Get complete information related to latest Sirens Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Sirens Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Sirens Tenders.
Tender For corrigendum : repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and dire
Tender For supply of indoor 4 mp ir fixed dome ip camera with poe , outdoor 4 mp ir fixed bullet ip camera with poe , 16 channel nvr with network interface , 8 tb sata survelliance grade hard disk , 49 inch led monitor suitable for nvr , 16 port 100,1000 poe unmanaged switch , wall mountable networking rack 9u , cat 6 lan cable , access control unit that includes inbuilt controller,proximity card reader,fingerprint sensor,keypad and all related accessories , single electromagnetic lock with all related accessories , emergency release switch ,exit , rfid cards , 8 port 100,1000 poe unmanaged switch , installation and commissioning charges for cctv , installation and commissioning charges for acs , camc cost for 1st year after 2 years warranty , camc cost for 2nd year after 2 years warranty , camc cost for 3rd year after 2 years warranty , camc cost for 4th year after 2 years warranty
Tender For supply of indoor 4 mp ir fixed dome ip camera with poe , 16 channel nvr with network interface , 8 tb sata survelliance grade hard disk , 32 inch led monitor suitable for nvr , 16 port 100,1000 poe unmanaged switch , wall mountable networking rack 9u , cat 6 lan cable , access control unit that includes inbuilt controller,proximity card reader,fingerprint sensor,keypad and all related accessories , single electromagnetic lock with all related accessories , emergency release switch ,exit , rfid cards , 8 port 100,1000 poe unmanaged switch , installation and commissioning charges for cctv , installation and commissioning charges for acs , camc cost for 1st year after 2 years warranty , camc cost for 2nd year after 2 years warranty , camc cost for 3rd year after 2 years warranty , camc cost for 4th year after 2 years warranty
Tender For purchase of lab equipments - lab equipments, steel ceramic centre wire gauze (150x150mm ) (15x15cm), glucometer strip for one touch glucometer, rubber teats bulb type medium size, blood lancet - plastic, tripod stand : stainless steel (grade 304/1.4301, height 20 cm, 6 ring top), laboratory centre, hot plate digital, with magnetic stirrer 150 degree celsius / 302 degree fahrenheit, 100-1800 rpm, 2l capacity, 110v support stand, stir bar reriver temperature probe sensor digital rpm, timer digital timer and magnetic countdown, china dish (3 to 4 inch size), whatman no.1 filter paper (90 mm circle) 100 circles/pkt, ordinary filter paper 500 sheet / bundle (46cmx57cm), capillary tube - plain glass, non-heparinized, soft, thinwalled glass, easy to snap, length 7-10 cm, 1 mm internal diameter (200 nos/pkt) to test clotting time, haemocytometer coverslip i.e, (counting chamber has cover glass) blue star 20x25 mm no:4, english glass 20 nos/pkt, haemocytometer standard tube (round only), haemoglobinometer pipette spare 20 micro litre with rubber tube at the end, rbc pipette with marking and rubber tube at the end, wbc pipette with rubber tubes at the end, wintrobe s haematocrit tube (graduated), spirometer (portable type - compact), counting chamber (german made improved neubar). marked area should be in a mercurial background, haemocytometer set (high quality set), haemoglobinometer set including comparator std, hb tube, dropper, glass rod, w/10 hcl, brush rubber tubing with mouth part etc. (better quality set), hand grip dynamo meter material plastic, steel, electronic components lxwxh (2.4x4.1x16) style wrap, shape oval, measures upto 198 lbs (90kg) with high precision sensor for reliable results. clear lcd display shows user profile, strength level and progress tracking andeasy to read format, adjustible hand grip customizable grip size ensures a comfortable fit for all hand sizes and age of groups, long lasting perfomance with auto power off to save battery life., perimeter for laboratory liser type, mild steel (material) black coloured, dimension 350x190x170 mm (standard model), stopwatch ordinary mechanical (70x50x16cm) wt 120 gm manual winding, tuning forks to test hearing 32 hz steel model, better quality, tuning forks to test hearing 10,000hz steel model, better quality, ph meter : table top for professional laboratory ph/mv meter, 0.01 resolution +- 0.05% accuracy, research upgrade instrument, automatically identify standard buffer solution, ph 4.00, ph 7.00 and ph 10.1, user friendly, lcd display, ideal for laboratory, educational purpose, suitable for environment range from 10 degree celcius to 50 degree celcius, ph meter complete kit included comes ph meter, ph electrode, temperature sensor stand, 3 standard buffer solution, user manual for ready to use out of the box, dissection completion set - full instruments, led lamp for microcsope with variable light intensity control (substage), 1/2 circle cutting suture needle with eye, sthethoscope, bp apparatus, specimen jars (glass jar with lid) 10 inch x 6 inch x 4 inch (acrylic), specimen jars (glass jar with lid) 12 inch x 6 inch x 6 inch (acrylic), specimen jars (glass jar with lid) 4 inch x 2 inch x2 inch (acrylic), laminar airflow cabinet (vertical) stainless steel work table : filtration hepa filter, power supply 220 v, digital kitchen weighing scale with lcd display 10kgx1g precision, comparison microscope for fingerprint, x-ray view box one in four led illumination, disposable cusco s speculum-sterile clear acrilic/plastic smooth finish with silent side locking screw (s - 10, m - 10, l-10), gynaecological examinaion light led cold light source (1500 lux) 360 flexible goose neck, mobile s caster base 4500k lamb, iron / stainless steel mortar &pestle (12.5 cm diameter), tincture press stainless steel - 1l, colorimeter (digital, 400-700 nm), electric triturator, electronic balance ac aaa battery operated d = 0.01g, max : 500g, hot air oven 25l, tlc spray bottle with
Tender For corrigendum : supply of fire fighting equipment at ucspl d d - lt hand gloves , pvc clothing , resuscitator , water gel blanket , gas detectors , megaphone , safety torch , hand sirens , lt suits , ffe hoses , scba set
Tender For supply, installation, commissioning, testing, training and maintenance of instrumentation of taraka dam in mysore district of karnataka state under drip-ii (package-3) - world bank aided. - automatic water level recorder, weather station, uplift pressure measurement system, jelly filled cable, cable termination and switch box, spvc cable, laying of armoured jelly filled cable, providing and installing of digital readout unit, providing and installing of data collection unit and transmission system server, settlement plate/survey markers, data collection unit and transmission equipment, providing and installing of electronic sirens, providing installation and commissioning of tilt meters, vibrating wire piezometer/pore pressure meter, drilling of 1 mts bore holes, pair armored jelly filled cable of standard, cable termination and switch box-2, laying of armoured jelly filled cable-2, pvc pipe, v noutch, slope stability analysis, masw test to estimate dynamic soil constant, installation charges, installation charges for drainage gallery instrumentation, total station, amc
Tender For bid to ras supply of plc based fire alarm system (q3) , smoke detector (q3) , supply of material of wiring for circuit sub main wiring earth wire pvc insulated un-sheathed, copper conductor, multi standard, 1100v gd 1 core cable all as specified and directed , supply of material of addressable manual call point resettable type all as specified and alll as specified and directed , supply of material of fire alarm sounders by sirens electronic type, horizontal 1 stage continous normal operation for at least 50 minutes and all as specified and directed , supply of material of lead acid battery 12 volts, 7 ah and all as specified and directed , supply of material of ms powder coated junction box, metal gland, installation accessories like shaddle, screw, pvc sleve, cable tie etc for proper installation and all as specified and directed , commissioning and labour cost of item ser no 1 to 8 of the system all all as specified and directed in pdf specification file