Tender For providing of custom bid for services - supply and installation of industry 4.0 module for machines of hcc section of o.f. katni: implementation of digital monitoring of process & production with smart control and solution, predictive maintenance & energy monitoring system (ems) with intelligent features & capture real time data regarding overall equipment performance..
Tender For fire work at esic haryana. - (a) supplying, installation, testing and commissioning of electric driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required :(b) horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520.(c) suitable hp squirrel cage induction motor, tefc, synchronous speed 1500 rpm, suitable for operation on 415 volts, 3 phase 50 hz, ac supply with ip 55 protection for enclosure, horizontal foot mounted typewith class-f insulation, conforming to is-325.(d) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) suitable cement concrete foundation duly plasteredwith anti vibration pads., 2280 lpm at 70 m head, (a) supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required:(diesel driven pump)(b) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520.(c) suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulatedwith 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event offault with audio indications, painted with post office red colour etc. as required.(d) m.s fabricated, common base plate, coupling, couplingguard, foundation bolts etc. as required.(e)suitable cement concrete foundation duly plasteredand with anti vibration pads., 2280 lpm at 70 m head, (a) supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (jockey pump)(b)horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is : 1520.(c) suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase 50 hz ac supply with ip 55 class of protection for enclosure, horizontal foot mounted type with class-f insulation, conforming to is : 325.(d) m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) suitable cement concrete foundation duly plastered and with anti vibration pads., 180 lpm @70m head, fabrication, supply, insallation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :, incomings630a, 50ka 4 pole mccb, ics=100% icu rating digital voltmeter 0-500v with selector switch ammeter (0-630 a) with selector swtich & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps set of copper bus bar 800amps outgoings (note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump200 amp, 50ka tpn mccb, ics=100% icu, with f
Tender For corrigendum : re processing and interpretation of legacy 2d and 3d seismicdata and 3d broadband seismic api for bengal basin - re-processing & interpretation (p&i) of legacy 2d & 3d seismicdata and 3d broadband seismicdataacquisition, processing & interpretation (api), bengal basin
Tender For corrigendum : re processing and interpretation of legacy 2d and 3d seismicdata and 3d broadband seismic api for mahanadi basin - re-processing & interpretation (p&i) of legacy 2d & 3d seismicdata and 3d broadband seismicdataacquisition, processing & interpretation (api), mahanadi basin
Tender For corrigendum : re processing and interpretation of legacy 2d and 3d seismicdata and 3d broadband seismic api for cauvery basin - re-processing & interpretation (p&i) of legacy 2d & 3d seismicdata and 3d broadband seismicdataacquisition, processing & interpretation (api), cauvery basin
Tender For corrigendum : re processing and interpretation of legacy 2d and 3d seismicdata and 3d broadband seismic api for kg basin - re-processing & interpretation (p&i) of legacy 2d & 3d seismicdata and 3d broadband seismicdataacquisition, processing & interpretation (api), krishna godavari basin
Tender For corrigendum : hiring of services for 3d broadband seismicdataacquisition and processing in oalp viii and ix blocks of western offshore, india
Tender For e-tender for procurement of some consumable items for two years from the date of award of contract (aoc)- disposable surgeons full wrap around gown specification: the products should be eo sterilized & ready to use, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 18g - length-15cm/10cm/8cm/ 6cm/4cm) with seldinger technique, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 22g - length-15cm/10cm/8cm/6cm/4cm) with seldinger technique, blood pressure equipment, sphygmomanometer, digital with pulse recording and 100 reading memory, blood transfusion set, sterile, disposable • medical grade non toxic and dehp free tubing with 200 micron filter • clear, transparent, flexible molded drip chambers with fix fluid filters and bacteria retention air vent transparent spike for easy piercing • efficient roller control for better flow control • molded “bulb type” injection site for extra medication • approximately 20 drops, l ml dw • sterilization by eto or more advance process. leur lock., bipap mask with bronchoscopy port along with accessories detachable & autoclavable vented / non vented swivel connector., blood cardioplegia device - adult - heat exchanger pleatal type. priming volume of heat exchanger : <30 ml . integrated heat exchanger with bubble trap. assemble