Tender For supply of 10 pair ug jf communication cable , station line module analog board , l3 poeplus managed switch with integrated sfp transceiver modules , 12 core sm ofc cable , hdpe pipe , 2 pair pvc telephone cable , cat 6 utp cable , pvc conduits including laying of cat6 cable and 2 pair pvc telephone cable 2000 mtrs , 24 port loaded cat 6 utp patch panel , rj11 rj45 i o boxes , 4 port spu lpu , 5a 0 25a glass fuses , cable route markers joint indicators , excavation of trenches cat 6 utp cable 2150 mtrs , laying of 10 pair armoured communication cablelaying of hdpe pipe laying of ofc cable 3250 mtrs , fixing and dressing of 12 nos of 6u network racks , 24 port fiber liu , 9u network rack , ofc patch cords of 2m length , cat6 patch cords 0f 2m length , provision of additional structured cabling in 10 work centers of cas as per scope of work , shifting of network rack end termination of telephone and cat6 cables and dressing of all cables splicing etc in e f facility , 20 pair weatherproof telephone junction boxes , open stage hfa ip phones with perpetual gateway licenses , digital handsfree telephone cli , installation commissioning programming and testing of above all items and provision of additional structured cabling for 01 year for any newly added
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; power house equipment; service provider - round the clock operation of entire signal & telecommunication(s&t) system and, routine/daily, monthly, quarterly half yearly and annual schedules maintenance of signal & telecommunication at singhpur loya s&t station as per scope of work. 2 4 round the clock operation of entire signal & telecommunication(s&t) system and, routine/daily, monthly, quarterly half yearly and annual schedules maintenance of signal & telecommunication at r&d yard s&t station as per scope of work. round the clock operation of entire signal & telecommunication(s&t) system and, routine/daily, monthly, quarterly half yearly and annual schedules maintenance of signal & telecommunication at in-plant yard s&t station as per scope of work. signalling/communication/2x25/3.5cx16/3.5cx35/3.5cx50 sqmm al pvc armoured cable, cablelaying, underground, all size and cores/ and ofc cablelaying by removing old cable from hdpe pipe and laying new cable as and when required as per scope of work.
Tender For supply of supply and laying 240 sq mm 3point 5 core ug cable , earth work excavation laying cushioning soil refilling and trench dressing work , supply installation and commissioning of electrical wiring power supply earthing work for ac units including all required accessories refer the tender document , supply installation and commissioning of electrical wiring power supply earthing work for ac units including refer the tender document , horizontal directional drilling hdd road crossing , supply, installation, testing and commissioning of following rating, wall mounted, highly energy efficient split type air conditioner 1 point 5 tr , supplying and fixing prefabricated wall hanging floor mounted type ms base frame made of 14swg ms sheet suitable for 1 point 5 tr split ac condensing unit on wall duly painted etc , wiring for circuit submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor single core cable , providing and fixing following sizes of pvc pipe with all required accessories , supply installation testing and commissioning of interconnecting soft drawn refrigerant pipe , old ac dismantling and shifting as per the direction of engineer in charge , supply laying fixing testing and commissioning of 75 sqmm cable along with guest flats strip and communication work including all accessories
Tender For corrigendum : supply and installation of telecom and scada equipments for extending data connectivity to upcoming cgd hookups and lmc connectivity in southern region on annual rate contract basis - supply items under arc for telecom system, supply of mpls tp equipment, supply of ip/mpls type switch, supply of converter, ac-dc (230 v ac to 48 v dc), ac-dc (230 v ac to 24 v dc), dc-dc (48 v dc to 24 v dc), dc-dc (24 v dc to 48 v dc), supply of battery charger with battery backup, supply of porta cabin, supply of lct, supply of equipment racks, supply of solar panel with battery back up 300 w, supply of solar panel with battery back up 200 w, supply of solar panel with battery back up 50 w, supply of explosion proof telephone, supply of weatherproof telephone, supply of acoustic half hood booth, supply of multi-paired armoured cable (10 pair), supply of 6 twisted pair, 1.5 sq. mm ( 12 core ), individual pair andoverall aluminium mylar tape shielded with drain wire, supply of 6 twisted pair, 0.50 sq. mm ( 12 core ) individual pair and overall aluminium mylar tape shielded with drain wire, supply of telemetry interface cabinet (tic), supply of analog phones, supply of fxo gateway, supply of fxs gateway, supply of ethernet switch, supply of rtu, supply of mini rtu, supply of ftc, supply of joint closures, supply of ip camera, supply of spares for telecom, supply of spares for rtu, supply of ethernet to serial converter, supply of optical to serial convereter, supply of rs 232 to rs 422/rs485 converter, supply of optical to ethernet converter, supply of out door equipment panel, supply of field mounted enclosure conforming ip-66, supply of gprs modem, supply of atex switch 8 port, supply of 24f ofc cable, supply of rtu management licenses for makes like husky, schneider, etc, telecom system (works), installation of mpls/tp equipment, integration of mpls/tp equipment with existing nms, installation and commissioning of solar system, installation of porta