Tender For supply erection installation and commissioning of heavy duty 25 hp 75hp 90 hp vfd panel - supply, erection, installation and commissioning of vfd panel with all protections and indications & suitable for 25 hp, 960 rpm, 3 phase squirrel cage induction motor for cane unloader. vfd make abb/siemens/yaskawa.(01 no), supply, erection, installation & commissioning of heavy duty vfd panel with all protection, indications and suitable for 75 hp, 1475 rpm, 3-phase squirrel cage induction motor application for primary cane carrier and secondary cane carrier drive. including accessories one start-stop switch, local/remote switch with potentiometer for varying rpm including proper wiring from remote switch to main vfd panel. the drive must be arrangement to synchronized with plc system of our primary & secondary cane carrier. vfd make abb/siemens/yaskawa. (02 nos.), supply, erection, installation and commissioning of heavy duty vfd panel with level sensor with all protections and indications & suitable for 90 hp, 1440 rpm, 3 phase squirrel cage induction motor for raw juice pump motor. including accessories one start-stop switch, local/remote switch with potention meter for varying rpm including proper wiring from remote switch to main vfd panel. vfd make abb/siemens/yaskawa. (01 no.), a.e. (elactrical) chief engineer
Tender For servicing and annual maintenance contract of vfd drives acb plc system complete installed field instruments of 02 nos texmaco make 30 tph boiler up3644 and up3645
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; electrical system or installation, comprehensive biennial maintenance contract for delta make vfd for all weather pump motors; service provider
Tender For vfd cum motor controls for cooling water (cw) system of three nos generating units of rampur hps and integration with existing plcs and plant scada & thereafter 2 (two) year of guarantee/ warrantee periods from the date of successful completion of work
Tender For corrigendum : supply of supply of vfd 1200kw/690v/3ph/ip42 supply of vfd 1200kw, 690v, 3ph, ip42 ingress protection panel c , supply of ac induction motor supply of ac induction motor 1200kw, 3ph, 690v, water or oil cooled, co , supply of plc panel and scada supply of plc panel and scada for drive & motor control, system contro , nstallation, commissioning & testing of vfd, motor, plc, scada as per edt-2149
Tender For corrigendum : rate contract for annual maintenance of the hvac supplied by m/s stulz-chspl(india) pvt. ltd. for cooling of vfd system of kd-kr at wrpl, koyali for 3 years
Tender For corrigendum : custom bid for services - rpnc252027 support service for swing extruder vfd installation-shifting, foundation and installation of power transformer- 1. the power transformer is to be installed by construction of new transformer foundation, dismantling/modification of surface, providing chain link fencing on all other 4 sides, cleaning and refurbishment of bay area is in the scope of contractor only. all necessary manpower, tools & tackles, shifting machinery like hydra/crane etc shall be in the scope of contractor only. 2. shifting of power transformer of 7.2 mva onan from store to site, loading-unloading, erection, site storage are in scope of contractor. 3. the basic data sheet and ga drawing of the proposed transformer is attached in scope only. 4. the bidder if required must construct bay width, height and fire walls as per relevant is/iec/oisd standards and site conditions such that adequate clearances for maintenance shall be maintained. bidder to submit the plot plan of equipment layout of transformer layout along with the bid. the bidder shall carryout the site visit for assessment of the available installation space. the total length of the transformer bay should be such that the radiator can be accommodated on either side of transformer tank in the specified bay width. 5. all necessary earth pit provisions, & fire barriers/wall modifications, provision of new hvws water sprinklerbased firefighting system having suitable capacity for protection against the fire & explosion as per the design of supplied transformer and applicable standards & direction of eic. provision of all necessary fire protection system for transformers shall be in the scope of lstk contractor. 6. construction of oil drain facility of transformer as per is standard and hookup with existing burn oil pit. 7. the erection to be certified by contractor as per its recommended procedures which is to be submitted prior to erection. qap for erection and site commissioning shall also to be endorsed by contractor. 8. all kind of lifting, rigging work for loading-unloading, erection work including supply of hydra/ cranes, lifting rigging materials, manpower, tools and tackles as required are in scope of contractor. 9. all kind of skilled, semi-skilled, unskilled manpower as per itc of transformer requirement will be in the scope of contractor. 10. erection includes entire vacuum by proper capacity of vacuum pump, for not less than 48 hours, or more if required as per the instruction of engineer in charge. 11. first filling up of the transformer oil at site, its filtration, site testing oil sample, any refiltration required during final commissioning shall be in the scope of contractor including all tools, tackles and including oil filtration machines. oil may be supplied in drums, which should be properly sealed during transportation and storage. seal shall be verified and opened in front of iocl representative before filling in transformer. contractor should have enough storage capacity for handling oil. filling the oil from drums to the transformer through suitable capacity of high-quality filter machine and filtration of the same to get desired bdv &ppm as specified by engineer in charge and transformer manual. 12. contractor must replace all the gaskets by new ones if required by engineer in charge. 13. the contractor shall arrange nitrogen cylinder required at site for above work. 14. contractor must repaint the transformer tank with two coats of anti-rusting good finish ltbs grey shade 631 of is:5 by spray painting if required and as per the direction of engineer in charge..
Tender For procurement of hvac items components and accessories at acem under emu r and d nasik - d scaling for chemical, chemical, top up the gas in the refrigent working/non-functional units after pressure testing, vacuum testing, and leak testing up to required pressure and flow rate to maintain temperature etc. complete of split window/ vrf/ compressor unit of various ratings., providing & supply following field devices as per directions of engineer-in-charge., valve actuator. 50mm, level switch, float valve, thermostat, temperature sensor, pressure gauge, temperature gauge, expansion valve, volt meter, ammeter, selector switch, air dryer, indicator, compressor oil, providing laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per is 10221, refilling the trench etc. of following sizes complete as required., 80mm, 65mm, 50mm, 40mm, providing & supply following refrigerant copper tube & nitrile insulation as per directions of engineer-in-charge., 1 copper tubes, copper tubes, copper tubes, 3/8 inch copper tubes, providing & supply globe valves as per directions of engineer-in-charge., 125 mm (5"), providing & supply check valves as per directions of engineer-in-charge., 75 mm (3 "), providing, fixing and supply following size y strainers as per directions of engineer-in-charge., 50 mm (2"), 65 mm (2. 1 2 "), providing, fixing and supply following size pot strainers as per directions of engineer-in-charge., 100 mm, providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) :, 25 mm (1"), providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete :, 15 mm, 20 mm, 25 mm, providing and fixing gun metal non- return valve of approved quality (screwed end) as per directions of engineer-in-charge., 65 mm, providing, fixing and supply following electrical accessories as per directions of engineer-in-charge., mccb 100a / 415v / 50hz make and model as per existing system required., mccb 200a / 415v / 50hz make and model as per existing system required., sfu 63a / 415v /50hz fn 63 as per suitable in existing panel, sfu 32a / 415v /50hz fn 32 as per suitable in existing panel, motor protection relay range 0 - 20a/240v/50hz make minilec for existing panel, plc card, three phase monitoring relay, mod motor ll sensor, vfd 3.7 kw motor