with class vi implant tested tubing. high cooling eficiency. eassy set up and priming. outlet comnnection 1/4" built in bridge for choice of 100 % blood and 100 % cardiopledgia solution delivery., blower mister kit : comfortable hand grip with a 6.5" (16.5 cm) malleable stainless steel shaft for ease of positioning near the surgical site.the soft; silicon tip contains a plastic tube which carries saline to the tip ., burret set (100ml), c-arm cover 2 part materials-plastic, sterile pack, ready to use., catheter mount, collapseble catheter mount with bronchoscopy and suction port, cervical spinal locking plate assorted size with required screw, material – titanium, close suction with non returnable valve and terbojet clining system. sizes 10,12,14 fr., connector - straight assorted sizes - pvc material, sterile pack, coronary shunts assorted size : bevelled ultra-soft tip , obstruction -free flow path , large atraumatic sealing surface & flexible shaft., cvc3 fr. with anti kinking nitinol guide wire (paediatric)- 6cm/l0cm/15 cm with long shelf life >5 years. thermosensitive polyurethane double lumen paediatric cvc with accessories., cvp transducer : integrated unit for clinical accuracy. dual mode of flushing controlled squeeze and snap-tab. completely transparent for easy priming and debubbling with flushing of 3 cc / hr or without flush. easy zeroing. standard closed loop sampling kit / double. [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], cvp transducer compatible with arterial pulse contour monitor (disposable single use) [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], disposable sterile full gown with eye protection sterile disposable prepackaged, disposable ventilator circuit with single water trap. should be tidel volume range from 200 ml to 1500 ml. should be minimal deade space 55 ml. medical grade pe. connector 15/22 mm m/f for y piece, connector 15/22 mm m/f for ett & mask. standard length . 6ft. or expandable length., dome kit with flushing system. • should be single line monitoring dome. • should be measure invasive pressure., digital foetal doppler, eye drape • sheet size: 80 x 75 cm - 90 x 75 cm • adhesive area: 9 x 7 cm with 6 eye lid holders • drainage pouch of transparent pe film • eto (eo) sterile, face mask , disposable ,should be manufactured from non woven poly prop fabric ,should be 3 ply construction,should have high bacterial filtration efficiency ,should be cor ners, length of string should be 40 cmheat sealed to keep 3 layers together ,standard size 17.5 x 9 cm, colour green / blue ,th
Tender For procurement of some consumable items - disposable surgeons full wrap around gown specification: the products should be eo sterilized & ready to use, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 18g - length-15cm/10cm/8cm/ 6cm/4cm) with seldinger technique, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 22g - length-15cm/10cm/8cm/6cm/4cm) with seldinger technique, blood pressure equipment, sphygmomanometer, digital with pulse recording and 100 reading memory, blood transfusion set, sterile, disposable medical grade non toxic and dehp free tubing with 200 micron filter clear, transparent, flexible molded drip chambers with fix fluid filters and bacteria retention air vent transparent spike for easy piercing efficient roller control for better flow control molded bulb type injection site for extra medication approximately 20 drops, l ml dw sterilization by eto or more advance process. leur lock., bipap mask with bronchoscopy port along with accessories detachable & autoclavable vented / non vented swivel connector., blood cardioplegia device - adult - heat exchanger pleatal type. priming volume of heat exchanger : <30 ml . integrated heat exchanger with bubble trap. assemble with class vi implant tested tubing. high cooling eficiency. eassy set up and priming. outlet comnnection 1/4" built in bridge for choice of 100 % blood and 100 % cardiopledgia solution delivery., blower mister kit : comfortable hand grip with a 6.5" (16.5 cm) malleable stainless steel shaft for ease of positioning near the surgical site.the soft; silicon tip contains a plastic tube which carries saline to the tip ., burret set (100ml), c-arm cover 2 part materials-plastic, sterile pack, ready to use., catheter mount, collapseble catheter mount with bronchoscopy and suction port, cervical spinal locking plate assorted size with required screw, material titanium, close suction with non returnable valve and terbojet clining system. sizes 10,12,14 fr., connector - straight assorted sizes - pvc material, sterile pack, coronary shunts assorted size : bevelled ultra-soft tip , obstruction -free flow path , large atraumatic sealing surface & flexible shaft., cvc3 fr. with anti kinking nitinol guide wire (paediatric)- 6cm/l0cm/15 cm with long shelf life >5 years. thermosensitive polyurethane double lumen paediatric cvc with accessories., cvp transducer : integrated unit for clinical accuracy. dual mode of flushing controlled squeeze and snap-tab. completely transparent for easy priming and debubbling with flushing of 3 cc / hr or without flush. easy zeroing. standard closed loop sampling kit / double. [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], cvp transducer compatible with arterial pulse contour monitor (disposable single use) [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], disposable sterile full gown with eye protection sterile disposable prepackaged, disposable ventilator circuit with single water trap. should be tidel volume range from 200 ml to 1500 ml. should be minimal deade space 55 ml. medical grade pe. connector 15/22 mm m/f for y piece, connector 15/22 mm m/f for ett & mask. standard length . 