Web Analytics Made Easy - StatCounter

Snubber Kit Tenders

Get complete information related to latest Snubber Kit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Snubber Kit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Snubber Kit Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45336407 Due date: 25 Jun, 202625 Jun, 2026 NA
Tender For supply, installation, wiring, commissioning and testing of 1.8 ton inverter 5/3 star rated wall mounted split ac along with 1/2 and 1/4 copper pipe minimum 12 ft and drain pipe with foam insulation over copper pipe with suitable size of pvc cable and connectors conforming to is 732: 2019 or latest for wiring. accepted make of ac jare blue star, hitachi, panasonic, or equivalent at new bogie conference room along with complete wiring with 1.5 sqmm and 2.5 sqmm copper pvc cable as per site requirement and shall be done with suitable wiring and protection system protected with 40a 3/4 pole residual current circuit breaker of leakage current 30 ma and overload protection with mcb conforming to is:12640 part 2 or latest and iec 60898 part 1 or latest respectively and all electrical works shall be carried out in accordance with the provision of indian electricity act 2003 land indian electricity rules 1956 amended to date and all the safety codes and procedures outlined in the safety codes shall be complied with general and safety requirementshall be governed by is 13947 (pt i) 1993 and is:8623/1993, amended to date. [ warranty period: 30 months after the date of delivery ] ]

State Government

CTN :45327429 Due date: 30 May, 202630 May, 2026 2.98 Lacs
Tender For providing and fixing of various electrical accessories at district and session court metro jodhpur - sitc of ip20 smd mid power led batten type integrated light fixture made from powder coated extruded aluminium housing with in built driver , system lumen efficacy 110 lm/watt output only at cw (5700k to 6500k) , internal surge protection of 4.0 kv with short & open circuit protection ,thd 10% , p. f. 0.95, cri >80 , life time of minimum 50000 burning hours with , 70% of intial lumen maintaned till life ends , cct 3000 k / 4000 k / 5700 k /6000 k/6500 k (as per ansi bin) as required., 1170mm(+/-10%) led batten with min. lumen output 2200 lm, sitc of ip-20 led recessed / surface mounted, round / square backlit & smd mid power led downlight with power coated die-cast aluminum housing with uv stabilized non yellowish diffuser with bis compliance 4.0 kv surge protected isolated driver, with short & open circuit protection input 320vac-48 hr protection, input 350vac-2 hr protection), having efficiency > 85% . system lumen efficacy of 110 lm / watt,at cw (5700k to 6500k) , thd 10 % , pf. 0.95, cri >80, life time of minimum 50000 burning hours with , 70% of intial lumen maintaned till life ends , cct 3000 k / 4000 k/ 5700 k /6000 k/6500 k (as per ansi bin) as required., recessed mounting, minimum lumen output 1950 lm, sitc of ip20, 2x2 led surface/ recessed mounting backlit & smd mid power type led light fixture not less than 35 mm housing depth made from crca sheet steel housing, high purity / transmissivity uv stabilized non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 v, hv cutoff - lv cutoff should be 300-100v . high efficiency with 4 kv internal surge protection bis certified isolated driver having efficiency > 85% , with short & open circuit protection ( input 320vac-48 hoursprotection,input 350vac-2 hours protection) (integral with light fixture). system lumen efficacy of 120 lm/watt ,thd 10 % , p.f. 0.95,cri >80 , life time of minimum 50000 burning hours with , 70% of intial lumen maintaned till life ends , cct 3000 k / 4000 k / 5700 k /6000 k/6500 k (as per ansi bin) as required., recessed mounting, minimum lumen output 4320 lm, providing & fixing of bee star rated copper wounded with class of insulation f, double ball bearing capacitor start, aluminium body & aluminium blade ceiling fan conforming to all the performance requirements laid down in is 374:2019 with down rod up to 30 cm with secondary support safety cable ( steel rope) , cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor and making connection testing etc. as required., 1200 mm sweep bee 1 star rated (service value >=4.0 to 4.5 ), providing & fixing of ventilating fans capacitor start, copper wounded, single phase with pvc impeller, abs body, automatic openable louver shutter in existing opening including making connection, testing etc. as required., 200 mm sweep minimum air delivery 450 cum / hour, providing & fixing of 450 mm sweep oscillating type wall mounting / pedestal type fans with three speed, on and off position, sintered iron bush oil impregnated, with metal front and back 120 or more ribs guard; three no. aluminium blades, minimum air delivery 100 cum. / minute , minimum service value 1.11 cum./min/watt, noise level should be = 75 db, power consumption = 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required., wall mounting type with adjustable vertical angle, supplying and laying fr pvc insulated & unsheathed flexible copper conductor of following nominal sizes with isi marked (is:694) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from copper, stranding in acc. to is:8130/iec 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation pvc type a/c/d , flame retardant as per is 10810-53, better amperage rat

