Get complete information related to latest Sirolimus Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Sirolimus Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Sirolimus Tenders.
Tender For srphc82281240-coronary drug eluting stents with (1) stent on cobalt chromium alloy or platinum chromium alloy. (2) stent with coating of polymer carrier for active drug ( sirolimus everolimus or zotarolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.5mm to 4mm and length of the stent should be 12mm to 48mm. (4) the strut thickness should be 91 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapidexchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval should be enclosed in the tender bid. (9) the long term efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals. (10) the documents related to the efficacy and safety of the stent should be only for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of thestent to a major government institute. unit:no [ warranty period: 30 months after the date of delivery ] ]
Tender For hq_med_sur_zrc_zonal rate contract for supply of ph:.(153045) sirolimus eluting stent cobalt - chromium stent with abluminal coating and specialised gradient coating (no polymer coating at joint & bends). bioresorbable polymer of plcl (poly lactic acid + poly caprolactone pcl) with degradation time of 3-4 months. low concentration of sirolimus (0.8ug/mm sq) should have bio-inspired open-cell. pmda approved ]
Tender For supply of polymer free sirolimus eluting coronary stent, with microporous surface, abluminal coating, shellac resin and 10 years of safety and efficacy data. warranty: replacement warranty against any manufacturing defect noted on the o.t. table. [ai(2026-27), item code-no: s-62284, sl no.2183] ]
Tender For empanelment for the supply of cathlab items on running contract basis under kasp and other schemes of this hospital - coronary stents, des,everolimus,fda/dcgi/ce approved platinum chromium platform,polyvinylidene fluride-hexafluropropyline pvdf-hfp polymer-stent lengths8,12,16,24,28,32. stent diameter 2.25*,2.50,2.75,3.00,3.50,4.00.struct thickness 81/86 microns.nominal pressure - 11 atm,rated burst pressure 16-18 atm, des,everolimus,fda/ approved platinum chromium platform,polyvinylidene fluoride-hexafluropropylene(pvdf-hfp)polymer, des,everolimus,fda/dcgi/ce/ approved platinum chromium platform,bioabsorbable polymer plga, everolimus eluting platinum chromium stent system, des, everolimus, l 605 cobalt chromium with hybrid cell design , strut thickness- 65microns, polymer- plga diameter- 2.25, 2.5, 2.75, 3.0, 3.5,4. length- 10,13,15,18,20,24, 28, 32,36,40, 42, 44, des, everolimus, cobalt chromium strut thickness - 63 microns . diameter- 2.25,2.5,2.75,3,3.5,4. length- 8,10,13,15,18,20,24,28,32,36,40,42,44. elutes 80% of drugs along with re plga polymer in the first 20 days, dcgi approved everolimus drug eluting 65 micron strut thickness with 3 micron plla&plga. a unique proprietory coating technology basedbiodegradable polymer stent with open cell designed and flexia finished technology based cobalt chromium l605 stent.a designed for optimal strength, flexibility ,trackablity ,side branch supported,bifurcation supported and high radial strength and optimal radiopacity and excellent vessel supported stent with revers alternative link design(ral) stent, with length from 8 mm to 52 mm and diameter from 2.25 mm to 4.50 mm, ce approved everolimus eluting coronary stent system struts/cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. the cell angle is between 42 degree to 57 degree with respect to different diameter. the cells are connected by link (mid to mid pattern) with a radius of 0.2700mm. these values have been validated for lower stent profile, uniform expansion, side branch access, good trackability & strong radial support. components - drug: everolimus, stent platform: cobalt chromium l605 alloy, polymer: biodegradable, catheter: ptca rapid exchange semi-compliant stent delivery catheter. drug concentration: 1.2 microgram/mm2 of stent surface area. stent diameter(mm): 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & stent length (mm): 8, 13, 16, 20, 24, 28, 32, 36, 40, 43, 47 platinum-iridium radiopaque markers are precisely placed within the balloon cones for accurate stent positioning, also the difference between stent edge to marker is 0.5mm (atboth sides, proximal & distal) which prevents the dogboning during the angioplasty., ce approved sirolimus eluting coronary stent system struts/cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. the cell angle is between 42 degree to 57 degree with respect to different diameter. the cells are connected by link (mid to mid pattern) with a radius of 0.2700mm. these values have been