Get complete information related to latest Separator Filter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Separator Filter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Separator Filter Tenders.
Tender For supply of electric slaughterhouse (for animals) - primary & secondary chamber primary chamber* single chmber furnace of size 4270 mm x 1980 mm x 1820 mm.* plate thickness- 5 to 8 mm.* lining of interior of furnace- 400 mm wall cermaic blanketk, high aluminia refractory brick is-8-1994 line with insulation brick is 2042-2006* operation temperature- 800o c to 1000o c.* top smoke discharge for secondary chamber.* ash removal doors to be provided for ash collection after combustion.* ingtion- automatic.* temperature control- automatic* material loading- front gate- automaticsecondary chamber* operating temperature - 1050o c to 1250o c.* material of construction- mild steel with high aluminia refractory brick is-8-1994 line with insulation brick is 2042-2006.* made from is 2062 grade mild steel materials (or better) duty lined with insulation bricks, refractory bricks, hysil boards.* burner mounting arrangement with refractory burner block.furnace door:furnace door charging & discharging side fabricated from 5mm to 6 mm thickness door opening & closing automatic.ash door:* ash door (with casted cement lining) to remove nonhazardous ash from the chamber.* top inlet bottom smoke discharge for longer gas residence time.* furnace door charging & discharging side fabricated from 5mm to 6 mm thickness.* door opening & closing automatic/manual.refractory:{complete set of refractory shaped bricks for construction electric cremation of i.s. 8 bricks (approx. 1007nos bricks,insulation 4000 nos. refractory slid for construction of flue duct , as required, refractory heat resistant fire clay , ceramic blanket hysil board, asbestos ropes etc. as required for outer side of the furnace shall be constructed by red bricks by sand and cement as mortars and construction of chimney from basement of roof level including painting i.e. bricks portion shall be painted by two coats of red oxide as primer and to coats of synthetic enamel. (a) complete lining & assembling of entire cremation chamber according to standard size with proper arrangement of accommodation of heating elements, resting of dead body with sufficient opening for falling of ashes to the ash chamber & sufficient ventilation for fresh air spraying. (b) complete lining and assembling of entire cremation chamber according to standard size with provision of drawing out aces from the rear side and sufficient ventilation for fresh air injection. complete lining and assembling of entire cremation chamber according to the standard size with provision of air inlet supplying by fresh air blower and arrangement of multi ventilation path for fresh air}. osspl make, thermocouple heat sensor supply & fixing the thermocouple of heat sensing range 0 - 1200 c (cr.-al) sensor housed in s.s 304 casing of dimension 1200 mm long 22 mm od complete encased to and fitted terminal on other and for connection of compensating of 2 cores 0.5 aq. mm cr- al for heat sensing from thermocouple to temperature controller covered with asbestos embedded rope about 50 m length as per direction of eic., f.d. fan/centrifugal air blower with electric motor * supply and delivery at site, installation, testing and commissioing.* of fresh air injection system forced draft fan mild steel.* type: centrifugal.* capacity:- 500 cmh.* pressure:- 220 mmwg.* motor rating:- 2hp (kirloskar/crompton), burner assembly * total 2 nos. of lpg/cng/png fired automatic burner required.* the burner should be provided with comprising diffuser plate/ burner plate, photo cell housing electrodes with holding brackets, solenoid valve, electrodes caps, flexible hose pipes, spary nozzles, oil filter, blower, etc. connected with electric motor (each burner) & in built air regulator.* burners will work on auto on/off as per the set temperature for the combustion chambers.* the in-built bolwer will provide continuous air flow to the burners to prevent demages due to high temperature., supply and fixing of manifold with a p
Tender For supply of various lab equipments items for govt. pg college guna district guna (m.p.) - supply of various lab equipments items for govt. p g college guna district guna (m.p.), waterand soil testing analysis kit (digital) : range ph 0 to 14.00 resolution ph 0.01 accuracy ph 0.01 1 digit temp. comp. 0 to 100 deg. c., water bath (06holes) : 6 hole8 ltrs., waterbath(12holes) :12 hole 20 ltrs., water distillation apparatus(single distillation unit 2 litre/hour) : single distillation 5 litres, analytical balance : least cosunt 0.0002g, analytical weight box : 1-100g, fractional weight box : 1-500mg, physical balance : 250gm accuracy 0.1g, digital balance : least count 1mg, single pandigital balance : 0.1mg 200g, digital photoelectric colorimeter : 8 filter,1 ml, digital potentiometer : with hot plate and electrodes, digital conductometer : with cell 1cc and 0.1cc, d.o. meter : polarographic do