Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s
Tender For procurement of led lamp and accessories 5 items-holders lamp and accessories holder lamp heavy duty for inspection hand-lamp with rubberised handle wire guard heat resistance glass b.c.holder suitable for use upto 100 watt pin type bulbs acceptable make: comet led bulb with e27 screw cap watts: not less than 27 watts input voltage 220-240v ac light output:3000 lumens colour day cool colour temperature:5500-6500k colour rendering index: >/-80 beam angle:120 deg (wide beam angle) acceptable make: philips/hpl/crompton/osram/havells/syska/surya/wipro/orbit warranty: one year minimum dimension diameter less than 135mm total height less than 200mm led bulb with e27 screw cap watts:40+/-10% input voltage 220-240v ac light output:4000 lumens colour cool day light colour temperature:6000-6500k colour rendering index: >/-80 beam angle:120 deg acceptable make: philips/hpl/crompton/osram/surya warranty one year minimum dimension diameter less than 130mm total height less than 205mm led flood light fitting voltage: 170-250 v ac watts: 120-130 w ip rating: not less than ip 65, acceptable make: any indian make warranty: minimum 2 years led flood light fitting watts: 150 type ref: bvp176 150 spd, code:bvp176 led 165 cw 150w fg gr psu. acceptable make: philips
Tender For corrigendum : providing of light inspection vehicle as required of recent and latest make model on hire charges basis for official use of executive engineer for inspection works under tanker services
Tender For supply of portable emergency lighting equipment box (peleb) complete with all accessories and confor ming to rdso's specification no. rdso/pe/spec/tl/0012-2000 (rev.'0') june 2000, amendment no.1. the li st of accessories are as below : - (i)portable emergency lighting equipment box drg. no.skel-2356 alt.6. (ii ) telescopic tri pod stands rg.no. skel-2395 alt.1. (iii) flood light assembly complete with two lamps drg,n o.rdso/pe/sk/tl/0010-2000 (rev. 2). (iv) inspection lamps and its holder complete drg. no.-4271 alt.3. (v) crocodile clip drg.no. skel-2695 [ warranty period: 30 months after the date of delivery ]
Tender For providing of light inspection vehicle (scorpio/bolero/innova on monthly basis for official use of superintending engineer jal shakti hydraulic circle doda.
Tender For providing of light inspection vehicle such as mahindra scorpio or bolero (not older than 2020 model) on monthly rent/hire charges basis for a period w.e.f 01/05/2025 to 30-04-2026 for official use of executive engineer, flood control division jammu
Tender For supply of battery operated motor trolley for track inspection 6 passenger sea ting capacity +1 driver seat lakshmi brand or similar battery operated light weight motor trolley powered by 48 volts 60 ah li-ion battery having carry capacity of 6 persons-3 on fr ont seat and 3 on back bench with sun shade brakes, front & back lights, horn, charger, in sulated, maximum speed 20 kmph complete with tool kit. [ warranty period: 30 months after the date of delivery ]
Tender For providing of light inspection vehicle (scorpio/bolero/innova with valid commercial permit) of the model not before than january 2023 on hire charges basis excluding pol for an average run of 2000 km per month (mileage exceeding 2000 km shall be paid