Get complete information related to latest Sliding Glass Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Sliding Glass Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Sliding Glass Tenders.
Tender For corrigendum : offloading work to outside agency towards replacement of broken safety glasses with denting in dozers payloaders motor graders and wheel dozers for 2 year duration at dudhichua project
Tender For supply of all purpose first aid kit , abc type fire extinguishers 2 kg capacity isi mark , thermo hygrometer temperature range 50 degree c to 70 degree c rh range -10 percent to 90 percent rh plus -minus 50 percent , temperature controller with data logging print facility for single door refrigerator with ms box , temperature controller with data logging print facility for double door refrigerator with ms box , safety glasses for multipurpose use for laboratory with hard coated lens optimal design fail proof protection
Tender For corrigendum : 5mm toughened glass lh of size: 580mm x 470mm x 5mm (for bus type window assembly with slidingglass shutters) as per icf drg. no. ls/ay/bw 5-4-003, alt-e. (cp-3 ) [note: for detailed dimensi on of toughened (plain) glass refer drg. no. judw/mech/19-695, item-03 & 04, alt-nil.(cp-2 ) firm should supply finished size glasses only, one set of sample may be got approved before bulk supply. test certificate to be provided along with supply. [ warranty period: 30 months after the date of delivery ]
Tender For supply of additional alternation work at soi d d - supply of mtrl and fabrication of overhead shed of size 20ft x 16ft , 08 x 04 inch square pipe height 10 feet , 0.5mm green laminated sheet to cover the structure , 3 inch truss to support the structure , plinth of 2 inch thickness size 21ft x 17ft , 02 x tube light havels philips , 01 x ceiling fan havels , 02 x light havels philips , granite slab of size 12ft x 3ft with 4ft height , 02 x coat of painting , 1 point 5ft wall on three side of open kitchen 20ft x 15ft , supply of mtrl and fabrication of overhead shed of size 25ft x 22ft with point 5mm green laminated sheet 02 x iron gadar of size 9 inch x 13 inch with truss to support struc of 3inch square pipe , ft side sply of mtrls and fabrication of 75ft x 5ft wall 9 inch thick 75ft x 7ft glass work 6mm 01 x slidingglass door 8ft 8mm 01 x sliding window 4 ft 8mm 02 x glass window 6 mm thick 2 way sliding , side ways supply of mtrls and fabrication of 22ft x 7ft wall 9inch thickness , back side supply of mtrls and fabrication of 75ft x 9ft wall 9inch thickness 02 windows size 5ft x 4ft 02 x door wooden size 4ft x 7ft , removal of existing window and fabrication of wooden door of size 4ft x 7ft from ante room , supply of mtrl and fabrication of false roofing size 75ftx 22ft , 10 x ceiling light 20watt orient havels , 12 x tube light havels philips , 10 x ceiling fan havels crompton , light point 06 x 15 amp and 8 x 5 amps anchor premium , replacement of existing cgi sheet , wall for gallery of size 7ft x 11ft 3ft x 7ft 2 point 75ft x 7ft and 7ft x 7ft all 9inch thickness
Tender For corrigendum : purchase of sports physiotherpy lab equipments - focused shockwave therapy the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high laser therapy should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser power output of 15 watts should have wavelengths of 810 nm & 980 nm should have an aiming beam of 650nm, should have 2 operating modes: continuous wave or pulsed applicate and piece should have embedded finger switch and light, should have a technology to customize patient treatment based on conditions, body area, body type, skin type, chronicity and absorption characteristics applicator should have a fused silica composition massage ball at the point of contact of applicator and skin. pulse frequency: 2, 10, 20, 100, 200, 500, 1000, 2500, 5000 & 10000hz pulse duration: 50% duty cycle at any given pulse frequency setting, should have a 10 hd display touch screen with password protection to reach the home screen should be supplied with 2nos. of laser protection glasses power: 100-240v, 50-60 hz the unit should be supplied with 5 different types and sizes of treatment heads (large cone, large massage ball, flat window, small massage ball, and small cone. the unit should have inbuilt battery. electrical safety class: class i, type b weight should not exceed 4 kilograms (main unit; without applicators & accessories. must have class iii also., combination therapy machine with vaccum should have 3 independent electrotherapy channels, one ultrasound channel should provide multiple clinical waveforms including interferential (2 and 4 poles and isoplanarvector), tens (asymmetric biphasic &symmetric biphasic), han, russian, vms, surged(rectangular &triangular), hvpc, microcurrent, galvanic (continuous, interrupted and low level),rabert & dia dynamic cpid/cpiso should have independent parameter adjustments for each channel including intensity, frequency, duty cycle, vector scan, channel mode, phase duration, ramp, cycle time and treatment time based on waveform should have maximum output intensity up to 140ma should have constant current and constant voltage modes should have 2 colour coded lead wires for easy picking of selected channels should have suggested electrode placement guidelines ultrasound should offer 1 and 3 mhz frequencies should have the ultrasound bnr of 5:1 or lesser should be supplied with one 5cm applicator head should have pulsed & continuous frequency modes (10%, 20%, 50% & 100%) should have variable duty cycles of 16 hz, 48 hz &1 bb 00 hz should have facility to indicate applicator uncoupling should be able to use electrotherapy and ultrasound independently and also in synchronizedcombination of electrotherapy and ultrasound, where ultrasound head functioning as bothultrasound head and electrode should have minimum