Tender For supply of details description of specification for 100 watt led flood light - led rating in warm)/system wattage/rated power, led luminaire conformity to 15:10322/part 5/section 5/2012 latest and 15: 16107, (part 2/sec 1):2012, photo biological safety of leds used shall be as per 15:16108/2012 (exempt grou, types of led luminave as per the 15: 161070part-2/sec-11/2012, types of led modules as per the 25: 16103(part 2)/2012, led rating/system wattage/rated power, luminaire system efficacy bumen/watt), ingress protection (ip rating) as per 1 10322 (part 1): 1982 latest, mounting brackets fincluded, warranty for free replacement (in year), input operating voltage range and frequency, automatic higher cut off voltage above 300 volt, rated voltage, ac power factor at hill load, driver efficiency lin sage), total harmonics distortion (in lage), the total circut power shall not be more than 110 percent of the valve declared, by the manufacturer, led chip efficacy, colour temperature (+500), working life for led (minimum 50,000 buming hours as per lm-80 report), coltur rendering index(cri), optic lenise materal (uv stabilued) (write na or without optic lense supply), heat sink should be die-cast aluminum along with sufficient heat sink fins to desipate heat effectively, capacitor shall be ratail for a temperature of 105 deg. ceblus or better, junction temperature, operating temperature range, operating humidity range, short circuit protection, overload protection, over voltage geutection, reverse polarity, high voltage test (1.5 kv for ane minute between napply terminats and body of the, unit), insulation resistance between earth and current carrying part, the luminaire shad be protected against surges and transients (internal), the luminaire shall be protected against surges and transients of >/1kv, (external, the luminaires casing/housing (single piece housing) shall be pressure de catted, aluminum alloy with higher thermal.conductivity, the lummaire body must be corrosion resistant epoxy powder couted, all fasteners must be of stainless steel, the entire housing (both led section and driver section) shall be dust and water proof having ip 66 protection as per 15:10322 (part 11:1987 latest, luminaries light transparency should be of toughened glass, toughened transparent glass cover thickness, toughened glass shall not get discolored shall not suffer degration due to heat and agning within warranty period, number of electronic control gest (power sanoles), driver components shall be industrial grade or above, pci shall be fre grade minimum 0.8 to 1.0 mm thick or mom, the luminaires works on single phase three wires system (phase, neutral and, earth, suitable connector shall be provided for led connection between driver output, and led, length of st marked three cors wire (shall be provided along with supply of, materiall, ught source, manufactures name and and brand on the aluminium die cast body, manufacturer's name, model number, serial number, date of manufactiare (month-year), and int number as identification mark inside each unit and the outside of each packaging box, the operation characteristics voltage and power be marked inside of each led, system must have emi/emc compliance as applicable (test reports shall be furnish on demand by buyer/consignee)
Tender For supply and installation of equipment of power system protection laboratory of electrical engineering lab for electrical department at bit sindri, dhanbad, jharkhand - power system protection laboratory for electrical engineering department, voltage relay uv by ov test kit, earth fault relay test kit, motor protection simulator, generator protection simulator, buchholz relay test kit, digital negative sequence current relay test kit, digital apfc relay test kit, differential relay test kit with transformer, acb air circuit breaker test kit, feeder protection simulator
Tender For 8573/e8 repair/maint of earthing, lightning protection system, painting of electrical poles, trimming of trees/bushes and connected services in all power house at basistha under ge guwahati
Tender For servicing of fire alarm system notifier honey well make and fire protection (hvws/mvws) system installed for cable galleries, control room and unit/aux transformers at supa power house
Tender For supply and installation at site ro water purifier with 5 years comprehensive warranty including consumables.# features as follows: removes excess salts, bacteria, viruses, pesticides, harmful chamicals, heavy metals, and tds from water. auto flush timer enhances membrane life by automatically cleaning at regular intervals. auto flush timer enhances membrane life by automatically cleaning at regular interval. dry run protection pump avoids unnecessary wastage of power by automatically shutting off when there is no water purifier should have electrolytic sanitization system. # techical specifications as follows: purification flow rate-25 liters/hour, inlet pressure (min/max)-0.5-2.0, rejection of salt-up to 95%, recovery of pure water- 25-30%, sediment filter-10 microns x 1, activated carbon filter- 10'', ro membrane- 1812 x 3, uv-no, dimension (l x w x h) mm- 300 x 300 x 540, power consumption- 60 watts, stage of purification minimum - 4, hn tank minimum - 8 liters, tds reduction minimum - 90%, auto cut off facility- yes, consisting tfc membrane - yes, make/brand: aquagurad/kent/zero b/blue star/usha only.
