Get complete information related to latest Shoe Bit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Shoe Bit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Shoe Bit Tenders.
Tender For supply of materials and erection for shifting of control room pannel at 33/ 11 kv sub station bharsawa distt. kaushambi under deposit scheme on turnkey basis under edc, kaushambi - name of work: supply, carriage & erection of materials for control room pannel shifting of shiffting of 33/11 kv s/s bharsawa distt. kaushambi, supply of centralised materials, 11 kv switch gear 600/300/5a 350 mva i/c, 11 kv switch gear 200/100/5a 350 mva o/g, 11 kv 3x300 mm2 xlpecable, 11 kv 3x120 mm2 xlpecable, 24 volt battery, 24 volt battery charger, pcc. 8.5 mtr. long for feeder, 11 kv tpmo switch with fixing clamp, 11 kv top channel, 11 kv dropper angle, earthing complete, stay set complete, 11 kv polymer pin insulator, 11 kv polymer disc insulator, 11 kv disc fiting, 33 kv control panel t/f, acsr weasel conductor, supply of de-centralised materials, 11 kv 3x120 mm2 xlpe cable jointing kit o/d & i/d, control cable 4x2.5 mm2, control cable 2x2.5 mm2, g.i. pipe 6 " dia, rubber matting, clamp with nut & bosts, earth wire clamp for pcc pole, stay clamp for pcc pole, top channel clamp pcc pole, dropper channel clamp pcc pole, g.i. strip 35x6 mm, carriage of following material, pcc pole 8.5 mtr. long., structure of la, 33kv isolator, 33 kv cts, single t/f control pannel, 33kv vcb,11 kv outgoing. incoming pannel, battery & battery charger and other associated accessiories etc. (availibility at concern store center of store division), erection work, installation of 33 kv single transformer control pannel 2 no., incoming 2 no. and 7 no. outgoing in the switchgear room and grouting the pannel by rag bolt using cement, sand mortar in ratio 1:3. work includs fitting of all accessories in all respect with complete connection of control cable with pannel. all material will be provided by the contractor except vcb and crp., construction of cable trenchs with top cover and laying of control cable for vcb, c.t. & t/f control pannel etc. as per direction of engineer. trenchs to be 12 wide and 9 deep. work includes digging, of trench, concreting of the foundation in the ratio 1:3:6 r.b. wall 9 wide with cement mortar 1:4 and plastering inside the trench in the ratio 1:3 and sand filling in the trench. all material will be provided by the contractor., earthing of 11 kv indoor equipments, switchgears as per resspo drawing. with g.i. strip of size 35x6 mm. g.i. strip fully welded at both ends and to be connected with earthmat,, erection of dp with pcc pole 8.5 mtr long with all accessaries and grouting of the pcc pole with cement, sand and brick ballast ratio 1:4:8 size 0.45x 0.45x 1.5 mtr deep under the ground as per drawing no. res-6.(cement, sand, brick, ballast shall be provided by the contractor.), installation of 24 volt battery and battery charger with cabinet in the switch gear room, by grouting base channel 100 x 50 x 6 x 1000mm. fixing of rag bolt., laying of 11 kv 3x300/3x185/ 3x120 sqmm. xlpe cable by digging 0.75 mtr. deep trench, putting layer of sand in the bottom, ramming it, laying of cable over it rmt and covering the cable from sides and top by laying bricks, finally covering the same by earth and levelling of the same, all the materials, except cable, will be pvovided by the contractor., fixing and termination of outdoor/ indoor heat shrinkable cable boxes of size 3 x300/3x185/3x120 sqmm. xlpe cable. boxes will be supplied by the contractor, sundries ( as per site requirement/emergency work), safe dismantling of 11 kv o/g pannel & received back to store, laying of weasel conductor with the help of aluminium roller by hanging three nos. on each support in a manner taking sufficient care to ensure safety of weasel conductor against rubbing on ground, precaution for safety of crops is also to be taken. the work includes jointing of conductor by providing jointing sleaves, stringing of conductor upto correct sag and binding of conductor with insulators on each support. all material shall be provided by contractor such as join
Tender For job no.1245/2026 (hew) work for repairing of children playing equipment and distempering on mature tree plants and providing and fixing of garden iron bench in pt. shri ram sharma park sector-13 at u/e rohtak with 06 months defect liability period - 11.66.1 interior finishing distempering with 1st quality acrylic distemper, having voc (volatile organic compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 1 one coat, 26.58.3 supply and installation of garden bench 3 cast iron bench of 1800 mm length, 900 mm width, 450 mm seating height, sides made of cast iron. seat and back shall be made of 10 strips of m.s. pipes 63 mm x 25 mm of 14 gauge with one m.s. flat 25 x 10 mm welded at the centre, below and back of the seat and back rest. spray painted with approved brand paint. fixed by grouting with 1:2:4 cement concrete (minimum weight of each bench 105 kg). all materials required to be as per bis specifications., job work repair of children playing equipments. , job work repair of sea saw , job work repair of bridge ladder. , job work multiplay station repairing welding and new plastic slide and top roof fiber shade any colour.
