Web Analytics Made Easy - StatCounter

So2 Analyzer Tenders

Get complete information related to latest So2 Analyzer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic So2 Analyzer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding So2 Analyzer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government / Public Sector

CTN :40825578 Due date: 21 Aug, 202521 Aug, 2025 NA
Tender For corrigendum : supply of so2 analyzer , nox analyzer for online stack monitoring , out of stack dilution probe , zero air generator , umbilical cord

CTN :41426226 Due date: 03 Sep, 202503 Sep, 2025 NA
Tender For supply of 60.00. 05.219. 9 ccu regen oxygen analyzer system , installation and commissioning of o2 ana

State Government

CTN :40985783 Due date: 25 Aug, 202525 Aug, 2025 1.50 Crore
Tender For corrigendum : purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-a

Central Government And Public Sector

CTN :41345509 Due date: 25 Aug, 202525 Aug, 2025 1.62 Crore
Tender For procurement of enhanced trace level so2 analyzer

CTN :41314740 Due date: 14 Aug, 202514 Aug, 2025 NA
Tender For supply of supply of adage gas analyser - analyser lcd module adage 28602 28602 , analyser o2 sensor pa adage u23 u23 , analyser ceramic filt adage 28903 28903 , analyser spr flow meter adage 18709 , analyser flow meter adag 18709 18709 , analyser spr glass wo adage 18106 , analyser ring heater adage 18524 , glass wool gasket for ceramic filter 50 mm dia , o ring size 68mm odx4mmthick condensate monitor , mmi 7 display with i o card support , cartridge filter , chopper 2 ir channels ultramat 23 , co detector set co receiver analyzer chamber 1mm , detector co2 1000 ppm ultramat 23 , measuring head oxymat , o2 sensor oxymat 61 including sample cell , motherboard for oxymat , front panel without keyboard calomat 6e , motherboard for ultramat 23 , sensor for calomat 6 , analyser gas analyser adage 28604 ultr , analyser gas analyser adage 28605 oxym , analyser gas analyser adag 28606 calom , inst gen item pvdf valve 3 2 adage ) /bid number : gem/2025/b/6531037 * /dated: 04-08-2025 & & / bid document 1 / 23

CTN :41286691 Due date: 21 Aug, 202521 Aug, 2025 NA
Tender For supply, installation and commissioning of gas analyzer with co2 and o2 probe for the rgm funded project "implementation of ivf technology under rgm at cvsc, aau, khanapara & establishment of professional training institute at lcvsc, aau, lakhimpur

Central Government/Public Sector

CTN :41259210 Due date: 13 Aug, 202513 Aug, 2025 NA
Tender For procurement of spares for generon make igg installed at bpb platform- filter element 0.01micron ( tag no: maj*, pressure differential transmitter rang*, pressure transmitter (tag no: 1/2 pt-81*, temperature transmitter tt-101a/b, tt-1*, rtd with thermowell, flow transmitter, flow transmitter, solenoid valves, prv103,model:hf1201sk3px8b, compactlogix 5370 l3 controller, 24vdc sink/source input, 16 channel 24vdc digital output card, 8 channel analog current/voltage input *, aanlog output card, relay, dpdt: 24v ,8a,atex-zone1, isolator barrier,single channel a/1,atex, cntrlr,power,ss,46a,3p,277-600v,4-20ma, power supply ,24vdc/10 a,1ph,atex, ft vortex flowmeter,0.500,flg,300#,atex, valve , ctrl,0.750,150#,rf,316ss,w/p,c*, positioner electro-pneumatic, solenoid valve , sn,3w/2p,n/c,24v,316ss*, rtd-tw,0,500,npt,u=3,316ss,atex, moisture analyser, oxygen analyzer, o2 sensor type 4xip66 (fuel,cell,ox-3,0*, valve with actuator ,, valve limit switch, valve top,model dxp*, valve with actuator ,model: rf1rgggfl, *, valveprv,).250/5 to 35 psig,316s,w.gaug*, actuator, regulator, valve,prv,0.250,/0 to 150 ps*

State Government

CTN :41235843 Due date: 20 Aug, 202520 Aug, 2025 7.10 Lacs
Tender For supply of yokogawa make o2 analyzer detector

State Government

CTN :41235905 Due date: 25 Aug, 202525 Aug, 2025 3.14 Lacs
Tender For supply of testo340 spares for chem lab gtps. - o2 replacement sensor for testo 340 (0 to 25 vol percentage ) resolution 0.01 vol percentage, co sensor (h2 comp) (spare of testo make portable flue gas analyzer model no 340) replacement sensor range 0 to 10000 ppm. item model code no 03930100, no sensor for testo make flue gas analyzer model no 340. replacement sensor range 0 to 3000 ppm. item model code no 03930150., so2 sensor (spare for testo make flue gas analyzer model no 340). replacement sensor range 0 to 5000 ppm. item model code no 03930250., rechargable battery li ion for testo 340 flue gas analyzer, special sampling hose for ind. probe for testo make flue gas analyzer model no 340., thermocouple 1.2 meter nicr-ni for testo 340 flue gas analyzer., shock protection cover for testo make flue gas analyzer model no 340., o ring for testo, o2 replacement sensor for testo 340 (0 to 25 vol percentage ) resolution 0.01 vol percentage, co sensor (h2 comp) (spare of testo make portable flue gas analyzer model no 340) replacement sensor range 0 to 10000 ppm. item model code no 03930100, no sensor for testo make flue gas analyzer model no 340. replacement sensor range 0 to 3000 ppm. item model code no 03930150., so2 sensor (spare for testo make flue gas analyzer model no 340). replacement sensor range 0 to 5000 ppm. item model code no 03930250., rechargable battery li ion for testo 340 flue gas analyzer, special sampling hose for ind. probe for testo make flue gas analyzer model no 340., thermocouple 1.2 meter nicr-ni for testo 340 flue gas analyzer., shock protection cover for testo make flue gas analyzer model no 340., o ring for testo
 Loading, Please wait...

Connect us via What's Up