corporations/Associations/Others

CTN :45321766 Due date: 15 Jun, 202615 Jun, 2026 45.73 Lacs
Tender For procurement of electrical spares and consumables for 220 kv and 33kv switch yard at khodri power station - 245 kv lightening arrester, discharge current 10ka, frequency 50 hz,pressure relief class 40 ka(rms), long duration discharge class 3, m.c.o.v. 56 kv, make: oblum electrical industries pvt. ltd. /cg power and industrial solution ltd. or eq make as approved by engineer in charge., 145 kv lightening arrester outdoor type ,suitable for 145kv system voltage , discharge current 10ka, freq. 50 hz, high current impulse (4/10 s) 100 ka, rated lightning impulse withstand voltage 1.2/50 s - 650 kvp, polymer based (single phase) make-oblum electrical industries pvt. ltd. /cg power and industrial solution ltd,/ htachi / siemens india ltd or eq make as approved by engineer in charge., auxiliary switch (stack) 5no + 5nc, 220v, dc, make: crompton, hitachi or eq make as approved by engineer in charge for 220kv cgl make sf6 circuit breaker., surge monitor/surge counter with leakage current meter suitable for 220 kv lightening arrestor , make: cg power and industrial solution ltd./ oblum electrical industries pvt. ltd., 33kv ct indoor type , 3 core, 15va each, ratio 650-350/1 a + 1a , class 0.2s(2 core metering) & 5p10 (protection), str: 25ka for 3 sec. make siemens, crompton, hitachi or eq make as approved by engineer in charge., 33kv ct indoor type, 3 core, 15va each, ratio 300-150/1 a + 1a , class 0.2s( 2 core metering) & (5p10 protection, str: 25ka, for 3 sec. make siemens, crompton, hitachi or eq make as approved by engineer in charge, control motor, type c21, 2.6 a, 230v ac/dc, o/p 0.3kw, sr. no: 042-901, m/y 03/08, 750/ min. make: kpt shirol or eq make as approved by engineer in charge for 33kv cgl make indoor type sf6 circuit breaker., auxiliary switch 7no+6nc (stack), 250 volt dc, make: crompton, hitachi or eq make as approved by engineer in charge for 33kv cgl make indoor type sf6 circuit breaker., auxiliary switch 8no+ 8nc, 220v, dc, (motor drive ). make: abb/ hitachi or eq make as approved by engineer in charge for 245 kv, abb make isolator., 220 v, dc, close or trip-1 coil ( part no. exin - 400834 - r9)make: abb/hitachi or eq make as approved by engineer in charge for 145kv, abb make sf6 breaker., rectifier 15 a, 220 v, ac (part no. 1hyn-450040p1 ) make: abb/ hitachi or eq make as approved by engineer in chargefor 245kv, abb make isolator, mcb (2 pole,3a, 220v, dc ), over current earth fault relay, mc61a-nx, cat no : mc61anx2200, make: l&t electrical & automation, or eq make as approved by engineer in charge for 33kv sf6 braeker., 33kv busbar support insulator (epoxy) . make: universal engg. corporation,star electrical engg. works or eq make as approved by engineer in charge.(as per sample), epoxy bushing/ fixed contact of "r","y" &"b" phase bottom side for 33kv cgl make panel (as per sample), epoxy bushing/ fixed contact "r","y" &"b" phase top side for 33kv cgl make panel (as per sample), ratech wheel of 33kv sf6 breaker, cgl make, flexible contact of 33kv sf6 breaker finger, cgl make (as per sample), silica gel blue crystal in mesh size of 15 mm to 35 mm duly packed in poly lined moisture proof m s drums/carton, heat shrinkable cable terminal kit for 3- 400mm ,33 kv xlpe cable for outdoor application (make 3m/raychem/ densons)., heat shrinkable cable terminal kit for 3- 400mm ,33 kv xlpe cable for indoor application (make 3m/raychem/ densons)., heat shrinkable cable terminal kit for 3- 185 mm 33 kv xlpe cable for indoor application (make 3m/raychem/ densons)., heat shrinkable cable terminal kit for 3- , 185 mm 33 kv xlpe cable for outdoor application (make 3m/raychem/ densons)., p g clamp deer/panther for 220 kv conductor, p g tclamp deer/ zebra, for 220 kv conductor, p g clamp deer/ trantulla for 220 kv conductor, p g clamp tarantula/ trantulla for 220 kv conductor, p g clamp deer/deer for 220 kv conductor, p g clamp made of aluminum-alloy suitable for zebra to trantulla conductor with 4 nos bolt - n

