Get complete information related to latest Service Valve Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Service Valve Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Service Valve Tenders.
Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor
Tender For corrigendum : supply of oh of main steam line valve v2 6 , oh of steam by pass valve v2 27,15, and v2 7 , oh of es 3,4,5,6 and 7 , oh of v2 -82-84 and v2-81-a to 81c , oh of hd-21, hd-29, hd-30 and hd-31 , oh of nrv of h.p. heater and feed pump , oh of group protection valve of hph , oh of dw-4, 37,38,39,40,41 and ca 5 , oh of cst makeup valve v6 60 , oh of as-48 valve , oh of nrv of extraction line es-8 , oh of suction valve of bfp , oh condensate wtr throw off valve to condenser , oh throw off valve to cond and steam isolating of lph2 , oh of steam isolating valve of lph 3, 4 , oh of safety valve of aux prds or deaerator , oh of safety valve of h.p. heater , oh of safety valve of l.p. heater. , oh of safety valve of cbd tank. , oh of safety valve of flange or stud heatng , oh of safety valve of warm up line. , overhauling of actutator of as 48 valve , oh of actr feed line valvev2 81 or v2 82 or v2 83 or v2 84 , oh of actr of v2 7 or v2 15 or v2 27 , oh of actr drip line valve and ext line valve , oh of actr valve connected to condenser , oh of actr cst make valve , oh of actr of msv l and r , oh of actr of steam isolating valve to lph2 to 4 , oh of actr steam throw off valve to condenser , cut or weld or repl of hp valve 15 to 50mm , cut or weld or repl of hp valve 51 to 100mm , cut or weld or repl of h p valve 101 to 150mm , oh of butterfly valve of condenser , oh of dea and fst with internal painting , repair or replacement of broken hanger , tightening of loose hangers , cut or weld or repl of l.p. valve 15 to 50mm , cut or weld or repl of l.p. valve 51 to 100mm , cut or weld or joint of h.p. pipe 15 to 50mm , cut or weld or joint of h.p. pipe 51 to 100mm , cut or weld or joint of h.p. pipe 101 to 150mm , cut or weld or joint of h.p. pipe 151 to 300mm , lift or straight aprds hdr by cutting weldding , o h of lph 1a , 1b , o h of lph 2 3 and 4 , oh and attend flange leakage of gc i or ii , clean of turbine oil or h2 gas cooler str , repl of damaged sp. valve v2 38 , repl of damaged special valve v2 27 , oh of turbine oil coolers , oh of main ejectors of turbine , oh of h.p. heater , oh of lcv 3to15pcv-5, 14,16,17,tcv 8 , repl bend of lp drip connected to drip pump or condenser , cut damaged bend of hph drip cont to dea , cut weld or repl of h.p. valve 151 to 300mm , blank of crh line for ht and normalizing , oh of h.p. valve nrv in h.p. line , oh of l.p. valve nrv , oh of energy absorber of bfp , oh of dss of aux. prds.
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded servicevalves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r
Tender For corrigendum : supply of oh of main steam line valve v2 6 , oh of steam by pass valve v2 27,15, and v2 7 , oh of es 3,4,5,6 and 7 , oh of v2 -82-84 and v2-81-a to 81c , oh of hd-21, hd-29, hd-30 and hd-31 , oh of nrv of h.p. heater and feed pump , oh of group protection valve of hph , oh of dw-4, 37,38,39,40,41 and ca 5 , oh of cst makeup valve v6 60 , oh of as-48 valve , oh of nrv of extraction line es-8 , oh of suction valve of bfp , oh condensate wtr throw off valve to condenser , oh throw off valve to cond and steam isolating of lph2 , oh of steam isolating valve of lph 3, 4 , oh of safety valve of aux prds or deaerator , oh of safety valve of h.p. heater , oh of safety valve of l.p. heater. , oh of safety valve of cbd tank. , oh of safety valve of flange or stud heatng , oh of safety valve of warm up line. , overhauling of actutator of as 48 valve , oh of actr feed line valvev2 81 or v2 82 or v2 83 or v2 84 , oh of actr of v2 7 or v2 15 or v2 27 , oh of actr drip line valve and ext line valve , oh of actr valve connected to condenser , oh of actr cst make valve , oh of actr of msv l and r , oh of actr of steam isolating valve to lph2 to 4 , oh of actr steam throw off valve to condenser , cut or weld or repl of hp valve 15 to 50mm , cut or weld or repl of hp valve 51 to 100mm , cut or weld or repl of h p valve 101 to 150mm , oh of butterfly valve of condenser , oh of dea and fst with internal painting , repair or replacement of broken hanger , tightening of loose hangers , cut or weld or repl of l.p. valve 15 to 50mm , cut or weld or repl of l.p. valve 51 to 100mm , cut or weld or joint of h.p. pipe 15 to 50mm , cut or weld or joint of h.p. pipe 51 to 100mm , cut or weld or joint of h.p. pipe 101 to 150mm , cut or weld or joint of h.p. pipe 151 to 300mm , lift or straight aprds hdr by cutting weldding , o h of lph 1a , 1b , o h of lph 2 3 and 4 , oh and attend flange leakage of gc i or ii , clean of turbine oil or h2 gas cooler str , repl of damaged sp. valve v2 38 , repl of damaged special valve v2 27 , oh of turbine oil coolers , oh of main ejectors of turbine , oh of h.p. heater , oh of lcv 3to15pcv-5, 14,16,17,tcv 8 , repl bend of lp drip connected to drip pump or condenser , cut damaged