Web Analytics Made Easy - StatCounter

Site Leveling Tenders

Get complete information related to latest Site Leveling Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Site Leveling Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Site Leveling Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45719686 Due date: 13 Jul, 202613 Jul, 2026 44.90 Lacs
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl

CTN :45733130 Due date: 15 Jul, 202615 Jul, 2026 NA
Tender For auction sale of others - u/s scrap abandoned quarter block no 71 (a-h) 8 unit type ¿i not fit for rly use. bricks 141109.00 nos approx, brick bats- 166.00 cum approx , u/s sariya, angle, xpm gate, window , fencing gate and gi pipe approx 3034 kg , u/s pvc tank, pvc cistern, ptmt tap,pillar tap approx 10 kg, u/s wooden door frame and panel/shutters approx 230 kg location ¿located at 02 bn rpsf rajhi colony under the jurisdiction of sse/w/gkc custodian - sse-w-gkc condition-1 ¿ the above lot has already been declared abandoned by the competent authority. 2 ¿ dismantling of structure by concerned purchaser on his own risk and cost, if any loss will be occur during dismantling process whole responsibility liable by purchaser. 3- the lot is on estimated basis , hence any item may be less or more 4-all useful and unusable materials on the site will have to be removed by the purchaser at his own expense. 5 ¿ after removing all the material from the site, leveling dressing and cleaning activity perform by the concern purchaser by his own risk and cost. 6- road is available 7- the lot does not include us rail and electric poles. loading by purchaser labour, delivery by lot, gst-18% ,hsn code-72044900, tcs-1%, allocation-20714208

CTN :45733131 Due date: 15 Jul, 202615 Jul, 2026 NA
Tender For auction sale of others - u/s scrap abandoned quarter block no 70 (a-l) 12 unit type ¿i not fit for rly use. bricks 214850.00 nos approx, brick bats- 252.50 cum approx , u/s sariya, angle, xpm gate, window ,fencing gate and gi pipe approx 3886 kg , u/s pvc tank, pvc cistern, ptmt tap,pillar tap approx 15 kg, u/s wooden door frame and panel/shutters approx 190 kg location ¿located at 02 bn rpsf rajhi colony under the jurisdiction of sse/w/gkc custodian - sse-w-gkc condition-1 ¿ the above lot has already been declared abandoned by the competent authority. 2 ¿ dismantling of structure by concerned purchaser on his own risk and cost, if any loss will be occur during dismantling process whole responsibility liable by purchaser. 3- the lot is on estimated basis , hence any item may be less or more 4-all useful and unusable materials on the site will have to be removed by the purchaser at his own expense. 5 ¿ after removing all the material from the site, leveling dressing and cleaning activity perform by the concern purchaser by his own risk and cost. 6- road is available 7- the lot does not include us rail and electric poles. loading by purchaser labour, delivery by lot, gst-18% ,hsn code-72044900, tcs-1%, allocation-20714208

