Get complete information related to latest Silicon Rectifier Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Silicon Rectifier Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Silicon Rectifier Tenders.
Tender For supply of step down transformer 60 kva (delta to star) capacity- input voltage 750 volts out put 415 volt ac, 50 hz, housing and fitment of transformer is as per rdso spec.no. el/eog/6/93 (rev-a)-97. and rdso drg. no.- 4251 alt. 1. suitable for pow ac pantry coach. [ warrantyperiod: 30 months after the date of delivery ] ]
Tender For supply of general electric items b b - wire 22swg , glass sleev 14 mm , slip ring for cane unloader bbl make 10 kw motor , exhaust fan 24 , plastic cooling fan for 5 00 hp motor , plastic cooling fan for 7 5 hp motor , plastic cooling fan for 10 hp motor , havells make auto cut hot air blower 2000 watt with overheat protection , soldering iron 65 watt , soldring wire , plastic cooling fan for 50 hp motor , teflon rod dia 65mm length 300mm , glass sleev 16 mm , mash rum type push button red , mash rum type push button blue , plastic cooling fan for 15 hp motor , carbon brush 12 20 32 , mettalic carbon brush 20 15 8 , carbon brush 30 20 100 , timer st 800 , carbon brush 21 31 37 , porcelean kit kat200 amp 415 v standard make , fuse wire 6 amp , fuse wire 10 amp , fuse wire 16 amp , dol starter empty box mk1 , dol starter empty box ml2 , exhaust fan 16 1 phase 960rpm ci body crompton havells make , carbon brush 20 32 40 , rocker arm 12 5 hp kec slip ring motor , h t connector 3 way , h t connector 6 way , potentio meter 500 ohm 2 w 10 turn bourns make , diode 6 amp , step down double phase transformer 415 vac to 24vdc , usha bajaj make room heater with ss reflector and body , dc solenoid coil for hydraulic grab for reverse forward direction , ss seamless ring size 1 for cane unloader , karam make industrial safety belt , silk rope 3 4 resham , foldable aluminium ladder 16 ft , amp meter 400 5 96 96 , amp meter 0 100 5 96 96 , amp meter 150 5 96 96 , limit switch 1 no 1 nc type ls 011 10 amp 500 v , frequency meter 96 96 , frequency meter digital type , air cooled resistance box for 12 5 hp 15 hp bbl make slipring motor , analog rpm meter make beacon sensor type input magnetic picup no of teeth 06 range 0 8000 rpm , selector switch for volt meter , selector switch for amp meter , volt meter 96 96 0 500 vac ae make , current transformer ct 250 5a , amp meter 300 5 96 96 , amp meter 600 5 96 96 , dyno pack with controller , current transformer ct 300 5a , current transformer ct 400 5a , current transformer ct 600 5a , current transformer ct 500 5a , current transformer ct 100 5a , carbon holder for 12 5 hp slip ring motor cane unloader motor , current transformer ct 500 1 a , amp meter 500 5 96 96 , amp meter 800 5 96 96 , porcelean kit kat 100 amp 415v , amp meter 250 5 96 96 , amp meter 1200 5 96 96 , timer 800 q 1 no 1 nc , portable single phase welding machine 220 vac , current transformer 1200 1 , current transformer 1200 5 , ictpn switch 200 amp , metravi make nctm 200 contact on contact combined digital tacho metermeter , diamond hammer drill bit size 6 mm for aluminium busbar drilling , diamond hammer drill bit size 8 mm for aluminium busbar drilling , diamond hammer drill bit size 10 mm for aluminium busbar drilling , diamond hammer drill bit size-14 mm for aluminium busbar drilling
Tender For appointment of contractor/bidder for supply of material, erection, testing & commissioning for augmentation of 72 nos. existing 33 kv sub-stations (including civil work as per site requirements) on turnkey basis under revamped reforms-based and results-linked distribution scheme- 33/11 kv s/stn. items , 12.5 mva threee phase 50 hz, 33/11 kv step down outdoor onan power transformer complete with all accessories/fittings and conforming to latest nigam's technical specification with amendments relevant iss with latest amendments., , 33kv l & e switch (630amps), , 33kv isolators (630 amps), , 33 kv vcb, 36 kv, 1250a with 1000 mva (16 ka for 1 second) rupturing capacity vcb for out door use conforming to latest nigam's technical specification no. csc-24/r-ii/uh/dh/p&d/2020-21 with relevant iss & latest amendments thereof., , 33 kv c&r panel 24 v dc operated suitable for controlling one t/fs (with differential protection) as per nigam's tech. spec., relevant iss and latest amendments., , 33kv lightening arrestor sub-stn type 30kv 10ka with surge counter., , 33kv cts 600/300/5-5-5-5 with junction box, , 33kv pts with junction box, , 33kv post insulators, , disc fitting t&c type, , 11 kv vcb rating 1250 amp. 25 ka, 475 mva rupturing capacity 24v dc operated for incoming panel i/d type, , 11 kv vcb rating 400 amp. 25 ka, 475 mva rupturing capacity 24v dc operated for outgoing panel i/d type, , 11 kv vcb rating 400 amp. 25 ka, 475 mva rupturing capacity 24v dc operated for capacitor panel i/d type, , 11kv lightening arrestor