Tender For construction of cc road, retaining wall, box culvert, pitching work, borewell work & p&f high mast light and street light at cbg plant area, barbaspur korba (c.g.)
Tender For corrigendum : work for providing and laying dry stone pitching at embankment slope of railway line between railway gate and underpass along boundary wall at shree singaji thermal power project (sstpp) khandwa.
Tender For palliative restoration work to the right bank of river ganga padma for a length of 1050 m providing slope pitching and 15m length porcupine spur 30m interval at village radhakrishnapur g.p- sekendra and bilborakopra, block raghunathganj-ii and
Tender For wsp nirman karya dhanawad - excavation of earth up to a depth of 1.5 meters for foundations, trenches, drains, etc.; dressing and compacting the bed; watering; trimming the sides; removing excavated earth; backfilling voids with earth after the foundation work is complete; and disposing of surplus earth up to a distance of 50 meters. , cement concrete (1 part cement : 4 parts sand : 8 parts coarse aggregate / 1 part cement : 3 parts sand : 6 parts coarse aggregate) using 10 mm nominal size stone aggregate; including laying, compaction, curing, etc., for foundation work. , stone masonry for anicuts (check dams) using cement-sand mortar in a 1:6 ratio. , random rubble (r.r.) stone masonry in foundations and plinths using cement-sand mortar (1:6 ratio); including filling side joints/crevices, curing, etc. , stone pitching using single, hammer-dressed stones (15 to 30 cm thick), including supply and all necessary lifting/placement operations. , for culvert/bridge construction: laying/installing a single row of rcc (reinforced cement concrete) np3 hume pipes with the required gradient, using cement mortar (1:2 ratio), including collars. (excluding earth excavation, concrete, and masonry works; applicable for 450/500 mm diameter pipes). , cement plaster on walls (20 mm thick) using a 1:4 ratio mixture of cement and sand; including raking out joints and regular curing for 14 days. , cement concrete (50 mm thick) using a 1:2:4 mix ratio (1 part cement : 2 parts sand : 4 parts stone or brick aggregate of 12 mm nominal size); including mixing, laying, compaction, pressing, curing, etc. , display board and photo contingency
Tender For corrigendum : providing of facility management services - lumpsum based - hiring of santring plate, vibrator, tankar along with cement and other material; pitching work; consumables to be provided by service provider (inclusive in contract cost)