CTN :45348455 Due date: 06 Jun, 202606 Jun, 2026 NA
Tender For various works related to the protection system of 33/11 kv power sustation under business plan -2026-2027 item under electrical test division shahjahanpur district shahjahanpur

CTN :45322644 Due date: 01 Jun, 202601 Jun, 2026 8.70 Lacs
Tender For supply, installation, testing and commissioning of phase wire and street light and vairious electrical equipment needed for implementation of budget announcement 2025-26 - providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in, led street light fixture with minimum lumen output 5600 lm, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra )(d)wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap-offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be point to point (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)floor mounted panel sh

CTN :45319269 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For supply of ge (formerly alstom) make numerical (digital) idmt relay with 3 phase over current, earthfault protection with instantaneous tripping, negative sequence protection & broken conductor protection, complete with fault display and recording system & self-supervision facility & 4 nos. programmable led (multi colour) aux volt-24-230v, ac/dc, ct secondary 1a/5a (site selectable). part no. ekp154, motor management relay (draw-out type), with integrated electrical signature analysis for predicting thermal, electrical and mechanical faults like broken rotor bar, bearing failure foundation, looseness and misalignment having detachable color lcd display with in-build wi-fi, temperature, humidity and surge sensor. operating range 40°c to 85°c as per iec60068. ge (formerly alstom)

CTN :43568991 Due date: 20 Jun, 202620 Jun, 2026 NA
Tender For corrigendum : technical upgradation of unit #1 & #2 of 2x50 mw karbi langpi hydro electric project (klhep) of assam power generation corporation ltd. with state-of-the-art digital governor system, control system, microprocessor based electrical protection system and excitation system as per latest indian electric grid code.

Central Government/Public Sector

CTN :45335708 Due date: 29 May, 202629 May, 2026 NA
Tender For supply, installation, testing and commissioning of panel mounted microprocessor multi pump contoller with large graphical display and integrated in a single body or as separate componentswith pressure sensor transmitter (one dedicated to each pump), diodes to indicate pump ready, pump running and fault and capable to communicate with other controllers. system should be capable to compensate for frictional losses at lower flows. system should be equipped with dry running protection. indication of all type of faults / on-off status / electrical parameters shall be available on panel (1 w+1 s) required for 25 hp end suction pump as per bq attached. one set qty consists of 2 units [ warranty period: 12 months after the date of delivery ] ]

State Government

CTN :45288602 Due date: 08 Jun, 202608 Jun, 2026 36.52 Crore
Tender For survey investigation, design, supply, installation, testing and commissioning of tank filling scheme consisting of construction of intake channel, forebay, jack well cum pump house, power supply including terminal bay, transmission line, electrical substation, rising main, distribution network, delivery chamber, gravity main network, various types of valves, receiving chambers, staff quarters, surge protection system for filling of 22 tanks in kambadal hosur and surrounding villages by lifting 0.19 tmc of water from bhadra river near gonibeedu village of bhadravathi taluk, shimoga district including operation and maintenance for a period of 5 years after successful completion of work for kambadal hosur tank filling scheme on turn-key basis

corporations/Associations/Others

CTN :45300161 Due date: 02 Jun, 202602 Jun, 2026 4.25 Lacs
Tender For supply and fixing of high mast light material at mia alwar - providing & fixing of ik08 ip-66 protected high power led flood light system with single piece pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on led to achieve various beam angles, of high power led of 3 to 5 watt each . integrated potted driver as a unique bis r number having efficiency more than 85 % and in compliance to bis certified and trade mark certificate. the system level luminaire efficacy >=125 lm/ wt. led driver input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety .power factor >0.95 , thd(i) 10% , driver current =750ma. driver should be phase to phase protection of 440 v for 4 hrs. electrical connector , surge protection min >=4kv internal and 10kv external but inside driver compartment, system life of 50000 burning hours with 70% of initial lumens maintained, cri>70 and cct 5700k 355k. manufactures word mark/name engraved/embossing/screen printing on die cast housing to allow traceability/authenticity. fixture shall be is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate/ report with liable warranty of product/accessories from oem shall be submitted. all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr ., high power led flood light minimum lumen output 14800 lm
 Loading, Please wait...

Connect us via What's Up