 mtr nominal thickness 0.125 mm and having self adhesive pvc, plyer 8" (taparia), tester (taparia), screw driver 12" (taparia), safety gloves 11kv, safety shoes, supplying ac-3 duty 3 pole power contactor with 2 no and 2 nc auxcontacts complete with 415v/220v operating coil suitable for (landt, bch,t.c., siemens, cands make). (a) for 25 / 32 a rating, supplying ac-3 duty 3 pole power contactor with 2 no and 2 nc auxcontacts complete with 415v/220v operating coil suitable for (landt, bch,t.c., siemens, cands make). (c) for 60 / 70 a rating, supplying ac-3 duty 3 pole power contactor with 2 no and 2 nc auxcontacts complete with 415v/220v operating coil suitable for (landt, bch,t.c., siemens, cands make). (e) for 110 a rating, supplying miniature circuit breaker single pole 6a to 25a suitable to operate on 240 v a.c. system and having breaking capacity 10 ka to be erected in existing box. confirming to is 8828/1996 with isi mark cat.iii, supplying 240 v mcb double pole switch for lighting load (b curve) having 10 ka breaking capacity and confirms to is : 8828 in existing box having following capacity (a) 6 to 32 amp.cat.iii, supplying 240 v mcb double pole switch for lighting load (b curve) having 10 ka breaking capacity and confirms to is : 8828 in existing box having following capacity (b) 40 amp. cat.iii, supplying 415v mcb four pole switch for lighting load (b curve) having 10ka breaking capacity and confirms to is :8828 in existing box having following capacity (a) 6 to 32 amp. cat.iii, supplying 415v mcb four pole switch for lighting load (b curve) having 10ka breakin
Tender For supply of earth discharge rod assembly for 25kv ac traction to be supplied along with two rail clamps and cable as per rdso specn.no.eti/ohe/51(9-87) rev-1 (oct-92) with a & c slip no.1 dt.11.03.2022 or latest with (7.5 + 1.5 mtrs). top clamp (10mm to 20mm dia conductor) and cable (size 248 x 0.45mm) as per is 1554 / 1988. total assembly should be supplied in canvas bag. (warranty period: upto 30 months from the date of delivery)
Tender For supply of various type non-centralized material - supply of holding clamp for st pole sp-33 with n&b., supply of holding clamp for st pole sp-55 with n&b., supply of holding clamp for pcc pole with n&b., supply of lt clamp for pcc pole with n&b., supply of stay clamp for pcc pole with n&b., supply of earth wire clamp for pcc pole with n&b., supply of lt clamp for st pole sp-23 with n&b., supply of earth wire clamp for st pole sp-23 with n&b., supply of lt clamp for st pole sp-33 with n&b., supply of suspension clamp with eye hook., supply of earth wire clamp for st pole sp-33 with n&b., supply of dead end clamp with j hook., supply of lt shackle insulator size 75x90 mm with n&b.
Tender For tender for supply of 33kv line maintenance between jaduguda and narwapahar for two years : : - replacement of 33kv pin insulator including supply of necessary fixing materials. this includes binding of acsr dog conductor also , replacement of 33kv disc insulator including supply of necessary fixing materials in existing 33kv line , replacement of 33kv cross arm including supply of necessary fixing materials , replacement of packing pieces in existing cross arms , replacement of pg clamp for dog conductor including supply of necessary fixing materials , installation of complete stay set including supply of necessary fixing materials. this includes digging of stay pits and grouting of stay rod in cement concrete foundation also as required , installation of gi wire 7/10 swg for stay including supply of necessary fixing materials , installation of gi wire 8 swg for guard wire , installation of gi wire 7/14 swg for earth wire including supply of necessary fixing materials , replacement of back clamp for cross arm & top bracket (50mm x 10mm flat) including supply of necessary fixing materials , installation of d.p. channel (100mm x 50mm x 6mm) 1 x 3 mtrs including supply of necessary fixing materials , installation of d.p. channel support clamps including supply of necessary fixing materials , replacement of earth clamps for earth wire including supply of necessary fixing materials , replacement of side stay clamp including supply of necessary fixing materials , replacement of angle stay clamp including supply of necessary fixing materials , replacement of cross bracing for d.p. structure including supply of necessary fixing materials , replacement of clamp for x-bracing including supply of necessary fixing materials , installation of earthing pit using pipe earth electrode as per drawing including connection to earth wires and supply of necessary materials required it , laying & tensioning of acsr dog conductor including fixing / binding at insulators in the 33kv line (per km consist 3 conductor of ryb phases). , tensioning of dog conductor and supporting & fixing on insulators including binding as required in the section (per km consist 3 conductor of ryb phases). , cutting and removal of hages , trimming of trees and branches of size more than 4inch dia and disposal of un-serviceable materials to ucil canteen building as per direction of eic , cutting and clearing jungle grass including uprooting of rank kegetation , long grass , bush wood , trees and saplings upto 4inch dia measured at a height of 1 meter above ground level as per direction of eic , erection of m.s. rail pole 105 lbs , 13 meters long including drilling of 2 nos holes of 5/8inch dia as required at one end of rail pole for fixing of f- clamps , installation of ab switch on double pole structure. this includes fixing of required channels and clamps and other fixing as required and for proper operation. this includes connection of dog conductor alsodog conductor also , installation of 33kv lighting arrestor on double pole completed with line and earth connections , maintenance of ab switch on double pole structure , 33kv line patrolling from narwapahar to jaduguda , replacement of earth spike along the 33kv line & connection to pole , number of rail pole with painting of pole upto 6 feet height for colour coding of line