Central Government/Public Sector

CTN :45697300 Due date: 16 Jul, 202616 Jul, 2026 20.00 Lacs
Tender For maint of road side lighting works and miscellaneous electrical items under ge n akhnoor. - labour for cutting/pruning of tree branches along security light pole around 2 mtr radius of security light fitting and removing from site including arrangement of t&p (i.e. axe, rope & ladder etc.) complete all as specified and directed., dismantling and taking down street light fittings/post top lantern/down lighter of any wattage/size for repair or replacement of burnt/worn out accessories or carrying to mes store and refixing after repair on required location complete all as directed.note: accessories or components needed for replacement shall be measured and paid separately under appropriate items., repairing of unserviceable led street light any make/model of 90 100 watt capacity by replacing compact led electronic driver suitable to operate on 120 to 270 volt, 50/60 hz ac supply, protection grade ip-66 with surge protection complete all as specified and directed., repairing of unserviceable led street light any make/model of 60 72 watt capacity by replacing compact led electronic driver suitable to operate on 120 to 270 volt, 50/60 hz ac supply, protection grade ip-66 with surge protection complete all as specified and directed., pvc conduit medium grade of size 15 mm bore including fittings, isi marked, fixing with pcc pole/steel tubular pole/garden lights/gate lights for wiring connection from pole box to light fitting and supporting with 03 nos gi strip clamp, nut & bolt, complete all as specified and directed., replacement of pvc insulated pvc sheathed stranded copper conductor cable 2.5 sqmm twin core complete all as specified and directed., pvc insulation tape of width 18 mm, thickness 0.125 mm, length 25 mtr, isi marked, for proper insulation of joints in wire where required or directed., replacement of aluminium pvc service wire 2 core 6 sqmm flat roll of 90 mtr, superior quality, complete all as specified and directed., disconnecting & dismantling of damaged/unserviceable cable of any type/make and supply & laying in repair/replacement of cable xlpe insulated, screened pvc bedded, galvanized steel strip or wire armoured electric power cables (heavy duty), 1100 volts grade with stranded aluminium conductor using lugs/ferrules at both ends of cable and testing complete all as directed for following sizes:, 10 sqmm 4 crore, 16 sqmm 4 crore, 25 sqmm 3.5 crore, 35 sqmm 3.5 crore, note for item no. 17 & 18: excavation & earth work, sand cushioning, bricks protection & gi pipe where required shall be measured and paid separately., excavation in trenches not exceeding 1.5 mtr width and not exceeding 1.5 mtr depth, getting out for electric cable complete in any type of soil complete all as specified and directed., removing surplus excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point, complete all as specified and directed., returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed., supply and laying sub class b bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed., sand cushioning with ganga sand to underground cable (8 cm thick before laying and 15 cm thick after laying the cable) complete all as specified and directed., replacement of 40 mm gi tubing light grade with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor/as garden post including 2 nos mild steel fi clamps 35 3 mm size to support pipe with pole complete all as specified and directed., boring under road horizontally of size 40/50 mm bore using gi pipe for passing of cable in road/path in hard/soft/loose soil complete all as specified and directed., applying two coats of aluminium paint over a coat of red oxide on steel tubular po

State Government

CTN :45451390 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For corrigendum : providing of handling and transport on lumpsum basis - handling & transport service, excavation

State Government

CTN :45512682 Due date: 26 Jun, 202626 Jun, 2026 NA
Tender For corrigendum : providing of facility management services - lumpsum based - brain mapping lab; painting work as per the scope of work; consumables to be provided by service provider (inclusive in contract cost),facility management services - lumpsum based - brain mapping lab; door and window work as per the scope of work; consumables to be provided by service provider (inclusive in contract cost),facility management services - lumpsum based - brain mapping lab; repairing existing wooden stage as per the scope of work; consumables to be provided by service provider (inclusive in contract cost),facility management services - lumpsum based - brain mapping lab; excavation work as per the scope of work; consumables to be provided by service provider (inclusive in contract cost),facility management services - lumpsum based - brain mapping lab; rcc work as per the scope of work; consumables to be provided by service provider (inclusive in contract cost),facility management services - lumpsum based - brain mapping lab; brick work as per the scop

CTN :45599927 Due date: 07 Jul, 202607 Jul, 2026 14.15 Crore
Tender For excavation and cement concrete lining of baitarani right bank canal (brbc) from rd 6.81 km to rd 9.00 km (balance work) including construction of structures and service road.

