Get complete information related to latest Semicircular Post Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Semicircular Post Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Semicircular Post Tenders.
Tender For auction sale of 3-ph poly carbonate meter,metal part with porcelain (insulator),scrap empty oil barrel (serviceable)(66 kv vansda s/s),scrap 220 kv class bushing 220 kv popda ss,gi scrap- trolley, gate door,ms scrap 11 kv capacitor bank,silicon rubber insulator,gi earth wire,gi scrap iso base (66 kv valod s/s),63 kva 11kv/415 v station transformer,lead material for battery cell,metal part with porcelin,22 kv feeder panel,66 kv sri,ms scrap (rail pole piece, angle, breaker box etc),11 kv vcb panel ms scrap,battery set (66 kv pandesara b),gi tower material (66 kv talangpore-bhimrad line),22 kv ct,gi tower material,acsr zebra,scrap acsr dog conductor,control cable scrap (copper) (up to 1.1kv)- small pieces,scrap ms girder and gi hardware,earth wire,ms h frame
Tender For tender for supply of spare parts - power contactor 16a at 415v ac coil 24v dc model3tf32 00 0bb4 power contactor biasing damper 24vdc siemens , siemens 3rh1921 1ba01 auxiliary contact block make siemens model 3rh19211ba01 type front top mounted auxiliary contact block contacts 1 no normally open electrical ratings pilot dutyac a600 600 v ac 10 a continuous dc q600 300 v , siemens 3rh19211ca01 auxiliary contact block make siemens model 3rh19211ca01type front top mounted auxiliary contact block contacts 1 nc electrical ratings pilot duty ac , siemens 3tf30 100a power contactor aa11 make siemens model 3tf30 100a type power contactor poles 3 main poles rated operational current ac3 9 a at 415 v ac auxiliary contacts 1 no integrated coil voltage 110 v ac 50 60 hz rated insulation voltage ui 690 v utilization category ac3 ac4 mounting din rail or screw mounting standards iec 6094741 is iec60947 4 kw at 400 v ac power contactor silo , 3ua52 002a thermal overload relay make siemens model 3ua52 002a type thermal overload relay current range 10 16 a trip class 10a reset mode manual automatic auxiliary contact 1 no 1 nc rated insulation voltage ui 690 v mounting direct mount to siemens 3tf30 31 contactors or separate base protection of motors against overload phase failure and unbalanced load standards iec 6094741 thermal overload relay swas , siemens 3th30 220a auxiliary contactor relay make siemens model 3th30 220a type auxiliary contactor relay contacts 4 2no 2nc rated operational current ie 10 a ac15 4 a at 230 v 2 a at 400 v rated insulation voltage ui 690 v coil voltage 110 v ac 50 60 hz standard compliance iec 6094751 mounting din rail or panel mounting , semiconductor fuse rating 10a size 000 make siemens , semiconductor fuse rating 2a size 000 make siemens , semiconductor fuse rating 4a size 000 make siemens , semiconductor fuse rating 6a size 000 make siemens , auxiliary contactor coil dc with 2no 2nc contacts model 3th30 22 0bb4 siemens , motor protection with overload relay function mpcb biasing damper 24vdc motor protection circuit breaker size s00 with overload relay model 3rv2111 1da10 overload release setting 22 32 a short circuit release 42 a size s00 function motor protection w overload relay connection type screw terminal screw terminal suitable motor 400v 11 kw biasing damper 24vdc , type 3 pole contactor model 3ts30 100a make siemens specifications type 3 pole contactor coil voltage 230v ac power rating at 415v 4 kw approx auxiliary contact 1 no rating ac1 25 a ac3 9 a utilization category standard ac3 duty motor application up to 4 kw 415v 3 phase3 power contactor higher rating mcb swas make siemens , type 3 pole power contactor make