Tender For supply of supply- clamps and connectors - 765kv, 50ka for 1s, 3150a, cb connector suitable for al tube 4.5 inch ips, expansion type , supply- clamps and connectors - 765kv, 50ka for 1s, 3150a, isolator knee type connector suitable for al tube 4.5 inch ips, rigid type , supply- clamps and connectors - 765kv, 50ka for 1s, 3150a, isolator knee type connector suitable for al tube 4.5 inch ips, expansion type , supply- clamps and connectors - 765kv, 50ka for 1s, 3150a, isolator , rigid type connector suitable for quad aac bull conductor with horizontal approach- moving contact sidei.e. pad terminal , supply- clamps and connectors - 765kv, 50ka for 1s, 3150a, isolator , rigid type connector suitable for quad aac bull conductor with horizontal approach- fixed contact sidei.e. stem terminal , supply- clamps and connectors - 765kv, 50ka for 1s, cvt connector suitable for quad bull , supply- clamps and connectors - 765kv, 3150a, bpi connector suitable for al tube 4.5 inch ips, rigid or sliding through type , supply- clamps and connectors - 765kv, 2000a, reactor bushing connector suitable for quad bull , supply- clamps and connectors - 765kv, 3150a, parallel connector suitable for 4.5ips aluminium tube and quad bull , supply- clamps and connectors - 765kv, 1000a, pg clamp suitable for single bull to single bull
Tender For terminal connector - terminal connector, l.v. bimetalic terminal connectorfor quad zebra acsr conductor withquad conductor spacing= 150 +/- 5mmon one side and palm connector onthe other side for connector to36 kv bushing as per sketch forlv terminal connector drawing.no.34560053241, l.v. bimetalic terminal connectorfor 4" ips al tube bus terminalwith o/d 114 mm on one side andpalm connector on the other sidefor connector to 36 kv bushingas per sketch for lv terminalconnector drawing.no.34560053241, bi- metalic terminal connector foroip bushing for single acsr zebrato drg.34993050006 rev-03 tostyle-js9006280370
Tender For supply of outdoor type , plinth mounted, distribution transformer, minimum energy efficiency level 3 of rating 250 kva, 3-phase, 11kv/415-240v,50hz, oil immersed, non sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, conforming to is 1180 (part1):2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 f) of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides bushing appropriate voltage and current ratings., low voltage side cable end box required . the high voltage bushings (3 nos.) shall conform to is/ iec 60137. the low voltage bushings (4 nos.) shall conform to is 7421. off-circuit tap changer (applicable for all ratings above 200 kva) for variation of hv voltage from +5% to -10% in steps of 2.5%. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is: 1180 (part 1) latest. (ii) routine test certificates as per is: 1180 (part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d) & (e) of is:1180 (part 1) latest.
Tender For supply of 11kv and 33 kv outdoor oil cooled metering unit (combined ct and pt set) under south andaman division sub-division - supply of 11kv & 33 kv outdoor oil cooled metering unit (combined ct & pt set) under south andaman division sub-division., 11kv outdoor oil cooled ctpt combined unit 50hz three phase six bushing typewith three no. ct and one no. three phase vtwith hv neutral broughtout andearthed ilv 12/28/75 kvp ins class a, ref std refstd is16227- 1&4ct specification:ratio 80-40/5a class 0.5 burden 15va isf=7.5@ 40a stc 4ka time: 1 sec.vt specification:ratio 11kv/110v class 0.5 burden 100va voltagefactor 1.2 continuous/1.5 for 30 seconds vectorgroup/connection star/star (ynyn0). terminals: brass stud typeprimary terminals m12 in size with nut, plainwasher, spring washer & check nut. withoutterminal connector. minimum creepage distance25mm/kv.note :primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50hz three phase six bushing type with three nosct and single nos three phase vt with hvneutral brought out and earthed ilv 36/70/170 kvpins class a ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4ka time :1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 secondsvector group/connection star/star (ynyn0).terminals:terminals: brass stud type primary terminalsm12 with nut, plain washer, spring washer &check nut. without terminal connector. minimumcreepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50hz three phase three bushing three nos. ctsand one no. three phase vt with hv neutralbroughtout and earthed. ilv 36/70/170 kvp insclass a , ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4 ka time : 1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 seconds.vector group/connection star/starterminals:brass stud type primary terminals m12 with nut,plain washer, spring washer & check nut.without terminal connector.minimum creepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50 hz three phase three bushing three nos. ctsand one no. three phase vt with hv neutralbroughtout and earthed. ilv 36/70/170 kvp insclass a , ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4 ka time : 1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 seconds.vector group/connection star/starterminals:brass stud type primary terminals m12 with nut,plain washer, spring washer & check nut.without terminal connector.minimum creepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., transportation, transit,insurance, packagingcharges