Web Analytics Made Easy - StatCounter

Selective Level Meter Scrap Tenders

Get complete information related to latest Selective Level Meter Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Selective Level Meter Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Selective Level Meter Scrap Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40044754 Due date: 23 Apr, 202523 Apr, 2025 NA
Tender For request proposal for supplying various equipment, chemicals, standard reference microbial cultures, glasswares/ plasticwares and general items in 13 numbers of district level water testing laboratories of jharkhand a-ranchi zone - refrigerator- ( 265 litre approx., double door ),make & model: branded ( is standard), analytical balance-( 4digit), weighing capacity of 220g, externally calibrated by nabl accredited lab/agency with calibration certificate, make & model: branded) ( is standard), ph meter-(measuring range ph0.0-14.0), make & model: branded ( is standard), hot plate with magnetic stirrer-(power: 2000 watt approx., operating volts: 230 15 volts a/c), stirring capacity : 50-1500 rpm, plate size : 1 ft *1.5ft (approx), make & model: branded ( is standard), bacteriological incubator-digital construction -double walled construction outer body made of mild steel powder coated & inner body made of stainless steel, insulation : glass woll insulation between two walls. inner size : 18" x 18" x 24", rating watts 750, no. of shelves 3, capacity 120 ltrs, temp range- 5 c - 60 c accuracy +/- 0.5 c, temp controlled by : controlled by pid micro process controller with dual display. selves : with g.i. wire mesh selves, door : 2 door inner acrylic door to view sample & outer metal door with air circulation motor with blower for uniform temperature throughout chamber. heater : special nichrome heater designed for long life & saving of power consuption. thermometer type : electronic with digital display. make & model : branded ( is standard), laminar air flow chamber(biosafety cabinet)-external dimensions (lxwxh) in inches and mm:40 x34.25 x56.7, (1020 x870x 1440) work area dimensions: 34.45 x24 x22.52 (857x610x572) material of construction: galvanised iron sheet with epoxy polyester thermosetting powder coating of 80 microns, 1.5mm thickness/stainless steel grade 304,1.2mm for ss modelsbody finish: glossy off white colour for gi powder coated table top: 1.2mm ss 304 sheet of matt finish pressed on 25mm solid nuwud board side glass: 6mm float glass encased in stainless steel channels front door: frameless gas spring loaded swinging type polycarbonate 6mm thickness wheels and levelling lugs: pu solid wheels with plated brackets and metallic powder coated design: front bottom loading pre-filters or completer work area with stainless steel including hepa grill cleanliness class: iso standard 14644-1- class 5 stages of filtration: a.pre-filters= 10 with an efficiency of 90 % washable hdpe media in frp pu coated frame b.mini pleat hepa filter encased aluminium frame with an efficiency of 99.995% motor blower assembly: variable speed mtor mounted on pu coated frp blowers with aluminium powder coated impellers velocity: 100 fpm at 6 from face of the filter noise level: less than 60db at 1 meter from the face of the equipmenthepa filter grill: stainless steel grills duly perforated and polished electrical specifications: a. switches and speed controller: microprocessor controlled feather touch switch panel b. fluorescent lighting: 18 watt. c. chokes for lighting: 18 watt d. ultraviolet lighting: 1.5 feet length g15t8, 15 watt power consumption: 250 watts lighting: greater than 800 lux power supply: 230v,50hz power supply, single phase 5 amperes power cord accessories: gas burner, gas/vacuum cock ( is standard), autoclave -vertical autoclave size 14" dia x 22" ht, rating in watts 3000, capacity of 52 ltrs complete s.s with foot lifting arrangement used for sterilization under saturated steam pressure at 15psi with double walled units with inner chamber made of thick stainless steel and outer chamber made of s.s.lid is made of thick gauge stainless steel with pressure gauge steam release valve, and safety valves. with foot lifting arrangement. with s.s. basketaccessories:1. digital temperature indicator cum controller with timer -1 no.2. water level cut off-1no.3. pressure cut off switch-1no. ( is standard), digit

