Web Analytics Made Easy - StatCounter

Sensing Device Tenders

Get complete information related to latest Sensing Device Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Sensing Device Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Sensing Device Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :42432995 Due date: 12 Nov, 202512 Nov, 2025 NA
Tender For supply of load sensing device

Central Government/Public Sector

CTN :42433754 Due date: 09 Dec, 202509 Dec, 2025 NA
Tender For supply of load sensing device

Central Government And Public Sector

CTN :42025548 Due date: 31 Oct, 202531 Oct, 2025 NA
Tender For corrigendum : supply of load sensing device v t a valve , distributor valve complete , brake cyl. complete os12gh21, pt. no. 601

Central Government/Public Sector

CTN :39772442 Due date: 24 Oct, 202524 Oct, 2025 NA
Tender For bid to ras corrigendum : supply of belt longitudinal rupture sensing device

Central Government/Public Sector

CTN :42297567 Due date: 27 Oct, 202527 Oct, 2025 NA
Tender For supply of load sensing device for container flat wagon

Central Government/Public Sector

CTN :42322478 Due date: 10 Nov, 202510 Nov, 2025 NA
Tender For supply of pressure sensing device

Central Government/Public Sector

CTN :42244915 Due date: 18 Nov, 202518 Nov, 2025 NA
Tender For supply of hose pipe assembly for load sensing device item no. 1,2,6 and 7.

Central Government/Public Sector

CTN :42242007 Due date: 27 Oct, 202527 Oct, 2025 NA
Tender For supply of load sensing device.

State Government

CTN :41676459 Due date: 17 Oct, 202517 Oct, 2025 NA
Tender For corrigendum : empanelment of agencies for supply of different laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoride & nitratemeter: ph/ion/ mv-redox-orp/ temperature benchtop meter with electrode for testing both fluoride & nitrate separately in water samples. technical specification: ph range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 accuracy 0.002 ph + 1 lsd calibration points up to 5 buffer sets: usa/ nist/ din/ custom orp range 2000.0 mv rel. mv range 2000.0 mv accuracy 0.2 mv resolution 0.1 mv ion concentration 0.001 to 19999 ppm resolution up to 3 digits relative accuracy 0.5 % full scale (monovalent) and 1 % full scale (divalent) calibration points up to 8 temperature range 0 to 100 c, 32 to 212 f resolution 0.1 accuracy 0.3 c/ 0.5 f compensation: auromatic temperature correction other requirement: auto buffer recognition, memory 500 with time and date stamp rs 232 alarm for calibration due & out of range alurm auto logging function., fluoride electrode of ion metersame make that of the ion meter, nitrate electrode of ion metersame make that of the ion meter, manifold filtration assembly (to be used for micobiological test)* sturdy and easy to clean ss filtration assembly with funnel, manifold unit, air vent filter and vaccum pump ready to be used for mictobiological testing * specification: # funnel with inbuilt clamp: made of ss 316, capacity: 300 ml, ss filter support base, ss support screan: 47 mm, made of ss 316l; filtration area 9.6 cm2; silicon stopper: size 8, with silicon lid and silicon o ring. # filtration manifold: 3 place manifold, made of ss 316, valves made of ptee, connection 12 mm; suitable for both pp and ss funnel with rubber stopper fittings. # vacuum pump: oil free, piston powered, suitable to be used with 3 possition manifold; max flow rate: 34 l/ min; vaccum stage: double. max vaccum: 100 mbar. the vaccum pump should also have a vacuum suction bottle to protect the pumps componennt by preventing liquid or solid material from entering the pump during filtration process., voltage stabilizer (3 phase)# capacity- 3 kva # input voltage range: 295 v - 465 v normal range # output voltage range 380 v / 400 v / 415 v # output regulation: 1 %; # output settability: 380 v - 420 v; # frequency: 47 hz - 53 hz; correction rate: 70 v/ sec; # aircooled servo stabilizer, three phase., heating mantle (single station) should have safety cut off with precise heating for boiling, evaporation, distillation or extraction process technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 350 degree celcius. accuracy: 1.0 degree celcius, display: led display with temperature, time; construction material: ms; power consumption : 150 w, semi automatic digestor for cod analysis with all assssories material of construction epoxy painted with chemical resistant coating; temperature range ambient to 450 deg c # stability of temperature 0.5 deg c # temperature calibration - automatic; selectable ramp: upto 4 per program; digestion time range: 1 to 999 minutes; time selection: 1 minutes steps; countdown: digital readout; heating places - 6 possition; size of tubes: 250 ml test tubes (42 mm); power 1000 w; number of programmable methods 20 numbers. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint., digital thermometer with probe# mini lcd thermometer # type: digital, # sensor cable length: 1 meter water proof probe # batteries: 2 x batteries should be included, # temperature range: - 50 - 110 oc, # temperature measurement accuracy: 1 0c, micropippete stand#self-standing holder accommodates most major brands of pipettes. #material: pmma, # capacity: 5 pipptes/stand, conical flask draining rack#material: acrylonitrile-butadiene-styrene/polycarbonate, # no. of pegs: 20

Central Government/Public Sector

CTN :42106341 Due date: 12 Nov, 202512 Nov, 2025 NA
Tender For supply of load sensing device for container flat wagon
 Loading, Please wait...

Connect us via What's Up