Tender For work of construction of a new 11 kv feeder for bifurcation of overloaded 11 kv chakarpur feeder under edd khatima in capital s.i. head, including supply of decentralized materials, as per tender specification. - annexure-a (supply of following material as per upcl norms.), bracing clamp for sp-55 with nut and bolt., pp & clamp with nut and bolt st pole sp-55., stay clamp for sp-55 with nut and bolt., pp & clamp with n&b st pole sp-72., pp & clamp with n&b pcc pole, 8.5 mtr., stay clamp for pcc pole., ht stay insulator., 33 kv suspension ties on every pin insutlator., ipc with aluminium bail for earthing., 11 kv ipc for covered to covered cond., 11 kv ipc for covered to bare conductor., 11 kv mid span jointing kit., 11 kv aaac covered cond. al-59, 99 sq.mm., 11 kv tension clamp with bail & ipc., annexure-b (following work as per upcl norms), chemical earthing., fabrication of steel., excavation of pit for stay set., erection of 11 kv stay set,, grouting of stay set., excavation of pit for pole., erection of single pcc pole., erectin of single sp-55 pole., erection of single sp-72 pole., erection of pcc double pole., erection of sp-55 double pole., grouting of pole., muffing of pole., painting of sp-55 pole., lopping and choppong of tree branchases., cartage of pcc pole, 51-70 k, cartage of sp-55 pole, 51-70 km., cartage of sp-72 pole, 51-70 km., cartage of petty material, 51-70 km., headload cartage of pcc pole, 0-1 km., headload cartage of sp-55 pole, 0-1 km., headload cartage o sp-72 pole, 0-1 km., headload cartage of material, 0-1 km., fixing of 33 kv suspension ties., fixing of ipc with al, bail for earting., jumpering of d/p tpmo, fuse set and t/f., jumper section pole., fixing of 11 kv 90 kn tension clamp b&ipc., fixing of 11 kv ipc for cc to cc cond., fixing of 11 kv ipc for cc to bare cond., fixing of 11 kv mid span jointing kit., laying spreading, stringing aac conductor
Tender For stage contract for supply of key materials required for maintenance of 33/11kv receiving stations along with their lines under the jurisdiction of std bijbehara during the year 2026-27 - electrical store/workshop items/: as per is standards, 11 kv vcb panel board 12 kv, 1250a, 25 ka, outdoor (incommer) as per technical specifications of rec std, 11 kv vcb panel board 12 kv, 1250a, 25 ka, outdoor (outgoing) as per technical specifications of rec std, 33 kv vcb (36 kv, 1250a, 26.2 ka, outdoor type) as per technical specifications of rec std, 33 kv c&r panel with nemurical relays with differential relay ( iec 61850), voltmeter, ammeter, annunciation windows with annunciation relays, 3-phase tri-vector meter -5 amps, dlms compliant as per technical specifications of rec std, 33 kv c&r panel with nemurical relays with out differential relay ( iec 61850), voltmeter, ammeter, annunciation windows with annunciation relays, 3-phase tri-vector meter -5 amps, dlms compliant as per technical specifications of rec std, 33 kv isolator with earthing blade (36kv,1250a, outdoor, 3 poles, 25 ka), 33 kv isolator without earthing blade (36kv,1250a, outdoor, 3 poles, 25 ka), 33 kv outdoor, oil cooled, live tank, single phase , 3 core ct set as per isi specification with accuracy class sp 10 for protection,0.5 for metering & ps for differential with ratio 800-400/5-5-5a ,600-300/5-5-5a , 500-250/5-5-5a, 400-200/5-5-5a (per set of 3 pieces), 33 kv outdoor, oil cooled, copper wound , single phase , pt set with rated primary voltage 33000/ 3 & rated secondary voltage 110/ 3 as per isi specification with accuracy class 0.5 (per set of 3 pieces)., 33 kv lightening arrestors (30 kv, 10ka, station class, zno, porcelain/polymer) gap less(per set of 3 pieces)., 33 kv post insulator (polymer/porcelain 36kv, 170kv impulse), galvanised steel structures(6" g i pipe with top,base & grouting bolts) as per rec, 11kv (e) grade armoured ,almunium,400 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium, 300 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium,240 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium, 185 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium, 120 sq mm,3-core,xlpe power cable, (std make), 2.5 sqmm 2 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), 2.5 sqmm 4 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), 2.5 sqmm 6 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), 2.5 sqmm 8 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), l t cable 3 1/2 16 sq.mm core armored , al conductor sheathed pvc insulated (std make), 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m or raychem make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 400sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 300sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 240sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 185sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 120sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for
Tender For testing of all materials used for grouting and shotcrete work supervision monitoring, documentation submitting the records and carrying out of all the field laboratory test water intake test for grouting works
Tender For testing of all materials used for grouting and shotcrete work supervision monitoring, documentation submitting the records and carrying out of all the field laboratory test water intake test for grouting works
Tender For corrigendum : repair, rehabilitation, maintenance and renovation works for bargi right bank canal at rd 6.94 km (narrai aqueduct), rd 25.425 km (rainway aqueduct), rd 30.86 km (gaur syphon) and rd 40.25 km (pariyat aqueduct) including dismantling of damaged struct - repair, rehabilitation, maintenance and renovation works for bargi right bank canal at rd 6.94 km (narrai aqueduct), rd 25.425 km (rainway aqueduct), rd 30.86 km (gaur syphon) and rd 40.25 km (pariyat aqueduct) including dismantling of damaged structures where necessary, excavation and removal of existing soil with compacted boulder backfill, construction structural components including rcc counterfort walls, gravity retaining walls, and closed barrels, and appurtenances, waterproofing works including pu grouting, epoxy treatment, polymer concrete treatment, repair and restoration of expansion joints, construction and restoration of service roads on left and right banks as per approved drawings, and river slope protection and river training works on upstream and downstream sides complete as per design, drawings and specifications of w.r.d. including all materials, labour, machinery and incidentals, as per detailed scope of work but not limited to that, on turn key basis, inclusive of 10 years operation and maintenance.