Web Analytics Made Easy - StatCounter

Signaling Device Tenders

Get complete information related to latest Signaling Device Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Signaling Device Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Signaling Device Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45338209 Due date: 24 Jun, 202624 Jun, 2026 NA
Tender For supply and installation of linear heat detection (lhd) cable in luggage portion as per rdso spec no rdso/2013/cg-06 or latest make: sanrok. the scope of work for coach alteration (luggage compartment area):- a) provision of 20 meter. linear heat detector (lhd) cable (ul or en approved, 105110 c), junction box and connecting cable including required accessories. b) installation of latest software. c) configuration of the system to be made so that on receiving fire signal from luggage compartment the buzzer should sound and dg set should shutdown. d) configuration of the system to be made so suppression system should not take place automatically. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45336934 Due date: 02 Jun, 202602 Jun, 2026 NA
Tender For supply of electrical signal exchange system for three phase locomotive each system consists of (i) two sets of led lights, (ii) operating panel/ switches for loco pilot and assistantloco pilot separately and (iii) harnessed cable for connection] to clw specn. no. clw/ms/03/670 alt-2 or latest. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

Central Government And Public Sector

CTN :45099391 Due date: 04 Jun, 202604 Jun, 2026 NA
Tender For corrigendum : supply of meggitt make proximity probe tq702 with m16x1.5 thread & 1 meter integral cable , meggitt make proximity probe tq702 with m10x1 thread & 1 meter integral cable , meggitt make signal conditioning iqs742 for 11 meter system

CTN :45347634 Due date: 17 Jun, 202617 Jun, 2026 NA
Tender For tender for supply of vao card , door hatch sensor , vdmc , serial expension card , vrtu fan chassis , 12v power supply for vrtu , 5v power supply for vrtu , 16 slot vme chassis system , serial card rs232+rs485 tab 5 , marine isolator , battery pack for ups , ruggedized , 2.4kw dc ups power unit , keyboard , rugged panel mount 2 in trackball , gauge 48 mm 0 to 10 bar , gauge 48mm 0 to 150 c , gauge 48mm 0 to 750 c , gauge 72mm 0 to 10 bar , gauge 72mm 0 to 1250 rpm , gauge 72mm 0 to 1250 rpm with backlit , gauge 96 mm 0 to 250 rpm , gauge 96 mm 0 to 250 rpm with backlit , gauge 96 mm 20 to 40deg , top mount level transmitter normal temp , side mount leval transmitter normal temp , top leval transmitter high temp for bilge , top leval transmitter ht ss316 , side leval transmitter high temp , flood switch , totaliser for flow meter , pressure transducer (0-6 bar) , pressure transducer (0-10bar) , pressure transducer (0-250 bar) , portable operating unit , heat detector , lonisation smoke detector , optical smoke detector , marine mounting base , i.s lonisation smoke detector , i.s optical smoke detector , addressable base for is type sensors , i.s galvanic barrier , eeot - dial type for engine room , eeot gong for engine room , eeot- push button type for ops , vrtu power redundancy diode , rugged panel mount 20 1 in lcd monitor , network switch , sfp module for network switch , cctv external camera , trigger pcb transciver , modulator 25 kw transceiver , data interface & processing unit type 2 , vrtu console signal splitter (2 pole relay)

CTN :45346428 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign

CTN :45346446 Due date: 11 Jun, 202611 Jun, 2026 NA
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to

