Tender For supply of in situ spectroscopic measurements - spectrometer , wide band light source , software , sample chamber , lasers for excitation , accessories , absorbance, photoluminescence and hyperspectral xy autoscan system , ozone chamber , source measuring unit for burn-in test for two channels , system integration of transient measurements , custom filter wheels as per the sizes , sample holders , halogen bulb
Tender For providing and supplying various rquired material for gp shivade financial year 2025/2026 for gp shivade - school requird material led tv, computer and printer, bachtgat material-chakki, gp office sound system, anganwadi requird material-fan tube light etc, bake (bakade)purchase, furniture purchase-table ,chair,cupboard fan etc
Tender For estimation purpose for supply, installation, testing and commissioning of gps system to light duty & heavy duty machinery under the office of executive engineer, mechanical store division, dapodi, pune
Tender For tender for supply of imecticide chlorpyriphos 10% gp to prevent insects from entering the signalling equipment. , supply of 2w/4w light weight portable control telephone to specification no. irs: tc: 78-2000 with latest amendment. , tape pvc adhesive for insulation purpose size (20mmx10mtrs) in a roll make-steel grip, pidite, or similor , supply optical power meter with visual fault locator as per specification make vaim/exfo/fluke/tempo , cat6 u/utp cable for indoor use 305 mtrs. make d-k securenet, digisol , supply of single fiber media converter optical to ethernet 1350/1550 optical & 10/100/1000 mpbs ethernet of make , mrotek/rad/cygnus/digisol/dolinic , sc to lc ofc patch cords 10 mtr long , wired computer mouse or trackballs make dell, hp, lenevo , single pair pvc drop wire of 0.91 mm.dia cadmium copper conductor , 12 v/10 amp battery charger for 25 watt vhf set as per specification copy attached , sport network switch make d-link, tp-link, tenda , supply of 24 ports un managed non poe layer 2 access , switch make tp-link, d-link, cisco , "supply of hdmi cable of 20 mtr. (high speed ultra hd), make honeywell/cable orsation/bluerigger/zebronic supply of two way counter communication system with attendant init, customer uit, power supply unit and dedicated cable for connecting the system"" ", "supply of wall & surface mount speaker, 100watt rms maka jbl begringer, blue plunk or similar supply of ofc single made de fiber unarmored cable, ", make: molex/amp/finolex/dink/policab , supply of single mode full duplex auto sensed fiber media converter as per specification, warranty 2 year , supply of lan extender with 4 port ethernet with 230v ac/48v dc working with ac power cord, as per specification no. rdsq/spn/tc/82/2020 rev. 2.0 or latest.
Tender For supply of polycarbonate seal - 1- seals should be made of high quality of uv stabilized polycarbonate plastic materials (engineering plastic), which shall give complete visualization of its fixing mechanism and shall show clear indication if tampered and it should not be effected by boiling water etc- the seal must be able to withstand harsh environment direct sunlight exposure.the seal will be tamper evident with double locking system with additional third locking system facility, which works when the double anchor system is put in place with the female part of the seal. the seal should be transparent clear. the seal should be of one- piece polycarbonate body consisting of capsule and double locking anchor having stainless steel twisted wire (two stained) of 20 cm long molded itself in the temper proof seal male part. the wire should be non-corrosive and nonmagnetic made of 304 grades. sequential serial nos. of one alpha and six numeric numbers to be provided on the female part. the seal should have high rise molded logo be embossed of purchaser and companys name one each side of the seal. the provision for tamperproof sticker signature in the field of13.5mm x 21.5mm should be given, as and when the purchaser requires the need for the same for its proper utilization. the sealing arrangement should be such that its original position cannot be restored after any effort of tamper or breaking of the seals. the third lock as said should work as deterrent for opening the main male & female part of the seal.packaging: the seal should be supplied in packet of 100 seals. each packet shall be labeled for following information., 1.1- the seal should have following essential features.a. tamper resistanceb. heat resistance c. environmentally safed. should withstand direct sun light & rain water exposuree. tamper evident: material must show clear sign of tampering when material is compromised by penetration, drilling cutting, bending or pulling etc.f. one end of the wire should be loose and other end of wire should be permanently fixed on the upper part of female body passing thru the male part of sealg. ultra violet ray resistant h. must have third lock to secure male & female part from tampering.the sealing mechanism should be such that it can be sealed without using any pliers or tools. the sealing procedure must be fool proof and there should not any scope of pre tampering/malpractice with sealing wire while sealing.above mentioned essential features of seal must be verified by approved laboratory test report including melting point test, boiling water test, temperature with stand test etc.construction: one piece construction comprising of polycarbonate capsule & anchor and integrally connected pin part lock & non corrosive & nonmagnetic 2 strand twisted stainless steel sealing wire, all these features molded into one piece {called seal}capsule: contains and internal locking mechanism which accepts the anchor and permanently secure the sealing wire.anchor: the locking cap shall have double anchors, which secures the loose end of the sealing wire into the capsule locking mechanism.pin lock: lt is molded in the seal at time of manufacturing of the said seal and passes. through female part and locks the male part and secures the seal at the operational level
Tender For providing new lighting system with 12.5 mtr high mast, new poles, under ground cables, and led street light fittings, and e.i. work with led fittings in cover shed 75x200 at main auction platform in pc ghrachon m.c. bhawanigarh district sangrur.
Tender For corrigendum : repair/replacement and maintenance of lt cables, dg set, street light, e/m fire fighting system including connected items at af stn baknaur, kalpi and rajpura under ge (af) ambala
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s