Web Analytics Made Easy - StatCounter

Smoke Detection System Tenders

Get complete information related to latest Smoke Detection System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Smoke Detection System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Smoke Detection System Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45114129 Due date: 22 May, 202622 May, 2026 25.00 Lacs
Tender For tender for supply of sitc and maintenance of addressable fire alarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop fire alarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. fire alarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the fire panel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of fire panel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the fire alarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi

Central Government/Public Sector

CTN :44789665 Due date: 18 May, 202618 May, 2026 28.24 Lacs
Tender For corrigendum : supply of fire detection and alarm system powergrid silchar sub station : : - smoke detection system , fire detection and alarm system for control room , fire detection and alarm system for switchyard panel room of 9 m length , fire detection and alarm system for 400kv gis hall , fire protection system for local relay room for gis , indoor fire detection and alarm system for fire fighting pump

CTN :45071732 Due date: 14 May, 202614 May, 2026 NA
Tender For supply of smoke detection system , installation, integration, commission

CTN :45072255 Due date: 25 May, 202625 May, 2026 NA
Tender For supply of fire alarm detection system - addressable fire alarm panel-02 loops with lcd , addressable smoke detector with base , addressable heat detector with base , addressable manual call point , addressable or conventional hooter cum strobe , addressable control modules , addressable input or output module , addressable input module , response indicator , addressable loop isolator , installation charges

CTN :45025842 Due date: 28 May, 202628 May, 2026 NA
Tender For supply, erection, testing & commissioning of training simulator for fire fitting control panel with detection system at metro railway training academy, kolkata, as per specification with 2 years warranty[ warranty period: 24 months after the date of delivery ]

Central Government/Public Sector

CTN :45037331 Due date: 13 May, 202613 May, 2026 NA
Tender For supply of fire detection panel as per sanrok part no. 2ed-255-4284 or equivalent, suitable to sanrok automatic smoke/ fire detect ion with alarm system (fds) fitted in railway coaches as per rdso specification no. rdso/2008/cg-04 (rev-6) [ warranty period: 30 months after the date of delivery ]

CTN :44538105 Due date: 29 Apr, 202629 Apr, 2026 NA
Tender For bid to ras supply of sitc control panel 10 loops , sitc control panel 4 loops , sitc control panel 2 loops , sitc of network module. the module shall connect panels and repeator panel , sitc of active repeater panel to be integrated , sitc of addressable ip67 rated multi- heat sensor , sitc of analogue addressable photo thermal smoke detector , sitc of addressable multi sensor with co detection , sitcc of response indicator on surface , sitc of short circuit isolator module , sitc of analogue addressable dual action manual call point , sitc of addressable horn strobe with a maximum output , sitc of analogue addressable supervised monitor module , sitc of analogue addressable supervised control module , supplying and laying through walls, above false ceilin , dismantling of fire alarm and detection system , supply and fixing in replacement of earth continuity conductor , dismantling of old unsv control panel , demolition of wall and ceiling board , supply and fixing of suspended system ) /bid number : gem/2026/b/7339023 * /dated: 18-03-2026 & & / bid document 1 / 19

CTN :44341415 Due date: 27 Apr, 202627 Apr, 2026 NA
Tender For bid to ras supply of refurbishment of room flooding system of server room at sauw ins satavahana c c -refilling of hfc 227ea gas 1,1,1,2,3,3,3 hepta fluro propane, zero odp, stored pressure, gas , conventional gas release panel with battery backup and cross zoning facility 2-zone with fire ext automatic mini intuitive fk-5-1-2 300gm ss sp red 79 c with nrv , ms container strap for mounting and fixing the agent containers to the wall , ul container strap for mounting and fixing the agent container to the wall , valve assembly and arrangement for supervisory switch connection for monitoring cylinder pressure, a pressure gauge with a safety burst disc and a safety cap 25 bar , pressure gauge cum switch for monitoring the cylinder pressure 0-60 bar, 22. 50 bar switch point pressure switch wasco switch point 5bar 72. 5 psig imp with fire ext automatic wm fk 5-1-12 4kg , hydro static pressure test 50 bar, inverted baker test, helium leak detection test, epoxy powder painting, dismantling, commissioning charges , conventional optical smoke detector with double dust trap chamber design, optimized performance using internal algorithm, central led for 360 status visibility, compiles to en 54-7 standard , conventional rate of rise heat detector, heat alarm threshold temperature 58 c central led for 360 status visibility, complies to en 54-7 standard and approved by lpcb, vds , installation and delivery charges

CTN :44998174 Due date: 08 May, 202608 May, 2026 NA
Tender For supply of control panel relay card as per part no. jk-fdss-1226 for automatic fire detection & suppression system of make: jk exim as per specification no. is/rdso/cg/s/22001 for power/pantry cars. [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :44966614 Due date: 13 May, 202613 May, 2026 48.00 Lacs
Tender For repair/maint of fire detection, fire alarm panel, sprinklers, smoke detectors, fire hydrants and firefighting system at chnc under ge (utilities) udhampur
 Loading, Please wait...

Connect us via What's Up