siemens series sirius model 3rt2015 2ab01 coil voltage 24v ac 5060 hz utilization category ac1 18 a ac3 7 a rated voltage up to 690 v motor rating ac3 1point 5 kw 230v 3 kw 400v 4 kw 690v auxiliary contact 1 no 1314 built in terminals main 1l1 3l2 5l3 2t1 4t2 6t3 coil a1 a2 mounting din rail panel standard iecen 60947 41 power contactor silo , motor starter protector mpcb silo motor protection circuit breaker size s00 model 3rv2011 1aa10 standard mpcb size s00 trip function thermal magnetic main application simple motor switching protection connection type screw terminal screw terminal number of poles 3 adjustment range current 1point 1 to 1point 6 a instantaneous release magnetic 21 a trip class 10 operational voltage 20 to 690 v ac insulation voltage 690 v ac surge voltage resistance 6 kv mains frequency 5060 hz mpcb silo , type 3 pole contactor model 3ts30 100a make siemens specifications type 3 pole contactor coil voltage 230v ac power rating at 415v 4 kw approx auxiliary contact 1 no rating ac1 25 a ac3 9 a utilization category standard ac3 duty motor application up to 4 kw 415v 3 phase3 power contactor higher rating swas make siemens , thermal overload relay model 3us50 001k8k current range 8 12point 5 a tolr swas co ordination type 2 25a type 3na make siemens , add on auxialiry c
Tender For corrigendum : supply of xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , capacitors for electric fan motors as per is 1709 (v2) (q3) , elecric bells and accessories as per is 2268 (q3) , self ballasted led lamps (led bulb) (v3) conforming to is 16102 (part 2) (under bis scheme - ii) (q2) , miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1) (q2) , miniature circuit breaker boards for voltages conforming to is 13032 (q3) , non modular piano type domestic fan regulator conforming to is 11037 (q3) , non modular piano type domestic electrical sockets isi marked to is 1293 (q2) , modular piano type domestic electrical switches isi marked to is 3854 (q2) , non modular piano type domestic electrical switches isi marked to is 3854 (q2) , cable of size 2 core 0.75 sqmm twisted 90mtr roll , casing caping pvc 20mm , dol starter 1000 watt , holder angle insulated , inverter based led bulb 12 watt , inverter based led bulb 9 watt , led tubelight 18 watt , led tubelight 20 watt , power contactor 3 pole 110 amp , power contactor 3 mn x 25 , socket outlet 6 amp modular , solar street light 30 watt lumen led output 120 lumen per watt , solar street light 45 watt lumen led output 175 lumen per watt , starter for 7point5 hp submersible pump , switch socket combination 16 amps , switch socket combination 6 amps , switch socket combination 6oblique16 amps , tape insulation pvc , timer switch light sensor type nature switches three phase * /bid number : gem/2026/b/7552142 + /dated: 06-06-2026 ' ' / bid document 1 / 42
Tender For supply of residual circuit breaker with overload (rcbo) 4 pole, 16 amps, 415 v ac, d-curve, breaking capacity 10ka, sensitivity 30ma, impulse current withstand at 8/20 stands for microsecond pulses3 ka ,make- part no. a9n4p16d + a9v61440 of m/s schneider or equivalent of m/s abb, m/s legrand, m/s lk, m/s siemens [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of ht and lt breaker spares - sc210290424 mccb, model-dm16, rating -1.6a,40 deg c ui 690v, 50 or 60hz, icu-65ka, ics-75 percent icu, instantan- 19a, is 13947-2 iec 60947-2, utilisation category-a, with limit switch landt or equi , sc210290427 mccb, dn2- 160h3,63a landt or equivalent , sc210170054 mccb,make- landt model dm100,rating-25a 40 deg c,ui- 690v,50 or 60hz,icu -65ka,ics-75 percent,instantan-300a,is 13947-2 or iec 60947-2,utilisation category-a,with