Tender For tender for supply of sitc of ip epabx system and accessories with semiskilled manpower deployment d d - sitc (supply installation testing commissioning ) of dual server gateway based ip pbx system in raid 1 storage configuration (1set equals 2 nos) , sitc of management platform inclusive of management software with liscence (1set equals 2 nos) , itc of executive ip phones with 2 way speaker phone (installation , testing and commissioning) , supply of executive ip phones with 2 way speaker phone , itc of poe based ip phones (installation , testing and commissioning) , supply of poe based ip phones , sitc of corded analog phone with cli , sitc of pc based ip operator console in raid 1 storage configuration with liscence version of software(latest) , sitc of laptop based ip operator console with liscence version os and ms office (latest) , sitc of 24 port l2 plus managed poe plus switch with fully loaded sfp modules single mode transceiver. , sitc of 16 port l2 plus managed poe plus switch with fully loaded sfp modules single mode transceiver. , sitc of 8 port l2 plus managed poe plus switch with fully loaded sfp modules single mode transceiver. , supply of cat 6a cable industrial grade including capping , casing , conduiting fasteners with all materials. , itc of cat-6a cable (for boq item 19) industrial grade including capping , casing , conduiting fasteners with all materials at various locations within aai premises.payment on actual per meter measurement basis. , supply of cat 6a utp patch cord 3 meter each. , supply of 3 core power cable 2.5mm each core. , itc of 3 core power cable 2.5mm each core.payment for laying will be on actual per meter measurement basis only. , sitc of intermediate distribution frame idf for 100 pairs. , sitc of intermediate distribution frame idf for 20 pairs. , sitc of intermediate distribution frame idf for 200 pairs. , sitc of intermediate distribution frame idf for 400 pairs. , surge protection device for idf krone type (10 pair in each krone). , supply of 0.5mm , 50 pair copper cable (armourd). , supply of 24 core core armoured single mode ofc cable. , itc (including laying) of 50 pair copper cable (0.5mm) and 24 core armoured single mode ofc cable (including capping , casing , conduiting fasteners with all materials) with hdd laying (hdd min depth 1.65 meter)payment on actual per meter measurement basis , supply of 0.5 mm , 20 pairs telephone cable. , laying of 0.5 mm , 20 pairs telephone cable. payment for laying will be on actual per meter measurement basis only. , sitc of rack mounted ups 2 kva line interactive , 30 min backup for network switches. , sitc of rack mounted ups 1 kva line interactive , 30 min backup for network switches. , sitc of fully loaded 42u rack for epabx server its accessories with cable manager 2 pdu. , sitc of rack mounted ups 5 kva online , 60 min backup for epabx servers and gateways (1set equals 2 nos) , electrical distribution system (with industrial grade mcb) as per ip epabx system requirement (min. 32 amp.) with rccb. , sitc of 3 core power cable 6 sq. mm each core. , rack mounted load transfer switch (auto changeover switch for ups output).+c37 , surge protection device spd lan. , power surge protection device spd for 5 kva ups single phase in - single phase out. , earthing system (copper strip 25mm x 3mm , 150 meters) and 6 sqmm , 100 m cable for internal distribution. , liu 24 core with pig tail (testing of fiber termination). , rj 45 patch panel 24 port. , 12u rack for poe switches & its accessories with cable manager & pdu. , io boxes with dual rj45 ports with gang box and cover. , io boxes rj45 ports with gang box and cover. , io boxes with dual rj11 ports with gang box and cover. , integration charges of all the eqpt systems associated with ip epabx mentioned in this bill of material with existing operational equipment with operational and technical training charges for 5 personnel for 3 day including all cost components. , gpr work (ground pene
Tender For corrigendum : third party audit of ongoing fire detection and protection system at anpara a 3x210mw and anpara b 2x500mw thermal power station, anpara, sonebhadra, uttar pradesh
Tender For supply and installation at site ro water purifier with 5 years comprehensive warranty including consumables.# features as follows: removes excess salts, bacteria, viruses, pesticides, harmful chamicals, heavy metals, and tds from water. auto flush timer enhances membrane life by automatically cleaning at regular intervals. auto flush timer enhances membrane life by automatically cleaning at regular interval. dry run protection pump avoids unnecessary wastage of power by automatically shutting off when there is no water purifier should have electrolytic sanitization system. # techical specifications as follows: purification flow rate-25 liters/hour, inlet pressure (min/max)-0.5-2.0, rejection of salt-up to 95%, recovery of pure water- 25-30%, sediment filter-10 microns x 1, activated carbon filter- 10'', ro membrane- 1812 x 3, uv-no, dimension (l x w x h) mm- 300 x 300 x 540, power consumption- 60 watts, stage of purification minimum - 4, hn tank minimum - 8 liters, tds reduction minimum - 90%, auto cut off facility- yes, consisting tfc membrane - yes, make/brand: aquagurad/kent/zero b/blue star/usha only.
Tender For corrigendum : supply, installation, commissioning and testing of nitrogen injection fire protection system (nifps) for 160mva and 50mva power transformer at 220/66kv ringanwada sub-station, daman.