Get complete information related to latest Slaughterhouse Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Slaughterhouse Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Slaughterhouse Tenders.
Tender For supply of uhv deposition chamber - uhv chamber specification (vacuum better than 2 10-9 mbar uhv) chamber overview spherical (diameter 14 ) or equivalent square shaped uhv chamber with support frame equipped with three (3) x 2-inch magnetron sputtering sources. all cf flanges and uhv viewports/ss blanks, three (3) x 2-inch magnetron sputtering sources. each sputtering source has an individual gas inlet line for process gases. all cf flanges., substrate holder : diameter: 2 inches; heating molybdenum heater capable of heating substrate (a) from room temperature (rt) to 800 c during rotation and (b) from room temperature to 1000 c without rotation. rotation: substrate holder can rotate continuously, driven by a stepper motor. variable speed from 0 to 10 rpmmovement: up / down vertical movement of total 25mm to adjust substrate position during deposition sputtering geometry: one sputtering source mounted parallel to the substrate surface, tilt adjustable. two sputtering sources mounted confocally at an angle relative to the substrate. base pressure: lower than 2 10 mbar (ultra-high vacuum)., vacuum pumping system: turbo molecular pump: pfeiffer hipace300 / edwards next 300 / leybold turbovac 350i with cf100 flange or equivalent with integrated controller, ion pump with controller: included to maintain uhv vacuum levels and provide clean pumping., backing pump: pfeiffer hiscroll 12 / edwards nxds 15i / leybold scroll vac 15 plus or equivalent dry scroll pump used to back tmp, gate valves : one cf100 and one cf150 manual gate valves for isolating the chamber from the pumping systems as well as throttling, vacuum gauges and measurement: one cold cathode gauge with readout capable of measuring vacuum pressures down to1 10-10 mbar for precise uhv monitoring., one capacitance manometer gauge with measurement range from 1 10-1 to 1 10 mbar for accurate pressure reading during deposition phase, gas delivery system: two independent mass flow controllers (mfcs):a. one mfc (0-100 sccm) for argon gas feeding to all three sputtering sources via high vacuum valves.b. one mfc (0-100 sccm) for nitrogen gas feeding directly into the chamber with its own high vacuum valve.gas lines for ar and n2 are physically separated to avoid cross-contamination., chamber access and viewports: 1. two view ports installed on the chamber, each equipped with manual shutters. 2. access ports for gauges, pump, gas inlet and few spares for future upgradation., baking capability: entire chamber designed to bake-out at 150 c to reduce contamination and out gassing during operation, cooling capability : water manifold with flow switch / flow meters, near uhv chamber specification: chamber overview: spherical (diameter 14 ) or equivalent square shaped uhv chamber with stand., three 2-inch magnetron sputtering sources, each with individual gas inlet. all cf flanges and uhv viewports/ss blanks., substrate holder: a. diameter: 2inches; heating : molybdenum heater capable of heating substrate (a) from room temperature (rt) to 800 c during rotation and (b) from room temperature (rt) to 1000 c without rotation b. rotation : substrate holder driven by stepper motor. variable speed from 0 to10 rpmmovement: up / down vertical movement of total 25mm to adjust substrate position during deposition sputtering geometry: one sputtering source mounted parallel to substrate surface (tilt able preferred). two sputtering sources mounted confocally at an angle. base pressure : lower than 5 10 mbar (near uhv)., vacuum pumping system: turbo molecular pump : pfeiffer hipace 700 / edwards next 730 / leybold turbo vac 900 ix or equivalent with cf100 flange and integrated controller, suitable for near uhv vacuum., backing pump: pfeiffer hi scroll 12/edwards nxds15i / leybold scroll vac 15 plus or equivalent dry scroll pump used to back tmp, gate valves: one cf150 manual gate valve to isolate / throttle chamber from pumping system, vacuum gauges and measurement: cold cathode readout capable of dis