Tender For bid to ras supply of electrical items c c - ml for flame proof point wiring with two single core frls h pvc insulated pvc unsheathed multi stranded copper conductor cable of size 1 point 5 sqmm 1100v , supply install testing of flame proof metallic body exhaust fan single phase 230v 50hz 300mm 1440 rpm with louvers and shutter including civil work , ml switch flame proof rotory type with termination box in lm 6 16 a single phase 250v complete all as specified and directed by engr in charge , supply and fixing db spn 4 way db including all fixing accessories complete all as specified and directed by engr in charge , supply and fixing mcb sp 6 to 32 amps 240v rupturing capacity 10 ka c series complete all as specified , supply and fixing mcb db 20 amps 240v breking capacity 10 ka complete all as specified , ml for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick surrounded with charcoal and salt buried directly in ground , ml for submain wiring with 2 single core pvc insulated unsheathed multi stranded copper conductor frls wire 4 sqmm 1100v grade incl one 4 sq mm pvc insulated , supply lay jointing testing xlpe insulated lt under ground cable 1100v grade heavy duty armoured with multi stranded aluminium conductor laid in trenches ducts , excavation in trenches n exc 1 point 5m wide and n exc 1 point 5m in depth for foundation etc or for shafts wells cesspits manholes pier holes laying of cables etc , ml for tibba sand cushioning to under ground cable in trenches existing cable trenches ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying , ml for 40 to 50 mm thick rough dressed jodhpur type stone slab 25 to 35 cm in width of 80 cm long laid dry abutting each other for protection to under ground cable , ml for removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1 point 5m above the ) /bid number : gem/2025/b/6562017 * /dated: 20-08-2025 & & / bid document 1 / 20 & & ' ' /item category starting point complete , ml for returning, filling in including spreading leveling watering and well ramming in layers not exc 25 cm complete all as specified and as directed , ml for gi tubes in replacement of 32mm bore size light grade galvanised including fittings with clamp of 25x3 flat iron welded to pipe fixed to wall , supply install testing or commissioning of inverter tech split wall mounted ac indoor outdoor unit with cordless remote control cap 1 point 5 tr make lg blue star hitachi voltas lyod , supply fixing heavy duty copper pipe 12mm 1 oblique 2 inch dia bore thickness 0 point 70 mm complete incl brazing welding nuts bolts and screws , supply fixing heavy duty copper pipe 6mm 1 oblique 4 inch dia bore thickness 0 point 70 mm complete inclu brazing welding nuts bolts and screws , supply and fixing new nityrile rubber insulation for copper pipes suitable for split ac of capacity from 1 point 5 to 2 tr complete all as directed by engg in charge , supply fixing in replacement wall mounted digital voltage stabilizer for automatic operation single phase naturally air cooled indoor type designed for input variation between 150 to 285v , sf sheet metal enclosure 2 pin earth plug socket complete with one single pole mcb of 20 amp capacity complete all as specified and directed by engr in charge , sf wiring from indoor to outdoor unit size 2 point 50sqmm pvc insulated multistranded frls 4 core round cable incl fixing of thimbles for split type air conditioner 1 point 5 to 2 tr , m l for surface sub main wiring with two runs of 4sqmm single core pvc insulated unsheathed multistranded with copper conductor cable 1100v frls h grade isi marked , supply fixing new pvc drain pipe 15 mm dia with coupler joint for split or window ac complete all as specified as directed , supply fixing in replacement outdoor unit odu stand for 1 point 5 or 2 tr type split ac complete all as specified as directed
Tender For supply of re glanding works , cable fault identification , cable rectification , supply of copper jumpers , construction of earth pit , earth pit revamping , copper earthing rod , cea liasoning charges , insulation mat testing , analog voltmeter and ammeters , breakdown visit of ups , thermography of panels , cable laying and termination , calibratin of lux meter , calibration of multimeter , calibration of clamp meter , calibration of earth tester , calibration of megger , calibration of ir thermometer , calibration of insulation continuity tester , transformer oil filtration and testing , transformer oil supply and filling , transformer insulation resistance checking