limit switch landt or equi , sc210290425 mccb,model-dm16,rating - 7.5a 40 deg c, ui 690v, 50 or 60hz, icu-65ka,ics-75 percent, instan- 90a,is 13947-2 or iec 60947-2,utilisation category -a,with limit switch landt or equi , sc210290426 mccb,model- dm16,rating -5 a,40 deg c ui 690v, 50 or 60hz, icu- 65ka,ics-75 percent icu, instan-60a,is 13947-2 or iec 60947-2,utilisation category, with limit switch landt or equi , sc210170088 mccb,model-dm160,rating -160 a,40xc ui 690v,50 or 60hz, icu-65ka, ics-75percent icu,instan-1920 a,is 13947-2 or iec 60947-2,utilisation category -a,with limit switch landt or equi , sc210290429 mccb ,model- dm100,rating -80 a,40xc ui 690v,50 or 60hz,icu-65ka,ics- 75percentage icu,instan-960 a,is 13947-2 or iec 60947- 2,utilisation category -a,with limit switch landt or equivalent , sc210290428 mccb , model-dn3-400m, rating -400a, ui 415 or 440v, 50 or 60 hz, u 8kv, icu - 50ka, ics 100percent icu, cat - a,is or iec 60947-4,with limit switch landtor equi , sc050130075 power contactor, 3 pole, type no mnx 80, rating 80a, coil voltage 110v ac for chp,with add on block make-landt , sc050130064 u power spring charging motor, 240v ac for chp, make - landt , sc050130084 contactor,3 pole, type no mnx 140,rating 140a, coil voltage 110v ac for chp,with add on block make - landt , sc050130056 contactor, 3 pole, type no mnx 50, coil voltage 110v ac for chp,with add on block make - landt , sc050150366 power contactor mnx265, with add on block,265 a 415 v 3 pole 2no plus 2nc make - landt , sc050150365 power contactor mnx110, 230 ac coil supply,110a,415v, with add on block, 2no plus 2nc make - landt , sc050150367 power contactor, 3 pole, type no mnx 50, with add on block, coil voltage 230v ac for chp. make - landt , sc050150358 contactor,mno 40e, coil voltage 110,4no 4nc make - landt , sc050150359 contactor, mno 31e,coil voltage 110 v ac make - landt , sc050150360 contactor,mno 22e, coil voltage 24v dc make - landt , sc050150364 contactor,mxo 22e,coil voltage 110vdc, ac-15, ue 415v - ie4a,ui 690v, lth-10a make - landt , sc050150363 contactor,mxo 22e, 220vdc, with add on block make - landt , sc050150362 contactor,mx0 40e, 220vdc, with add on block make - landt , sc050150361 contactor,mx0 31e, 220vdc,with add on block make - landt , sc210290423 mpcb, 415v, rotary type, thermal magnetic, 1-1.6 a, mog-h1-0401, make - landt or equivalent , sc210290419 rcbo,415v, 32a,4 pole,100ma make - landt or equivalent , sc210290420 rcbo,415v, 32a,2 pole, 32ma make - landt or equivalent , sc210290422 rcbo,415v, 32a,4 pole,32ma make - landt or equivalent , sc210290421 rcbo, 415v, 32a,2 pole, 100ma make - landt or equivalent
Tender For supply of supply and installation of online ups systems including batteries , supplyand installation and commissioning of 4 pole 40 amps mcb breaker , supply and installation of 4c x 6 sqmm copper cable , supply and installation of 6 way surface pvc box of switches , supply and installation of 1c x 2.5sqmm copper wire from online ups for 14 computers power points , labour charges for laying cable wires conduits mcb breakers power points with writing for online ups system and computers
Tender For corrigendum : supply of online ups system : : - supply and installation of online ups systems including batteries , supplyand installation and commissioning of 4 pole 40 amps mcb breaker , supply and installation of 4c x 6 sqmm copper cable , supply and installation of 6 way surface pvc box of switches , supply and installation of 1c x 2.5sqmm copper wire from online ups for 14 computers power points , labour charges for laying cable wires conduits mcb breakers power points with writing for online ups system and computers