sub-stn type 9 kv 10ka (heavy duty), , 11kv ncts 900/5a, , 11 kv automatically switched capacitor apfc capacitors panal 4.8 mvar complete (with l&e switch, structure and all allied material as per nigam's tech. spec., relevant iss and latest amendments, , structure for 33 kv cts (galvanized) wt. 87.62 kg., , structure for 33 kv pts (galvanized) wt. 87.62 kg., , structure for 33 kv la (galvanized) wt. 76.38 kg., , structure for 33 kv post insulators (galvanized) wt. 76.38 kg, , structure for 33 kv isolator (galvanized) wt.288.36 kg., , structure for l&e switch (galvanized) wt.288.36 kg., , structure for 11 kv nct (galvanized) wt.92.37 kg., , structure for cable stand, , gantry tower-2xdb-2, 2xdt-2, 2xdt-3 per sub-station, , structure for 11kv la/cable stand, , acsr conductor 80 sq mm(raccoon), , acsr conductor 0.2 sq in(panther), , 11kv single core xlpe cable 630mm², , 11 kv outdoor cable boxes for s/c 630 sq mm cable, , 11 kv indoor cable boxes for s/c 630 sq mm cable, , 11 kv xlpe cable 3 c x 300 sq. mm for capacitor bank, , 11 kv outdoor cable boxes for 3c x 300 sq mm cable, 11 kv indoor cable boxes for 3c x 300 sq mm cable, gi channel 100x50x6mm (gi) various size, gi angle iron 50 x 50 x 6 mm (gi) various size, gi flat 50 x 6 mm, gi flat 75 x 8 mm for earth mat in switchyard, earthing of s/stn. with pipe & earthing plate complete with machnary chamber, g.i pipe 40 mm dia 6 mtr. long for earthing set b class, premier synthetic insulating mat (class-b as per isi 15652:2006), pg clamps for panther conductor, gi nut & bolt off size, flood light led 240 watt (ip-67 rating), aluminium die cast body (make-, crompton, bajaj, phillips and havells only), 11 meters long pcc poles, un armoured copper control cable 2c x 6mm2, un armoured copper control cable 2c x 4mm2, un armoured copper control cable 7c x 2.5mm2, un armoured copper control cable 10c x 2.5mm2, un armoured copper control cable 3c x 4mm2, un armoured copper control cable 4c x 4mm2, un armoured copper control cable 6c x 4mm2, c-wedge connector for 0.2 sq. inch. panther conductor (nom. ai area, 200mm2), 33 kv polymeric disc insulators 70/90 kn b & s type, single tension fitting for 0.2 inch2 /150 mm2 acsr conductor, wooden cleat, ni-cd alkaline battery capacity (100ah) with static battery charger as, per nigam's specification., dry chemical type fire extinguisher (5 kgs), co2 type fire extinguisher (10 kgs), dry chemica
Tender For corrigendum : supply of main siliconrectifier for 25 kv ac emu, drg. no. icf/sk-7-1-068, alt.-'j/2' to specification no. icf/elec/021/rev. 'a' ,cs-2 [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of 9 kva, 750/415/190 v ac 3 phase star star star step down distribution transformer for as per rdso spec no. rdso/pe/spec/tl/0158-2010 (rev1), type-1 [ warranty period: 30 months after the date of delivery ] ]
Tender For procurement of lab equipments for electrical and electronics engineering department - procurement of lab equipments for electrical and electronics engineering department., single phase tranformer: single phase transformer rating: 1 kva, 50 hz input: 230 v ac output: 115 v ac type: air-cooled, single-phase step-down transformer properly insulated input and output terminals brought out for safe operation, three phase transformer: rating: 3 kva input voltage: 415 v ac, 3-phase output voltage: 230 v ac, 3-phase frequency: 50 hz winding material: copper wound insulation class: class b or higher duty: continuous duty suitable for laboratory use bench/floor mounted suitable for laboratory operation. all winding terminals shall be brought out to insulated terminals and enclosed within a protective outer cover for safe laboratory operation , acidity test kit ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications, loading rheostat 3 phase: rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , loading rheostat 01 phase: type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , single phase resistive load type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , three phase resistive load: rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , three phase capacitor bank: 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated ms enclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided , on / off control of lamp using solid state relay kit type : solid state relay (ssr) trainer kit control/input voltage : 12 v / 24 v dc or up to 30 v dc output load voltage : 230 v ac, single phase load control : on/off control of ac lamp load solid state relay based switching circuit opto-isolated input control built-in ac lamp load manual on/off switching arrangement led indication for input and output status
Tender For supply of siliconrectifier cooling blower casing ( duct/dom )complete with impeller but without motor for locos.(all items of drawing/ specification except motor). specn. drg no.clw spec.clw/es/b-14 alt.c. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]