range: typically 0 to 90 mg/l (milligrams per liter) or 0 to 600% saturation.rdo (optical) do range: usually 0 to 50 mg/l or 0 to 500% saturation., digital naphelo/turbidity meter : digital turbidity cum nephelometer range:-, 200,1000 ntu/jtu resolution:- 0.01 ntu/jtu accuracy:- 3% fs, 1digit display:- 3 digit 7-segment led light source:- ir led detector:- photodiode sample system:- 60 x 25mm clear glass test tubes power:- 230 v 10% ac, 50 hz accessories:- test tube set of 2, operation manual, dust cover, polarimeter half shade : the specific rotation ( ) is a physical property defined as the optical rotation at a path length of 1 dm, a concentration of 10 g/l, a temperature (usually 20 c), and a light wavelength (usually sodium d line at 589.3 nm), melting point apparatus :melting-point measurement range: room temperature - 400 c setting rate of the starting temp. : 50 c~400 c 5 min; 400 c~50 c 7 min minimum digital display: 0.1 c size of the capillary: 1.4mm (outside diameter) 1.0mm (inside diameter), 90mm equipped with color camera and color monitor to observe melting point with ease validation program for standard samples 8 operator names can be storedgraphic lcd display to display all test parameters & test instructions, digital melting point apparatus :melting point measurement range : ambient to 300 deg c starting melting point temperature : settable from 50 to 300 deg c heating time : 3 minutes (up to 300deg c) cooling time : 5 minutes (from 300 deg c) accuracy : +/ 0.5 deg up to 200 +/ 0.8 deg from 200 to 300 temperature display resolution : 0.1 deg c rate of heating (deg c per minute), abbe refractometer : safety bs en 60950-1:11/2006 emc en 55024 : 10/2003 en 55020 : 11/2005, tlc kit : outstanding standardization and quality control exceptional adherence, hardness and surface homogeneity. analyzing samples with high matrix- load without sample preparation. multiple samples analyzed in parallel.highly cost-efficient, fast and economical, centrifuge : 6000rpm, corkboring machine :adjustable guide that permits holes to be bored in any part of a stopper, the knurled chuck - 9/16" (14mm) shank of the eight, plated-steel borers included with the unit. the steel borers range from 3/16" to 5/8" (4.8mm to 15.9mm) in 1/16" (1.6mm) increments,, distillation apparatus : single distillation 5 litres, oven hot air : 14" 14" 14 , voltage stabilizer : 2kv, vertex shaker : 6 tube capacity, mixer small : moter capacity 900 watt, water bath(cu) : 4 , heating mantle with energy regulator : 500 w,2litre, single crucible heater : helical wire coil moldatherm insulation platinel ii thermocouple with 10tm compensated lead wire and polarized plug ceramic fiber hearthplate programmable heat-up to setpoint temperature indicates setpoint and process temperatures temperature: 1200 c (2192 f) maximum crucible sizes: 5 (top vestibule id) x 8 (heated depth), water bath rectangularsingle walled : 6 hole 8 ltrs., water bath rectangular :2 hole, kjeldahl distillation unit : unit of 3 tests, microwave oven : 30 ltr convection compatible, soleextractionunit apparat
Tender For procurement of spares of bharat panther cft ba no. 24p037349l - air dryer cartridges , grease ngli ii , engine oil filter , engine fuel filter , filter fuel , air filter element , filter ad blue , screen for ad blue , steering filter element , filter fuel water separator , filter element air cleaner for cleaner m80064
Tender For supply of engine oil filter , engine fuel filter , filter fuel , air filter element , air filter element for air compressor , steering filter element , p165659, spin-on assy, filter oil , filter- water fuel separatorfilter cartridge prefilter
Tender For supply of ceramic filter, pn aic.b.11001 , o ring gasket for probe,pnaic.b.11002 , spring and stand for filter,aic.b.11003 , solenoid valve two way,pn aic.b.11005 , diaphragm pump, pn aic.b.11008 , diaphragm pump,pn aic.b.11010 , drain pump,pn aic.b.11028 , electrical type gas cooler, aic.b.11032
Tender For supply of procurement of ahp instrument air dryer e e - 2 way valve high temperature , 2 way valve low temperature , 4 way valve spare kit , nrv 15nb , nrv 50nb , pre filter element , after filter element , safety valve , activated alumina , ceramic ball , moisture seprator assembly , cooler o ring kit , ball valve
Tender For supply of lead acid stationary secondary cell 200 ah low maintenance in dry and uncharged condition with intercell connectors, nuts and bolts, one micro porous vent cum sealed float guide having dome / filter made of ceramic or any other suitable fire retardant material confirming to irs: s:88/2004 or latest with 2v nominal voltage in hard rubber or ppcp container. shelf life 4 years.
Tender For supply of lead acid stationery cells, 80 ah, low maintenance in dry & uncharged condition with inter-cell connectors, nuts, bolts one micro porous vent cum sealed float guide having dome/filter made ceramic or any other suitable fire retardant material, conforming to spec. no. irs-s-88/2004, str: siq 0113 ver. 1.0 with 2v nominal voltage in hard rubber container.