CTN :45346460 Due date: 04 Jun, 202604 Jun, 2026 NA
Tender For supply of eee lab items dept use - three phase transformer rating: 3 kva input voltage: 415 v ac, 3-phase output voltage: 230 v ac, 3-phase frequency: 50 hz winding material: copper wound insulation class: class b or higher duty: continuous duty suitable for laboratory usebench/floor mounted suitable for laboratory operation all winding terminals shall be brought out to insulated terminals and enclosed within a protective outer cover for safe laboratory operation , dc stepper motor driver kit with stepper motorinput supply : 230 v ac, 50 hz stepper motor : permanent magnet / hybrid type with suitable driver circuits. motor operating voltage : 12 24 v dc variable speed control forward and reverse direction control full step and half step operation manual / automatic pulse generation facility built-in regulated dc power supply led indication for phase sequence and status test points provided for waveform observation start / stop control switches to be provided overload and short circuit protection to be provided mounted on compact powder coated cabinet with printed circuit diagram proper insulated terminals and interconnecting leads to be provided patch chords for interconnection. , dc servo motor driver kit with servo motorinput voltage 12 - 24v, dc, 5a, 10-60rpminput supply : 230 v ac, 50 hz servo motor type : dc servo motor with feedback arrangement motor operating voltage : 12 24 v dc controller type : microcontroller based servo drive controller speed control : variable speed control to be provided position control : angular position control facility to be provided direction control : forward and reverse operation feedback device : encoder / potentiometer based feedback system built-in regulated dc power supply led indications for power and status test points to be provided for signal observation and analysis start / stop control switches provided overload and short circuit protection to be provided mounted on powder coated cabinet with printed circuit diagram proper insulated terminals and interconnecting leads to be provided , three phase resistive loadrating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , single phase induction motor with load arrangement 5hp ,230v, 1400 rpmsingle phase, 2hp,230v,1440 rpm with dol starter loading arrangement and electrical workbench mechanical rope with aluminum brake drum loading with adjustable wheels - 2 no s 0-50 kg spring balance - 2 no s electrical panel board with workbench -cupboard with door. panel board- with proper internal wiring& terminals insulated necessary symbols of motor and starter, fuse, supply indicators to be provided and printed on panel board -digital rpm indicator with proximity sensor to be provided -required number of digital ammeter , three phase synchronous motor with electrical workbench 3-phase synchronous motor with electrical workbench and loading arrangement , rating: 5 hp voltage: 440 v ac, 50 hz speed: 1500 rpm (synchronous speed), induction start using damper winding, suitable starter panel, dc supply (0 220 v dc adjustable (variable dc control) within the panel),and necessary workbench electrical panel board with workbench -cupboard with door. panel board- with proper internal wiring& terminals insulated necessary symbols of motor , starter, exciter, fuse, supply indicators to be provided and printed on panel board -digital rpm indicator with proximity sensor to be provided -required number of digital ammeters and voltmeters for motor to be provided on panel board. , synchronizing panelthree phase, 415v, 15a synchronizi

CTN :45351357 Due date: 04 Jun, 202604 Jun, 2026 NA
Tender For supply of lab equipments - purchase of lab equipments, acidity test kitspecifications:ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications, single phase resistive loadspecifications:type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability, three phase resistive load specifications:rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided, three phase capacitor bank specifications: 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated ms enclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided, 3 phase auto transformer starter specifications: 3-phase variable autotransformer input: 415 v output: 0 470 v ac (continuous) current: 15 a copper wound, carbon brush type heavy duty toroidal/core construction mounted in powder coated ms/crca enclosure front panel mounted voltage control knob with scale indication proper insulated terminals provided floor/bench mounted type suitable for laboratory use input / output terminal arrangement provided mcb/fuse protection provided proper earthing terminal provided ventilation arrangement for heat dissipation, 3 floor lift interfacing model specifications: type: table-top lift model floors: 3 levels structure: transparent acrylic / ms frame cabin: moving lift car with guide rails drive: dc geared motor / stepper motor motion: up/down movement, floor indication leds (1, 2, 3) direction indicators (up/down), start & stop atevery stage, over load limit control three-floor lift operation plc interfacing and programming floor selection logic automatic stopping at floors direction indication system educational demonstration of elevator automation, mcb elcb trainer kit specifications: 1 phase/3 phase, 2/3/4 pole, 3a-16a single pole mcb 2-5amps two pole elcb 30ma lamp load single phase 5amps panel enclosure and terminal outlets, signal generator specifications: frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vp-p. rise time: 100 ns. distortion, dso specifications: bandwidth: 50 - 100 mhz. sampling rate: 1gs/s. channels: 2 (minimum) power supply: 100v 240v ac, 50-60 hz automatic measurement: vpp, vavg,rms, frequency, period, vmax, vmin, rise time, fall time, + width, - width, +duty, - duty etc., horizontal scale: 5 ns/div 50 s/div or equivalent vertical resolution: 8 bits (2 channels simultaneously) vertical sensitivity: 1 mv/div 10 v/div (at input) waveform math: +, -, x , , invert, fft etc., waveform storage: 16 waveforms or equivalent communication interface: usb host, usb interface. 7-inch color display or equivalent input impedance - 1 m 2%, // 20 pf 2 passive probes (1x/10x), pwm based

CTN :45339269 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For 'design, supply, installation,testing and commissioning of complete earthing system for signal & telecom equipment inside main tunnels, escape tunnels, cross passages and e&m niches, etc. for tunnels t-1 to t-16 and 11 stations (section yognagari rishikesh - karnprayag) in connection with the new bg rail line project between rishikesh and karanprayag in the state of uttarakhand, india.

CTN :45337388 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For supply of lamp fixing bracket 3.15 mm thick for electrical signal exchange system as per drawing no. clw/ms/3/0670, alt-1 [ warranty period: 30 months after the date of delivery ] ]
 Loading, Please wait...

Connect us via What's Up