Tender For insulation monitoring relay (imr) to monitor 3 phase power supply of voltage range 110v ac,measuring range 1-100 kohm, control voltage 24-240vac/dc output 1c/0(spdt) contact system leakage capacitance 10 micro farad as per contrel model no.ir 140y-4, ri-r22 (or)abb model no.cm.iws.1s (or)schneider model no.vigil ohm/imd-im10 (or) siemens model no.3ug4581-1aw31 (or)dold model no.il5880.12 (or)bender (or)woka. accepted makes : contrel/abb/schneider/siemens/dold/bender/woka. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of uhv deposition chamber - uhv chamber specification (vacuum better than 2 10-9 mbar uhv) chamber overview spherical (diameter 14 ) or equivalent square shaped uhv chamber with support frame equipped with three (3) x 2-inch magnetron sputtering sources. all cf flanges and uhv viewports/ss blanks, three (3) x 2-inch magnetron sputtering sources. each sputtering source has an individual gas inlet line for process gases. all cf flanges., substrate holder : diameter: 2 inches; heating molybdenum heater capable of heating substrate (a) from room temperature (rt) to 800 c during rotation and (b) from room temperature to 1000 c without rotation. rotation: substrate holder can rotate continuously, driven by a stepper motor. variable speed from 0 to 10 rpmmovement: up / down vertical movement of total 25mm to adjust substrate position during deposition sputtering geometry: one sputtering source mounted parallel to the substrate surface, tilt adjustable. two sputtering sources mounted confocally at an angle relative to the substrate. base pressure: lower than 2 10 mbar (ultra-high vacuum)., vacuum pumping system: turbo molecular pump: pfeiffer hipace300 / edwards next 300 / leybold turbovac 350i with cf100 flange or equivalent with integrated controller, ion pump with controller: included to maintain uhv vacuum levels and provide clean pumping., backing pump: pfeiffer hiscroll 12 / edwards nxds 15i / leybold scroll vac 15 plus or equivalent dry scroll pump used to back tmp, gate valves : one cf100 and one cf150 manual gate valves for isolating the chamber from the pumping systems as well as throttling, vacuum gauges and measurement: one cold cathode gauge with readout capable of measuring vacuum pressures down to1 10-10 mbar for precise uhv monitoring., one capacitance manometer gauge with measurement range from 1 10-1 to 1 10 mbar for accurate pressure reading during deposition phase, gas delivery system: two independent mass flow controllers (mfcs):a. one mfc (0-100 sccm) for argon gas feeding to all three sputtering sources via high vacuum valves.b. one mfc (0-100 sccm) for nitrogen gas feeding directly into the chamber with its own high vacuum valve.gas lines for ar and n2 are physically separated to avoid cross-contamination., chamber access and viewports: 1. two view ports installed on the chamber, each equipped with manual shutters. 2. access ports for gauges, pump, gas inlet and few spares for future upgradation., baking capability: entire chamber designed to bake-out at 150 c to reduce contamination and out gassing during operation, cooling capability : water manifold with flow switch / flow meters, near uhv chamber specification: chamber overview: spherical (diameter 14 ) or equivalent square shaped uhv chamber with stand., three 2-inch magnetron sputtering sources, each with individual gas inlet. all cf flanges and uhv viewports/ss blanks., substrate holder: a. diameter: 2inches; heating : molybdenum heater capable of heating substrate (a) from room temperature (rt) to 800 c during rotation and (b) from room temperature (rt) to 1000 c without rotation b. rotation : substrate holder driven by stepper motor. variable speed from 0 to10 rpmmovement: up / down vertical movement of total 25mm to adjust substrate position during deposition sputtering geometry: one sputtering source mounted parallel to substrate surface (tilt able preferred). two sputtering sources mounted confocally at an angle. base pressure : lower than 5 10 mbar (near uhv)., vacuum pumping system: turbo molecular pump : pfeiffer hipace 700 / edwards next 730 / leybold turbo vac 900 ix or equivalent with cf100 flange and integrated controller, suitable for near uhv vacuum., backing pump: pfeiffer hi scroll 12/edwards nxds15i / leybold scroll vac 15 plus or equivalent dry scroll pump used to back tmp, gate valves: one cf150 manual gate valve to isolate / throttle chamber from pumping system, vacuum gauges and measurement: cold cathode readout capable of dis
Tender For a/r & m/o of residential and non residential building (excluding crp building i.e. opd, ipd and a&e block) of lhmc & associated hospitals new delhi for the year 2025-26. (sh-providing of digital data transmitter with capacitance base battery powered of data signal at ksch building)
Tender For supply of insulation monitoring relay 110v ac, measuring range 1 k ohm to 100 k ohm, control voltage range 24-240v ac/dc, output 1c/o (spdt) contact, system leakage capacitance 10 micro farad. conforming to rdso specification no. rdso/pe/spec/ac/0184-2015 (rev-1), used for insulation control 110v of lhb type ac coaches, accepted make & cat. no.: as per sr. no. 67 of the common bom list issued vide rdso letter no. el/7.1.108/mssbc dated 17.09.2021 [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : sp/b957-000-yl-mr-1236/138 sp. level instruments (tuning fork and capacitance) for bina petchem and refinery expansion project (bprep) of m/s bharat petroleum corporation limited (bpcl)
Tender For purchase of equipment for electronics and communication department - 100mhz/2 channel digital storage oscilloscope(dso), sample rate 1gsa/s, record length - 14mpts, wavwform capture rate-400,000 wfm/s, serial decode/trigger functions, advanced math operations-fft, d/dt, integrate, square root 38 parameters automatic measurements, 7 inch tft lcd display, newest generation of spo(super phosphor oscilloscope) technology support usb host, usb device (usb tmc), lan (vxi-11), gpib (optional), pass/fail, trigger out, impts, 500uv/div sensitivity, 2 channel 3mhz function generator with modulation, 3 mhz function generator with sine, square, triangle, ramp, pulse, ttl & dc, frequency range 0.3hz to 3mhz, amplitude and frequency display, internal and external modulation by any signal by am,fm,pwm,pam,fsk,ask, auto ranging 40mhz frequency counter, auxiliary generator with frequency 20hz-20khz, square wave rise time- better than 50ns, dual channel power supply 0-30v continuous variable regulated 30v-2a, 0 to +/- 15v-1a, 5v-5a multiple power supply, dc 0 to 30v/2a, 0 to +/- 15v/1a tracking, 4.5 to 5.5 / 5a digital display for voltage and current protection against overload and short circuit, adjustable current limiter, constant current & constant voltage, multimeter - digiital - dc voltage 1000v, ac voltage 1000v, dc accuracy +/- 1% +3 digit, current dc 10amp, ac 10 amp, dc accuracy +/- 1.5%+3 digit, ac accuracy +/- 1.5% +3 digit, resistance 40 mohm - resistance accuracy +/- 1.5% +3 digit, capacitance :1000uf; capacitance accuracy +/- 5% + 5 digit. cat iii 600v saftey rating, bigger display with bright white backlight. over voltage indicator, frequency and temperature measurements, voltage, resistance, continuity, capacitance measurements, input terminal for ac and dc current measurements upto 10a, diode test, data hold, min/max ammeter and voltmater included.
Tender For supply of m p p film wound cap element with zinc spray at both ends cleared for hvdc hvac and tested against defined capacitance and tan parameter 2.5 mfd 6.5 mic x 37.5mm