Get complete information related to latest Sheaths Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Sheaths Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Sheaths Tenders.
Tender For supply of embryo transfer sheath - 9991267, 1000.000, imv make embryo transfer sanitary sheathref. 006458sanitary sheaths are used to protect the sheath during insemination and prevent contact between the ei sheath and the cow.
Tender For corrigendum : supply of supply of minimum 8 core rack mountable server 32 gb ddr5 ram and 64 bit os 1 tb ssd with required licences for db and application , supply of industrial standard kiosk for mounting the android tablet and flatbed scanner , supply of industrial standard wi-fi enabled android or ios tablet with 4 gb ddr4 ram and 64 gb storage with 10 or more-inch touch panel with ports like hdmi and usb , supply of flatbed scanner to scan the qr code in the boarding pass or air ticket , supply web or mobile application software for the verification of passenger details in the terminal area with integratable api of the airlines , manageable poe switch 24 port , 9u rack rack wall mountable or floor standing with 650va line interactive ups , armoured 6 core ofc cable , 4 pair cat6 cable , wireless access point , installation and configuration of server , installation and configuration of switch wap and rack , installation of integrated kiosk and tablet and scanner with required accessories , laying of ofc cable with proper insulation materials like gi pipe or hdpe pipe or rubber duct covers as per site condition , laying of cat6 cable with proper insulation materials like hdpe pipe or rubber duct covers as per site condition , integration of airlines api with server and application for the verifying the passenger details , change request in hours for enhancement of the web or mobile application software
Tender For supply of consumables of cardiac catheterization lab for gbph, sri vijaya puram - puncture needles (adults), puncture needle for vascular access in adults 18 g 6- 7.5 cm long should be compatible with 0.038 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, puncture needle dedicated for radial artery access in adults 20- 22 g 3- 5 cm long should be compatible with 0.021 - 0.025 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, micropuncture needle for vascular access in adults 20- 22 g 6- 7.5 cm long should be compatible with 0.018 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, micropuncture needle for radial artery access in adults 20-22 g 3-5 cm long should be compatible with 0.021-0.025 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, introducer sheaths (adults), introducer sheath for adults and pediatrics (sizes 4 -9fr.) - standard length sizes 4- 9 fr 10- 11 cm long 0.035 or 0.038 inch guide wire compatible with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, introducer sheath with puncture needle for adults (size 5- 9 fr) - standard length sizes 5- 9 fr 10-11 cm long pack must include 18 g, 6- 7.5 cm long puncture needle 0.035 or 0.038 inch guide wire compatible with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, long introducer sheath (size 6- 7fr) 20-50 cm long sizes 6- 8fr sheath should be between 20-50 cm long 0.035 or 0.038 inch guide wire compatible with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, introducer sheath for radial access introducer sheath dedicated for transradial access sizes 4- 7 fr between 7- 16 cm long 0.021 - 0.025 inch guide wire compatible pack must include 20-22 g, 3.5 cm long puncture needle with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath m coat hydrophilic coating kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, introducer slender sheath for radial access transradial slender sheath systems 5f 10 cm capable of introducing 6f catheter with hydrophilic coating on sheath ,tapering dilator hydrophilic straight polymer 0.025 wires and 20g plastic cannula for puncture . should be fda/ce/dcgi approved, introducer slender sheath for radial access transradial slender sheath systems 6f 10 cm capable of introducing 7f catheter with hydrophilic coating on sheath, tapering dilator hydrophilic straight polymer or stainless steel 0.021 or 0.025 wires and 22 g / 20g plastic cannula for puncture should be fda/ce/dcgi approved, guidewires (adults), ptfe coated diagnostic guide wire - regular length, regular stiffness should be available in 0.025, 0.032, 0.035 and 0.038 inches size should be between 145- 180 cm long should be available as straight & j shape tip should be available in variable lengths of flexible/floppy end should be available in variable j tip sizes should be available in fixed as well as movable core, ptfe coated diagnostic guide wire - exchange length, regular stif