validated for lower stent profile, uniform expansion, side branch access, good trackability & strong radial support. components - drug: everolimus, stent platform: cobalt chromium l605 alloy, polymer: biodegradable, catheter: ptca rapid exchange semi-compliant stent delivery catheter. drug concentration: 1.2 microgram/mm2 of stent surface area. stent diameter(mm): 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & stent length (mm): 8, 13, 16, 20, 24, 28, 32, 36, 40, 43, 47 platinum-iridium radiopaque markers are precisely placed within the balloon cones for accurate stent positioning, also the difference between stent edge to marker is 0.5mm (atboth sides, proximal & distal) which prevents the dogboning during the angioplasty., only dcgi approved everolimus eluting coronary stent system struts/cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. the cell angle is between 42 degree to 57 deg
Tender For bid to ras corrigendum : supply of biodegradable polymer coated cobalt chromium sirolimus drug eluting stent system with ultrathin 60 m , biodegradable polymer co cr sirolimus drug eluting stent with 65 microns strut thickness assorted si
Tender For srphc82281240-coronary drug eluting stents with (1) stent on cobalt chromium alloy or platinum chromium alloy. (2) stent with coating of polymer carrier for active drug ( sirolimus, everolimus or zotarolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.5mm to 4mm and length of the stent should be 12mm to 48mm. (4) the strut thickness should be 91 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapid exchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval shouldbe enclosed in the tender bid. (9) the long term efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals. (10) the documents related to the efficacy and safety of the stent should be only for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent toa major government institute.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For hq_med_sur_zrc_zonal rate contract for supply of ph:.(153047) biodegradable polymer sirolimus eluting coronary stent with stainless - steel platform having microporous surface, albuminal coating and shellac resin with diameters of 2.0 mm to 4.0 mm of varying length ]
Tender For supply of category vi cardio and interventional radio consumables - intra vascular lithotripsy balloon for coronary usage in highly clacified lesions,assorted sizes, sirolimus coated balloon,phospholipid carrier to avoid drug shedding,nanolute technology,100% balloon surfece technology,low crossing profile,assorted sizes, ptca guide wire with tip load 0.8gm and spring coil length 20 cm and one piece core wire with joint less spiring coil and slip coat (hydrophilic coating) over the 20 cm spiring coil, ptca guide wire length 180 cm with tip load 1.0 gm with polymer sleeve length 22 cm with slip coat (hydrophilic coating) and one piece core wire with joint less spring coil., ptca guide wire with tip load 0.8 gm and polymer sleeve length 16 cm with slip coat (hydrophilic coating) and diameter of wire 0.014 inch with tapered tip of outer dimeter 0.0009 inch (0.23mm)., cto ptca guide wire length 150 cm with tip load 1.7 gm and micro cone tip for superior penetration and composite core contruction with multiple wire components., inflation device (indeflator) kit for angioplasty ., high pressure 2 port manifold., angioplasty kit (insertion tool,y adaptor and torque device)., coronary control syringe with ring plunger grip 12 ml., inoue percutaneous transve-nous mitral commissrotomy balloon complete with accessories sizes-26, ptca guidewire with tip load 0.5 gm and silicon coating on distal 1.5cm and slip coat (hydrophilic coating) of 18.5 cm after silicon coating from the tip 1.5 cm with composite core contraction with multiple wire components comprising of rope coil and twist wire mounted on the core wire.
Tender For srphc82281235-coronary drug eluting stents with (1) stent on cobalt chromium alloyor platinum chromium alloy. (2) stent with coating of polymer carrier for active drug ( sirolimus, everolimus or zotarolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.5mm to 4mm and length of the stent from 12mm to 38 mm. (4) the strut thickness should be 91 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapid exchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval should be enclosed in the tender bid. (9) the long term efficacy and safety of the stent in terms oftarget vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals.(10) the documents pertaining to the efficacy and safety of the stent should be enclosed for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent to a major government institute.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]