State Government

CTN :45598736 Due date: 25 Jun, 202625 Jun, 2026 NA
Tender For supplying and providing material- supplying and providing electric material, supplying and erecting modulartype switch6a/10a, supplying and erecting street light bracket for erection of single fitting made from 40 mm. dia 'b' class g.i.pipe 1.0 m in length, 36 watt led light sensor, 50 watt led light sensor, 36 watt led light without sensor, 50 watt led light without sensor, light bracket, pvc tapes, electric service wire , 5a switch, mcb box, 32 amp switch, armoured cable, 16 amp fuse, 32 amp fuse, pipe clamp, fitting and labour charge, providing cement concrete foundation including excavation for the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles) (16-3-2), supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5 x 3.65 x 3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no.oh-pl/stp, supplying and erecting street light bracket made from 25mm.dia 'b' class g.i. pipe 0.6m.in, supplying and erecting led street light fitting suitable for 36w to 40w led street light, including lamp,with pf > 0.95 class ip 65, supplying and erecting led street light fitting suitable for 50w lamp, including lamp, with pf > 0.95 class ip 65, supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65., supplying and erecting led street light fitting suitable for 90w led street light, including lamp, with pf > 0.95 class ip 65., supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95 class ip 65, supplying and erecting led flood light fitting of 150w, including lamp, with pf > 0.95 class ip 65, providing rental basis hydraulic bucket vehicle of hight 13 mtr. and weight capacity 200 kg with driver, oprator and disel etc.for day basis, labour charges for led fitting on street light or ms light pole., dismentaling charges led street light of pole, 1.25 mm crca sheet metal enclosures box for timmer and mcb, supplying pvc insulated pvc round sheathed 1.5 sq.mm, supplying and laying armoured cable 4c x 6 sq.mm, supplying and laying armoured cable 4c x 10 sq.mm, supplying and laying armoured cable 2c x 10sq.mm, supplying and laying armoured cable 4c x 16 sq.mm, supplying erecting & marking spmcb 6a to 32a,b-series (for lighting) 5-3-3, supplying erecting & marking dpmcb 6a to 32a, bseries (for lighting) 5-3-7, supplying and erecting programmable digital almanac timer microcontroller based with real time clock to operate on derived switching "on" & switching "off" street light as per daily sunset and sunrise respectively, supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete, supplying & erecting crimping type coper lugs for cable upto 1.5 to 6 sq mm complete, supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials.4-4-3, supplying & erecting mains with 2x1.5 sq mm f.r copper pvc insulated wire laid in provided conduit/trunking/inside pole, supplying & erecting mains with isi mark wp2 x 6sq mm 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no 8 swg 1-4-3, supplying & erecting mains with isi mark wp2 x 2.5 sq mm 1100v grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire, supplying & erecting mains with isi mark wp2 x 10.00 sq mm 1100v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire, 25 amp, 32 amp three phase l/t contactor, 2.5 sq mm multistand copper wire, insulation tape, water proof tape, street light pole box frp, cement street light pole clamp, m.s. street light pole clamp, led street light arm bend pipe, small size frp

State Government

CTN :45569676 Due date: 30 Jun, 202630 Jun, 2026 61.21 Lacs
Tender For bid document for construction of various components including transportation of p.v.c pipeline, specials for fitting, service saddle excavation, lowering, laying, jointing, refilling, job connection, encasing, valve, valve fitting, valve chamber of distribution and bore to sump pipeline, rising main sump to esr hdpe pipeline, r.c.c. e.s.r. 2,50,000 liter capacity and 18.0 mt height, house hold connection, transparency, water quality board and slogan painting works. at. mota zinzuda village water supply scheme. taluka: savarkundla, district: amreli. under augmentation tap connectivity in rural area general programme. (2nd attempt)

Central Government/Public Sector

CTN :45252253 Due date: 17 Jun, 202617 Jun, 2026 NA
Tender For corrigendum : supply of supply part for retrofitting of lt panel by supply and installation , service part for retrofitting of lt panel by supply and installation , supply of main incoming lt power distribution panels slipway , install, replace, test and commissioning of main incoming lt power distribution panels slipway , supply of welding and lighting panels slipway , install, replace, test and commissioning of welding and lighting panels slipway , supply of 3.5c x 400 sq.mm aluminum cable from substation-02 to slipway , laying, fixing, testing and commissioning of 3.5c x 400 sq.mm aluminum cable from substation-02 to slipway , supply of 3.5cx 185 sq.mm aluminum cable from slipway-2 and 3 main incoming panels to welding and lighting panels , laying, fixing, testing and commissioning of 3.5cx 185 sq.mm aluminum cable from slipway-2 and 3 main incoming panels to welding and lighting panels , supply and fitment of suitable end termination kits - straight through joints kits of required quantity to all the incoming and outgoing cables at both ends of slipway-02, slipway-03, substations, etc , providing earth pits with 75mm ci pipe as is standards , supply and laying of gi flat 50 x10 mm necessary joints with nut and bolts from earth pit to panel boards , repair and excavation of cable trench of 75mm thick up to 90cm depth , fixing of perforated cable tray on slipways 02 and 03 and securing of cables with metal ties and capping and casing to be provided , foundation for all lt panels i.e. steel foundations with concrete pedestal for panels all incoming and welding and lighting panels
 Loading, Please wait...

Connect us via What's Up