Tender For supply of materials and erection for shifting of control room pannel at 33/ 11 kv sub station bharsawa distt. kaushambi under deposit scheme on turnkey basis under edc, kaushambi - name of work: supply, carriage & erection of materials for control room pannel shifting of shiffting of 33/11 kv s/s bharsawa distt. kaushambi, supply of centralised materials, 11 kv switch gear 600/300/5a 350 mva i/c, 11 kv switch gear 200/100/5a 350 mva o/g, 11 kv 3x300 mm2 xlpecable, 11 kv 3x120 mm2 xlpecable, 24 volt battery, 24 volt battery charger, pcc. 8.5 mtr. long for feeder, 11 kv tpmo switch with fixing clamp, 11 kv top channel, 11 kv dropper angle, earthing complete, stay set complete, 11 kv polymer pin insulator, 11 kv polymer disc insulator, 11 kv disc fiting, 33 kv control panel t/f, acsr weasel conductor, supply of de-centralised materials, 11 kv 3x120 mm2 xlpe cable jointing kit o/d & i/d, control cable 4x2.5 mm2, control cable 2x2.5 mm2, g.i. pipe 6 " dia, rubber matting, clamp with nut & bosts, earth wire clamp for pcc pole, stay clamp for pcc pole, top channel clamp pcc pole, dropper channel clamp pcc pole, g.i. strip 35x6 mm, carriage of following material, pcc pole 8.5 mtr. long., structure of la, 33kv isolator, 33 kv cts, single t/f control pannel, 33kv vcb,11 kv outgoing. incoming pannel, battery & battery charger and other associated accessiories etc. (availibility at concern store center of store division), erection work, installation of 33 kv single transformer control pannel 2 no., incoming 2 no. and 7 no. outgoing in the switchgear room and grouting the pannel by rag bolt using cement, sand mortar in ratio 1:3. work includs fitting of all accessories in all respect with complete connection of control cable with pannel. all material will be provided by the contractor except vcb and crp., construction of cable trenchs with top cover and laying of control cable for vcb, c.t. & t/f control pannel etc. as per direction of engineer. trenchs to be 12 wide and 9 deep. work includes digging, of trench, concreting of the foundation in the ratio 1:3:6 r.b. wall 9 wide with cement mortar 1:4 and plastering inside the trench in the ratio 1:3 and sand filling in the trench. all material will be provided by the contractor., earthing of 11 kv indoor equipments, switchgears as per resspo drawing. with g.i. strip of size 35x6 mm. g.i. strip fully welded at both ends and to be connected with earthmat,, erection of dp with pcc pole 8.5 mtr long with all accessaries and grouting of the pcc pole with cement, sand and brick ballast ratio 1:4:8 size 0.45x 0.45x 1.5 mtr deep under the ground as per drawing no. res-6.(cement, sand, brick, ballast shall be provided by the contractor.), installation of 24 volt battery and battery charger with cabinet in the switch gear room, by grouting base channel 100 x 50 x 6 x 1000mm. fixing of rag bolt., laying of 11 kv 3x300/3x185/ 3x120 sqmm. xlpe cable by digging 0.75 mtr. deep trench, putting layer of sand in the bottom, ramming it, laying of cable over it rmt and covering the cable from sides and top by laying bricks, finally covering the same by earth and levelling of the same, all the materials, except cable, will be pvovided by the contractor., fixing and termination of outdoor/ indoor heat shrinkable cable boxes of size 3 x300/3x185/3x120 sqmm. xlpe cable. boxes will be supplied by the contractor, sundries ( as per site requirement/emergency work), safe dismantling of 11 kv o/g pannel & received back to store, laying of weasel conductor with the help of aluminium roller by hanging three nos. on each support in a manner taking sufficient care to ensure safety of weasel conductor against rubbing on ground, precaution for safety of crops is also to be taken. the work includes jointing of conductor by providing jointing sleaves, stringing of conductor upto correct sag and binding of conductor with insulators on each support. all material shall be provided by contractor such as join
Tender For corrigendum : supply of led tube light , led bulb , bulb holder , one point five mm wire bundle , switch modular roma rider , socket modular roma rider , condenser two point five oil , regulator modular , four kg abc powder refilling , six kg abc powder refilling , nine kg foam refilling , two kg water refilling , two kg co2 refilling , twentey kg for electrical room refilling , double door refrigerator
Tender For maintenance of plants, lawns and gardens of the areas around the control room, guest house, maintenance building, residential quarters and switch yard area at 400 kv ss mamidipally for the period from 01-06-2026 to 31-03-2027 (or as per actual requirement).