Get complete information related to latest Smoke Detector Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Smoke Detector Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Smoke Detector Scrap Tenders.
Tender For tender for supply of sitc and maintenance of addressable fire alarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop fire alarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. fire alarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the fire panel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of fire panel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the fire alarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi
Tender For supply of fire alarm system ant unit armoury and magazine c c - fire alarm panel , smokedetector , mcp , hooter flasher , 2 core 1.5sqmm cable , installation
Tender For e-tender annual maintenance contract for maintenance of fire protection fire/ smoke/heat detector system available at 400kv/220kv koradi-1 substation under 400kv rs (o&m) division koradi
Tender For supply of fire alarm detection system - addressable fire alarm panel-02 loops with lcd , addressable smokedetector with base , addressable heat detector with base , addressable manual call point , addressable or conventional hooter cum strobe , addressable control modules , addressable input or output module , addressable input module , response indicator , addressable loop isolator , installation charges
Tender For following works shall be carried out quarterly during the contract period for the two identical sets of co2 flooding system at mghe power house. the one set of system for carting to the units-1,2,3&4 and the second set of system for carting to units-5,6,7&8. i)cleaning of heat detector externaly with dry cloth ii)ensure working condition of heat detectors iii)cleaning of smokedetector externaly with dry cloth iv)ensure working condition of smokedetectors v)simulate heat and smokedetector simultaneously and check for cross zone vi)checking for leakage in pilot cylinder vii)checking the weight of co2 pilot cylindersviii)check the condition of co2 pilot hose ix)check the condition of co2 discharge hose x)inspect pressure switch and check for its functioning xi)inspect maual call points and check for its functioning xii)inspect abort switch and check for its functioning xiii)inspection of online weigh monitor and check for its functioning xiv)inspect hooter with strobe and check for its functioning xv)checking for healthiness of the battery xvi)checking the condition for slave nrv xviichecking the condition for master nrv xviii)checking of solenoids. xix)refilling of co2 cylinder and pressure testing 45 kg capacity and 4.5kg capacity (in case release of co2 gas during generator fire incidents) xx)any other work connected with the system not explicitly mentioned shall also be carried out for safe and proper operation of the system. xxi)conducting the demo of operation of the co2 flooding system twice (once in 2 quarter) during the annual maintenance contract period for kpcl staff.
Tender For supply of smoke/fire detector system as per part no : quartas 500s of advance hi-tech make only conforming to spec- rdso/2008/cg-04, rev 06. [ warranty period: 48 months after the date of delivery ]
Tender For supply of smokedetector and fire alarm system conforming to rcf specification no. edts -087 rev. b. corrigendum-1,2 or latest. [ warranty period: 30 months after the date of delivery ]