bend of hph drip cont to dea , cut weld or repl of h.p. valve 151 to 300mm , blank of crh line for ht and normalizing , oh of h.p. valve nrv in h.p. line , oh of l.p. valve nrv , oh of energy absorber of bfp , oh of dss of aux. prds. , 2coat paint bcw,clr,bfp,cep,drip pump and line , 2coat paint cst,bcw pump ,swc tank,line,valve , 2coat paint hcplg,sw,bcw,cw exc clr line , 2coat paint air washer sys,cep or phos orhyd , 2coat spray paint syn super enamel lpc , 2coat spray paint front ped,barring gear , 2coat spray paint brg and housing turbine , 2coat spray paint cntl valve casing , 2coat spray paint condenser and line , 2coat spray paint main oil tank , 2coat spray paint main ejector , 2coat spray paint centrifuging machine , 2coat spray paint lube oil cooler , letter writing 2 inch size dia
Tender For mechanical maintenance of equipments in converter shop, hmdp, lp bay,scrap yard and slag yard in sms-2- preventive maintenance of oxygen lance system in sms #2, preventive maintenance of tilt drive system charging and taping doors of converter in sms #2, preventive maintenance of slag cut off dev in sms #2, preventive maintenance of relining car and allied lining equipment, periodic inspection and testing of oxygen lance mechanism of converter in sms #2, periodic inspection of converter tilt drive sms#2 and attending minor points, preventive maintenance of hmdp equipment, preventive maintenance of equipment in aro rinsing station in converter shop of sms #2, preventive maintenance of slag pot transfi car in sms #2, preventive maintenance of scrap box trans car in sms 2, , preventive maintenance of ladle tilter, replacement of lance body, repair of lance body, shifting jam cutting, patch pipe welding and other minor repairs of lance assemblies in sms 2., replacement of oxygen/water hose of lance, replacement of carriage gear box, rope drum pulleys etc in lance drive mechanism slag cut off device of sms #2., repair and replacement of slag skirt segments in converters of sms #2, repair and replacement of radial heat shields on drive side and non drive side of converter in sms #2, repair and replacement brick retainer plates, tap hole dummy flanges providing anchors etc in converters of sms#2, repair of bottom rinsing system pipes tuers, hoses supporting structure etc in converters of sms #2, replacement of converter shell tap hole barrel shells of scrap chutes, ladle shells etc in sms #2, repair of slag pots in sms #2 by welding, replacement of gear boxes up to 350 kg weight in bulk material charging system of sms, replacement of gear boxes of 351 kg to 850 kg weight in bulk material charging system of sms #2, replacement of damaged parts and alignment of fluid coupling co 62a/co 67 a/co65a conveyors, replacement of pulley assemblies of sizes up to 500 mm in belt conveyors in sms #2, replacement of pulley assemblies of sizes 600 mm and above in belt conveyors in sms #2, repair of chutes replacement of steel chute liners etc in conveyor system, replacement of rubber or poly profane liners, replacement of pneumatic cylinders of clam shell gates.gas flaps.compensators and diversion gates etc of bulk material charging system of sms 2, replacement of damaged chutes (other than conveyor chutes) of bulk material and ferro alloy charging system of sms #2, replacement of assemblies like, pneumatically operated diversion gate/gas flap gas lock valve etc ein bulk material charging system of sms#2", replacement of gear boxes in sptchmdp car in sms #2, replacement of wheel assembly in sptc/hmdp car of sms #2, replacement of gear boxes in stc/platform car/hot metal ladle transfer cars of sms #2, replacement of wheel assemblies in stc-platform car hot metal ladle transfer cars of sms #2, replacement of rails in converter section of sms#2, repair of steel teeming ladle hot metal ladle in sms #2 before relining, carrying out miscellaneous mechanical maintennace jobs of type lin converter section of sms #2, carrying out miscellaneous mechanical maintennace jobs of type z in converter section of sms #2, carrying out miscellaneous mechanikal maintennace jobs of type 3 in converter section of sms #2, perkidic inspection of equipments in converter shop, isbh, slag yard, scrap yard and lp bay in sms#2, repair and replacement of technological structures in converter section of sms #2, requir and replacement of auto coupler fixing bracket in steel terming ladles, carrying out steam parging in ladle driers/heaters of sms 2
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - repairs on the valves of all pans installed in the mill (comprising five units: four 40-tonne and one 60-tonne); conduct hydraulic testing by inserting blanks into the calandria as required to identify and replace leaking tubes, repeating the process until no leaks remain; subsequently, fit all manholes, sight glasses, valves (including cut-over and discharge valves), and servicevalves associated with molasses tanks, condensers, and nozzles; complete all necessary repairs and mechanical work; and finally, fill the vessel with water to conduct a satisfactory water trial