State Government

CTN :39984717 Due date: 18 Apr, 202518 Apr, 2025 NA
Tender For supply of following items for setting up measurement and instrumentation lab for 4 year b.tech in electrical engineering curriculum and application for university of calcutta. - experimental set-up for calibration of a wattmeter using dc potentiometer with following features/items:regulated power supply 2 volts, 100 ma to operate the potentiometer.calibrated electronic standard cell voltage 1.0186 volts.regulated power supply 0-5 volts/0.5 amps with milliammeter 0- 500ma for current coil of wattmeter.regulated high voltage power supply 0-250 dc volts with voltmeter 0-250 volts for pressure coil of wattmeter.a panel mounting wattmeter 0-125 watt is required to perform the experimentgalvanometer for null balance.a volt ratio box for measurement of higher voltage.complete circuit diagram with wattmeter connections to be provided on the front panel of the instrument.with standard accessories, experimental set-up for low resistance measurement using kelvin s double bridge with following features:range: 0.2 micro ohm to 11 ohms, with an accuracy of 0.05 %required accessories:spot reflecting galvanometer. dc source 10 a with one analog current meter. attachment of 1 meter length.brass clamp with terminals for zero setting. with standard accessories, experimental set up for unknown capacitance measurement using de-sauty s bridge with following specifications:source: sine wave signal of 1khz. the amplitude of ac switch indicating lamp is provided on the bakelite board. two sockets are to be provided for the output of ac signals.detector: for detecting small ac signals in the output, null detector is required as in-built with digital display.circuit diagram:the circuit layout on the board is to be provided out to facilitate convenient working. 4 or 5 mm socket required for making connection. features:r2 --- three decade resistance dials having value 10 1000, 10 100 and 10 10 ohmsr1 ---- single decade resistance dial having value 10 100 ohmsc1 ---- unknown capacitor.c2 ---- two fixed standard capacitors having value 0.01mfd 0.1mfd (loss free)with standard accessories, experimental set-up for calibration of a 1-phase watt-hour meter with following scopes: to adjust & calibrate a single-phase energy meter by direct loading method to adjust & calibrate a single-phase energy meter by comparing with a sub-standard meterspecifications: static energy meter single phase: under test (local) duly mounted, wired and terminated static energy meter single phase: sub-standard meter (isi mark) duly mounted, wired and terminated voltmeter: moving iron ac portable of class 1.0 accuracy and range 0 - 300 v ac ammeter: moving iron ac portable of class 1.0 accuracy and range 0 - 10 a ac wattmeter: dynamometer type ac single phase, multi-range with current coil 5 / 10 amp and potential coil 75 / 150 / 300 v ac variac: variable voltage transformer (portable table / floor mounting type with enclosure) input: 230v ac and output: 0 270v / 8 amp ac variable load: made up of 3 load resistors of 70 ohms / 700 w each duly mounted and connected / terminated to form different loads (35 to 210 ohms) as per external connections digital stop clock: portable with start / stop & reset operation set of necessary 4 mm spring loaded patch cords for interconnections detailed instruction manual supply to be connected: 230v, 1phase, 50 hz, ac mains, experimental set-up for calibration of a 3-phase watt hour meter with following specifications: to adjust & calibrate a three-phase energy meter by direct loading method to adjust & calibrate a three-phase energy meter by comparing with a sub-standard meterspecifications:static energy meter three phase: under test (local) duly mounted, wired and terminatedstatic energy meter three phase: sub-standard meter (isi mark) duly mounted, wired and terminatedvoltmeter: moving iron ac portable of class 1.0 accuracy and range 0 - 300 v acammeter: moving iron ac portable of class 1.0 accuracy and range 0 - 10 a acwattmeter:
 Loading, Please wait...

Connect us via What's Up