Get complete information related to latest Shunt Capacitor Bank Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Shunt Capacitor Bank Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Shunt Capacitor Bank Tenders.
Tender For comprehensive annual maintenance contract of control & relay panel incorporating numerical relays for 25 kv ac tss and shuntcapacitorbank for 01 (one) no. of tss for a period of 05 (five) years.
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For design, supply, erection, testing and commissioning of 132/27 kv traction sub-station including scada, feeding post and shuntcapacitorbank with two (02) no. 21.6/30.24 mva traction transformer at rupai in tsk division for n.f. railway, along with associated civil and s&t works and design, supply, erection, testing & commissioning of 25 kv, 50 hz, single phase, ac, electrification work of various sidings in tinsukia division " on epc mode
Tender For corrigendum : tender for rfp for engineering, procurement & construction of "design, supply, erection, testing & commissioning of 132/27 k v traction sub-station, feeding post, shuntcapacitorbank with two(2) nos of 21.6/30.24 mva traction transformers at traction sub-station imphal of n.f. railway" in epc mode.
Tender For supply and delivery of leakage materials for maintenance of water supply in vikarabad municipality under municipal general funds - supply, fixing, testing & commissioning of 200 mm diac.i. gate valves os &y as per is:14846 ( pn 10 rating) and rising spindle type with flanges, bolts, nuts, washers, gaskets etc. the valve shall be fitted with chain lock and key arrangement . , supply, fixing, testing & commissioning of 150 mm diac.i. gate valves os &y as per is:14846 ( pn 10 rating) and rising spindle type with flanges, bolts, nuts, washers, gaskets etc. the valve shall be fitted with chain lock and key arrangement . , supply, fixing, testing & commissioning of 100 mm dia c.i. gate valves os &y as per is:14846 ( pn 10 rating) and rising spindle type with flanges, bolts, nuts, washers, gaskets etc. the valve shall be fitted with chain lock and key arrangement . , supply of heavy duty long barrel copper lugs confirming to i.s specifications suitable for 400 sq.mm cable etc complete with nuts, bolts and washers makes: dmi / jainson / dowels or equivalent make as approved by the department , supply of heavy duty long barrel copper lugs confirming to i.s specifications suitable for 150 sq.mm cable etc complete with nuts, bolts and washers makes: dmi / jainson / dowels or equivalent make as approved by the department , supply of 63a 3 pole mccb, 16ka adjustable, confirms to is/iec 60947-2 having breaking capacity ------ --------ka with thermal magnetic release panel mounted. makes : lk - d sine / schneider-ns nsx/legrand -dp x3/ siemens-3v / hager-h3 / -winbreak / bch / havells / eaton , supply of 6.0 sqmm wptc (weather proof twin core) isi mark alluminium wire.makes : polycab / gm / million / vguard / gold medal / kundancab / hpl / rpg / nandicab / nakoda / payal / finecab / gemini / vimal / suncab / stanjo /rajnigandha / orbit / airson / beljin / savera champion / rhino. elec-1.6.1 , supply of 2.5 sqmm 3 core pvc / xlpe insulated sheathed multi core bright annealed bare copper conductor heavy duty industrial cables for voltage grade upto 1100 volts as per is: 694:1990 including all transportation charges etc complete. makes : nakoda / sun cab / sudhakar / powerflex / gemni / ollvin / delton / airson / hpl / beljin / savera champion /rhino. elec-1.5.6 , supply of 1.5 sqmm 3 core pvc / xlpe insulated sheathed multi core bright annealed bare copper conductor heavy duty industrial cables for voltage grade upto 1100 volts as per is: 694:1990 including all transportation charges etc complete. makes : nakoda / sun cab / sudhakar / powerflex / gemni / ollvin / delton / airson / hpl / beljin / savera champion /rhino. elec-1.5.6 , supply and erection of push buttons on the existing panel board. makes : lk / / salzar / hpl/ siemens.elec- 8.17.6 , supply and delivery of power contactor of 80apm 3 pole (ac3 rating) for heavy duty electrical power loads including all charges etc., complete , supply and delivery of nut and bolts with watchers , supply and delivery of 6mm thick rubber packing excluding all taxes. , supply & fixing of d.o.l starter 250v, single phase, 50hz. with ss enclouser comprising of contactor with bi-metalic relay with necessary push buttons, etc., complete suitable up to 3hp makes: siemens / crompton / l&t / bch. , starting capacitor of 80 to 120 mfd. by new approved make capacitor suitable for compressor motor of 1.0 / 1.5 ton a.c. unit. , running capacitor of 36 mfd by new approved make capacitor suitable for compressor motor of 1.0 / 1.5 ton a.c.unit. , reducers - od 75 mm x 90 mm , reducers - od 125 mm x 140 mm , pvc / cotton insulation tape role ( 10mtrs) , od 90 mm tee , od 90 mm - end caps , od 75 mm - end caps , od 200 mm - end caps , od 125 mm tee , ms flanges - od 75 mm , ms flanges - od 200 mm , ms flanges - od 125 mm , 7.5hp motor rewinding , 7.5hp motor pump repairs , 7.5hp motor bushes repairs , 5hp motor rewinding , 5hp motor pump repairs , 5hp motor bushes repairs , 2hp motor re
Tender For rfp for engineering, procurement & construction of "design, supply, erection, testing & commissioning of 132/27 kv traction sub-station, feeding post, shuntcapacitorbank with two(2) nos of 21.6/30.24 mva traction transformers at traction sub-station imphal of n.f. railway" in epc mode.
Tender For tender for labour charges for service and maintenance of 1.5t and 2.0t ac , labour charges for routine or breakdown service and maintenance of 8.5t ac , labour charges for service and maintenance and maintenance of vrv and vrf , labour charges for service and maintenance air waher ventilators and scrubbers , chemical and other items required for servicing of ac, vrv and vrfs , topping up with suitable cooling gas of refrigerant in ac, vrv and vrf units , replacement of running capacitor 36 mfd, 240 v of 1.5t, 2.0t and 8.5t ac , replacement of running capacitor 45 to 50 mfd, 240 v of 1.5t, 2.0t and 8.5t ac , replacement of motor capacitor 2.5 mfd, 240 v of 1.5t, 2.0t and 8.5t ac , replacement of motor capacitor 4 mfd, 240 v of 1.5t, 2.0t and 8.5t ac , replacement of indoor fan motor of 1.5t, 2.0t and 8.5t ac , replacement of outdoor fan motor of 1.5t, 2.0t and 8.5t ac , replacement of condenser coil of 1.5t, 2.0t and 8.5t ac , replacement of cooling coil of 1.5t, 2.0t and 8.5t ac , supplying and replacement of pcb for 1.5tr and 2.0 tr inverter ac , supplying and replacement of pcb for 8.5 tr ac , repairing of pcb for 1.5tr and 2.0 tr inverter ac. , repairing of pcb for 8.5 tr inverter ac. , replacement of old burnt or defective compressor 1.5 tr ac compressor , replacement of old burnt or defective compressor 2 tr ac compressor , replacement of old burnt or defective compressor 8.5 tr ac compressor , replacement of magnet switch for vrv and vrf , replacement of motor capacitor 2-5 mfd, 240 v for vrv and vrf , replacement of motor capacitor 4 mfd, 240 v for vrv and vrf , replacement of outdoor fan motor for vrv and vrf , replacement of condenser coil for vrv and vrf , replacement of cooling coil for vrv and vrf , replacement of old burnt compressor for hot and cold type vrv and vrf , repairing of 8 to 12.5 hp monoblock pumps , repairing of 1 to 2 hp monoblock pumps , repairing and re-installation of starters for various pumps in air ventilators , replacement of old burnt starters for various pumps in air ventilators , replacement of old burnt connectors and contactors for pumps //bid details 2 / 33