cabin, laying and termination of multi-paired armoured cable (10 pair), installation and configuration of converter/switch and interfacing of same with flow computer and integration with scada system, installation of tic panel, design, engineering and submission of documents, testing of ofc and submission of reports, earthing works, installation testing & commissioning of instrumentation cable, installation commissioning and integration of rtus in existing scada server, installation commissioning and integration of mini rtus in existing scada server, installation and integration of ip cameras in existing server for each cameras, installation of gprs modems if supplied as free issue, extending of leased lines for 1000 km distance including modems (one ethernet interface & one e1 interface for lan) at both ends, rectification of ofc including supply of joint pit with identification of fault and testing of of cable, installation of outdoor panel, transportation charges for free issue material (per km rate to be quoted), laying of ofc through hdd method, laying of ofc through direct trench method, point to point radio communication (2.4/5.8 ghz licence free ism band), laying of ofc cable ( if ofc supplied as free issue by gail), blowing of ofc in duct, manday charges [post-installation manday charges for rtu/telecom works on an on-call basis, including troubleshooting, system calibration, software updates, configuration adjustments, and performance optimization. ], total amount excluding gst, gst (cgst&sgst/utgst or igst) in percentage (%) on net total amount
Tender For corrigendum : supply and execution items for reliability improvement of signalling inst. section of sr. dste/1/lko of lucknow div. nr. - excavating and refilling of trench to the level of ground with rammed earth asper drg. no.(nr/s&t/con/1.1/97a) so as not to form a drain 0.3 mtrs wide & 1mtr deep on both side of the station along side the track. it shall confirm to the safe distance as per signalling and cable plan in all type of soil, it also includes clearence of roots of trees and bushes., excavating and refilling of trench 0.3 mtrs wide & 0.8 mtr deep on pitced/stone/bricks paved surface, road/crossing/platform etc. and restoration of surafce to original condition., laying of signalling/telecom/power cables of different sizes as per attached guidelines (drg. no.(nr/s&t/con/1.1/97a) or latest on signallingcablelaying and as per cable route plan approved by railways through trenches, rcc pipe, dwc pipe, gi pipe etc and meggering of cable before and after its laying of all type of outdoor cables. contractor have to transport cable from any store of lko division to site carefully. meggering to be done for each drum separately. meggering sheets to be supplied and filled up by contractor and submitted to railways, as per instructions by consignee., supply and laying of 2nd class bricks in the trench and laying as per drg. no. (nr/s&t/con./1.1/97a) or latest and as per instruction of the site engineer., boring and trenchless cabling along with supply and insertion of hdpe/dwc self lubricated pipes as per rdso spec no. rdso/spn/204/2011 ver 1.1 or latest of 120mm nominal dia in the bore at the depth of 1.4 meter to 2.1 meter from formation level (level of earth below ballast) as per drawing and as directed by engineer incharge by trenchless technology for laying of signalling /telecom/power cable under track /culvert etc. cablelaying covered separately. inspection-consignee for supply of dwc/hdpe pipe. the following required coupling arrangement should also be supplied: 1. suitable snap fit couplers withrubber o ring, 2. spacers, 3. tees. 4. bend. 5. end cap(1 no. =6mtr ,straigh tpipe). (a) the cost shall include horizontal boring through any intermediate obstruction, either natural or man made or any boundary etc. (b) the rate is inclusive of all the materials equipment and labour required for during trenchless horizontal boring under the railway track. nothing extra shall be admissible on any account than the rate quoted above. (c) the pipeis to be laid underrailway track/road /culvert. all necessary arrangement are to be provideand all precautions are to be end is not deviated from the horizontal level line by more than 250mm in horizontal and vertical direction. (d) the rate shall be inclusive of direction and protection of underground utilities encountered during boring. (e) the payment for boring shall be made only when dwc/hdpe pipe are laid in the bore., concreting unschduled items in concrete of 1:3:6 ratio in cement, coarse sand and aggregate 25mm at different places in the yard and plastering top in fine plaster of 1:4 cement sand ratio. it also includes the excavation of earth as required at site and as per instruction of site incharge. the volume in cubic metres shall include the volume occupied by any ci foundation, trestle, ms angle or flat or gi pipe required to be embedded in the casting. cement coarse sand and aggregate 25mm are to be supplied by the contractor., earth work for excavation and refilling around location boxes and signals etc. where necessary including 50m lead and 1.5m lift. the lead is to be measured from centre of gravity of location to the centre of filling and lift from main ground level. the earth work should be well rammed including breaking of clods, levelling and dressing etc. as per instruction of engineer at site., brick work with well burnt bricks in foundations and plinths with cement and sand (ordinary) mixture of 1:4 ratio. all material is to be supplied by th