6ft. or expandable length., dome kit with flushing system. should be single line monitoring dome. should be measure invasive pressure., digital foetal doppler, eye drape sheet size: 80 x 75 cm - 90 x 75 cm adhesive area: 9 x 7 cm with 6 eye lid holders drainage pouch of transparent pe film eto (eo) sterile, face mask , disposable ,should be manufactured from non woven poly prop fabric ,should be 3 ply construction,should have high bacterial filtration efficiency ,should be cor ners, length of string should be 40 cmheat sealed to keep 3 layers together ,standard size 17.5 x 9 cm, colour green / blue ,there should be a string each at all four, flexible annuloplasty ring - assorted sizes, complete
Tender For e-tender for procurement of some consumable items for two years from the date of award of contract (aoc)- disposable surgeons full wrap around gown specification: the products should be eo sterilized & ready to use, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 18g - length-15cm/10cm/8cm/ 6cm/4cm) with seldinger technique, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 22g - length-15cm/10cm/8cm/6cm/4cm) with seldinger technique, blood pressure equipment, sphygmomanometer, digital with pulse recording and 100 reading memory, blood transfusion set, sterile, disposable • medical grade non toxic and dehp free tubing with 200 micron filter • clear, transparent, flexible molded drip chambers with fix fluid filters and bacteria retention air vent transparent spike for easy piercing • efficient roller control for better flow control • molded “bulb type” injection site for extra medication • approximately 20 drops, l ml dw • sterilization by eto or more advance process. leur lock., bipap mask with bronchoscopy port along with accessories detachable & autoclavable vented / non vented swivel connector., blood cardioplegia device - adult - heat exchanger pleatal type. priming volume of heat exchanger : <30 ml . integrated heat exchanger with bubble trap. assemble with class vi implant tested tubing. high cooling eficiency. eassy set up and priming. outlet comnnection 1/4" built in bridge for choice of 100 % blood and 100 % cardiopledgia solution delivery., blower mister kit : comfortable hand grip with a 6.5" (16.5 cm) malleable stainless steel shaft for ease of positioning near the surgical site.the soft; silicon tip contains a plastic tube which carries saline to the tip ., burret set (100ml), c-arm cover 2 part materials-plastic, sterile pack, ready to use., catheter mount, collapseble catheter mount with bronchoscopy and suction port, cervical spinal locking plate assorted size with required screw, material – titanium, close suction with non returnable valve and terbojet clining system. sizes 10,12,14 fr., connector - straight assorted sizes - pvc material, sterile pack, coronary shunts assorted size : bevelled ultra-soft tip , obstruction -free flow path , large atraumatic sealing surface & flexible shaft., cvc3 fr. with anti kinking nitinol guide wire (paediatric)- 6cm/l0cm/15 cm with long shelf life >5 years. thermosensitive polyurethane double lumen paediatric cvc with accessories., cvp transducer : integrated unit for clinical accuracy. dual mode of flushing controlled squeeze and snap-tab. completely transparent for easy priming and debubbling with flushing of 3 cc / hr or without flush. easy zeroing. standard closed loop sampling kit / double. [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], cvp transducer compatible with arterial pulse contour monitor (disposable single use) [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], disposable sterile full gown with eye protection sterile disposable prepackaged, disposable ventilator circuit with single water trap. should be tidel volume range from 200 ml to 1500 ml. should be minimal deade space 55 ml. medical grade pe. connector 15/22 mm m/f for y piece, connector 15/22 mm m/f for ett & mask. standard length . 6ft. or expandable length., dome kit with flushing system. • should be single line monitoring dome. • should be measure invasive pressure., digital foetal doppler, eye drape • sheet size: 80 x 75 cm - 90 x 75 cm • adhesive area: 9 x 7 cm with 6 eye lid holders • drainage pouch of transparent pe film • eto (eo) sterile, face mask , disposable ,should be manufactured from non woven poly prop fabric ,should be 3 ply construction,should have high bacterial filtration efficiency ,should be cor ners, length of string should be 40 cmheat sealed to keep 3 layers together ,standard size 17.5 x 9 cm, colour green / blue ,th