Get complete information related to latest Security Light Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Security Light Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Security Light Tenders.
Tender For corrigendum : repair/maintenance of main distribution boards, service connections, submain wiring, building securitylights, building earthing and connected works under ge (east) mathura
Tender For repairs maintenance of electrical and mechanical equipments high mast light search lights and other miscellaneous items at cad pulgaon - disconnecting and taking down existing unserviceable street lights/flood lights any type/watts from pole/wall and dismantling the light fittings. repairing/replacing unserviceable parts re-fixing the same on pole/wall after testing and removal of carbon from line jumpers/tightening of jumper/alignment of fitting defective street light/securitylight/flood lights fitting/led light from electric pole complete all as directed by eic. note: spare parts and accessories such as led driver, and connected items etc will be measured and paid separately under respective item as supply only and fixing is deemed to be included in this item., supply only led street light driver for 45 watts led street light as per make given all as specified and directed by eic., supply only led street light driver for 60 watts led street light/ flood light type as per make given all as specified and directed by eic., supply only led street light driver for 100 watts led street light/ flood light type as per make given all as specified and directed by eic., supply and fix in repair led streetlight of 45 watt comprises of pressure die cast aluminium housing & having system efficiency>123 lumens/watt i.e 5570 lumens,all leds should be highpower leds of 1w to 3w only with modular lens for batwing shape distribution of 30 degree & 60 degree,input voltage working range is 140 vac to 270 vac,brand name should be embossed,potted driver is used with 4kv internal & external 5kv potted surge protection,short circuit protection,open circuit protection,high & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,ip66 protected,thd10%,cri>70 cct 5700+/-300k,pf>0.9,driver efficiency>85%,lm79 report required from nabl accredited lab. including taking down old unserviceable fittings and bracket house must be adjustable or if required any cost of all fixing hardware shall be included in quoted rate complete all as specified and directed by eic note : 1. engraving of ca number on each lighting fitting (street light / flood light) shall be carried out by the contractor and the cost of the same shall be deemed to be included in the quoted rate. 2. no extra payment shall be made on this account. 3.the complete fitting along with led module, driver, surge protection device and all associated accessories shall be covered under 05 (five) years comprehensive warranty by the contractor from the date of invoice.make : philips/ wipro/crompton, supply and fix in repair led streetlight of 60 watt comprises of pressure die cast aluminium housing & having system efficiency>110 lumens/watt i.e 6670 lumens,all leds should be highpower leds of 1w to 3w only with modular lens for batwing shape distribution of 30 degree & 60 degree,input voltage working range is 140 vac to 270 vac,brand name should be embossed,potted driver is used with 4kv internal & external 5kv potted surge protection,short circuit protection,open circuit protection,high & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,ip66 protected,thd10%,cri>70 cct 5700+/-300k, pf>0.9, driver efficiency>85%,lm79 report required from nabl accredited lab. including taking down old unserviceable fittings and bracket house must be adjustable or if required any cost of all fixing hardware shall be included in quoted rate complete all as specified and directed by eic. note : 1. engraving of ca number on each lighting fitting (street light / flood light) shall be carried out by the contractor and the cost of the same shall be deemed to be included in the quoted rate. 2. no extra payment shall be made on this account.3. the complete fitting along with led module, driver, surge protection device and all as
Tender For corrigendum : provn of securitylights and connected places at certain locations and special repair to lt feeder panel along with associated works at af stn issapur construction of 25 wg under ge (af) gurgaon
Tender For corrigendum : ca no. ge af no.1 / gur-49 / 2026-27 repair/maintenance of street lights, perimeter securitylights, high mast lights, solar lights and incl allied works at x area and repair/maint of internal point wiring fittings/ fixtures, ceiling fan 54 asp
Tender For repair to drains, compound wall, repair and desilting, cleaning/ replacement of float valve oh tanks, repair and maint of internal wiring, ceiling fan, securitylight along with allied wks in sila grn under age reasi of ge nagrota
Tender For repair/replacement of unsv light fitting of any type with smart led fitting, earthing, meter boxes, db s, building securitylight and other connected items under ge (n) santacruz, mumbai
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/securitylight, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs securitylights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be