Get complete information related to latest Sieve Analysis Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Sieve Analysis Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Sieve Analysis Tenders.
Tender For supply of carrying out soil investigation at work site by drilling , drilling and sampling in soil and rock , conducting standard penetration test. , natural moisture content. , dry and wet density , soaked unconfined compression test. , percentage absorption. , mechanical analysis and moisture content. , liquid and plastic limit test. , sample preparation , sieveanalysis , soil classification as per is. , direct shear test. , consolidation test. , unconfined compression on rock. , completion of field and laboratory test as required for compiling , submission of 08 copies of soil investigation report along with photos , type of foundation recommended
Tender For carrying out soil investigation at work site by drilling , drilling and sampling in soil and rock , conducting standard penetration test. , natural moisture content. , dry and wet density , soaked unconfined compression test. , percentage absorption. , mechanical analysis and moisture content. , liquid and plastic limit test. , sample preparation , sieveanalysis , soil classification as per is. , direct shear test. , consolidation test. , unconfined compression on rock. , completion of field and laboratory test as required for compiling , submission of 08 copies of soil investigation report along with photos , type of foundation recommended
Tender For supply of 1) atterberg limits (is: 9259-1979). plastic limit (pl) the water content at which the soil changes from a semi-solid to a plastic state.2)cube testing machine digital 1500 kn. digital cube testing machine with self calibration is a precision laboratory instrument used to test the compressive strength of concrete cubes. (is 14858:2000) equipment should be as per is specification.3)sieveanalysis gi sieves 45 cm dia [40 mm, 20mm, 10mm,12.5 mm, 6.3 mm. aggregate sieveanalysis, used to determine the particle size distribution of coarse and fine aggregate.4)specific gravity bottle of 1 kg capacity. a specific gravity bottle, determine the density of liquids or solids by measuring their mass and volume5)universal automatic mechanical compaction machine universal mechanical compaction machine is motorized lab device used to compact soil samples (is:10074)6)wet and dry sieveanalysis[40mm,20mm,10mm,4.75mm,2mm,600mic.,425mic,212mic,75mic] wet and dry sieveanalysis used to determine the particle size distribution of granular materials 45 cm dia ( is: 460 - 1962)7)distilled water plant. a distilled water plant, produce high-purity distilled wate. this pure water is essential for laboratory applications where contamination-free water8)heavy duty compaction equipment (is:9198 & is:10074) heavy duty modified proctor compaction test apparatus with moulds , used to compact soil samples in moulds of 2250cc and 1000cc with rammer
Tender For replacement of asbestos sheet roof into galvalume sheet roof for material testing lab and surface treatment chemical storage building including minor renovation works at iprc, mahendragiri. /electrical work/
Tender For supply of consultancy for demolition and construction of rcc overhead tank with associated works at 505su c c - to carryout the test to ascertain in soil profiles , 150mm dia bore holes as per latest is specification , no of bore hole 02 nos , depth of each bore holes 15 mtr , collection of disturbed and undisturbed soil sample , conducting lab test on disturbed soil samples , sieveanalysis , atterbergs limit , natural moisture content , particle size analysis test , bulk density , conducting lab test on undisturbed soil samples , specific gravity , free swell index and swelling properties of soil , organic mater in soil if any , consolidation test compressed index value , triaxial compression test and determination of shear parameters , harmful salt complete investigation as already ref , note a submission of four copies of test reports with detailed description , design comma preparation and submission of architectural drawings comma structural drawings comma detailed estimates for a rcc overhead tank , rcc overhead tank of 10000 gallon capacity , rcc framed construction on permanent specifications should be considered for the subject bldg , staging height of the 15m from gl , rcc dome should be designed , note a analysis and designing shall be done at staad pro structural software , note b preparation of structural drawings comma plan section and other details all as per latest is 456 and is 13920 of bis , note c structural design or drawings shall be vetted from iits or nits , note d concrete grade for designing shall be m30 and grade as steel shall be fe500 or fe 500d or crs bars as specified in relevant is codes , note e the soil investigation report shall be given to department for the foundation design of the buildings , note f the design folder with original tracings of design or drawings shall be submitted , preparation of boq and estimate comma rate analysis and yardstick ) /bid number: gem/2026/b/7255157 * /dated: 06-03-2026 & & / bid document1 / 25