Tender For supply and installation or urs at various areas of zone south, jodhpur - providing & laying xlpe insulated & p.v.c. sheathed armoured aluminium cable confirming to is :7098 p - i of 1.1 kv with h4- grade electrolytic aluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831 in existing rcc / hume / stoneware / pvc pipe/ open duct/cable trench / cable tray(with cable tie) including testing commissioning etc. as required of following size.10.0 sq. mm x 4 core, supply & installation of unified regulation system (urs) for existing street light that meets the following specification.the system must feature a 240mhz dual core processor with gsm/gprs communication capabilities and support for ota firmware updates.it should come with an internal class 1.0 energy metering system that can provide real time data of crucial electric load parameters along with fault and theft alerts.the urs must include remote load scheduling and control functionalities with a feedback time of less than seconds.the enclosure confirms to ip55 standards,and be fire retardant,weatherproof,and rustproof. the system should use a lightweight protocol for secure ,real-time communication and include cloud based software for comprehensive device management and remote control. it should be able to control single phase 5.5kw and 3 phase street light load upto 8.5kw and should come with 2pole/4pole mcb upto 25a/40a at output for short circuit protection .having a 2-year warranty urs will be installed at site as per direction of engineering incharge. (size 570*520*190mm)
Tender For bid to ras supply of centralized vrf air conditioning system for mess dining hall d d - supply, installation, testing and commissioning of vrf outdoor unit capacity 28 hp top discharge , supply, installation, testing and commissioning of vrf cassette type indoor unit capacity 2.0 tr , supply, installation, testing and commissioning of vrf cassette type indoor unit capacity 2.8 tr , refnet joints , remote , refrigerant copper pipe supply and laying suction copper pipeline and discharge line , communication cable , drainpipe , refrigerant gas , ms stand , cable tray
Tender For corrigendum : notice inviting expression of interest for selection of system integrator for addressing the tender reliability improvement of 6 quad cable by providing half grs boxes at water logging areas and between ib block sections, including trenching, cablelaying, earthing, jointing, and supply of communication accessories for the end customer.
Tender For sitc of vrv type ac - 14 hp air cooled outdoor condensing unit supply , 20 hp air cooled outdoor condensing unit supply , 24 hp air cooled outdoor condensing unit supply , 14 hp outdoor unit installation testing commissioning , 20 hp outdoor unit installation testing commissioning , 24 hp outdoor unit installation testing commissioning , 1.5 tr 4 way cassette indoor unit supply , 4 tr 4 way cassette indoor unit supply , 1.5 tr 4 way cassette indoor unit installation , 4 tr 4 way cassette indoor unit installation , 3 tr split dx cassette air conditioning system supply , 3 tr split dx ac system installation testing commissioning , centralized remote controller unit supply , centralized remote control unit installation testing commissioning , 25.4mm od copper refrigerant pipe supply , 22.2mm od copper refrigerant pipe supply , 19mm od copper refrigerant pipe supply , 15.86mm od copper refrigerant pipe supply , 12.7mm od copper refrigerant pipe supply , 9.5mm od copper refrigerant pipe supply , 25.4mm od copper pipe installation testing commissioning , 22.2mm od copper pipe installation testing commissioning , 19mm od copper pipe installation testing commissioning , 15.86mm od copper pipe installation testing commissioning , 12.7mm od copper pipe installation testing commissioning , 9.5mm od copper pipe installation testing commissioning , vrf refrigerant y and t joints with insulation supply , vrf refrigerant y and t joints installation testing commissioning , 3 core 2.5 sqmm cu shielded communication cable supply , 4 core 2.5 sqmm cu shielded communication cable supply , 2 core 1.5 sqmm cu shielded communication cable supply , 3 core 2.5 sqmm cu cablelaying , 4 core 2.5 sqmm cu cablelaying , 2 core 1.5 sqmm cu cablelaying , pvc condensate drain pipe with insulation supply , pvc condensate drain pipe installation , ms table top stands for outdoor units supply , ms table top stands for outdoor units installation , refrigerant gas r410a supply and filling , 4 core 10 sqmm xlpe armoured copper cable supply , 4 core 16 sqmm xlpe armoured copper cable supply , 4 core 10 sqmm xlpe cablelaying testing commissioning , 4 core 16 sqmm xlpe cablelaying testing commissioning , aluminium anodized partition for ac enclosure , light point wiring in pvc casing and capping , 2x2 led luminaire 24w recess surface mounted supply , led panel 2x2 24w installation testing commissioning , 4c 50 sqmm xlpe armoured copper cable supply , gi wire 8 swg supply and delivery , armoured cablelaying on wall for ac power db , 4c 50 sqmm cable end termination both ends , tpn distribution board 8 way hvac odu , fp isolator 125 amp sitc , fp mcb 63 amp sitc , fp mcb 40 amp sitc , sp and n distribution board 12 way hvac idu , dp mcb 32 amp sitc , sp mcb 6 or 10 amp sitc , sfu 100a tpn at main switch board sitc , chemical earth electrode earthing arrangement sitc , camc first year air conditioning system , camc second year air conditioning system , camc third year air conditioning system , camc fourth year air conditioning system , camc fifth year air conditioning system
Tender For laying of optical fiber cable and 6 quad in shc-srgr, ski-jyg section and provision of alternate communication in jyg-kji-khtn and bhgj-,mrij station of spj division