Web Analytics Made Easy - StatCounter

Soaking Pit Repair Tenders

Get complete information related to latest Soaking Pit Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Soaking Pit Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Soaking Pit Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45352757 Due date: 08 Jun, 202608 Jun, 2026 11.41 Lacs
Tender For street light accessories and phase wire work in losal area - work, supplying and drawing of xlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255/1995 and is 398 (pt-4)/ 1994 and as per discom specs. on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a"attached with this bsr ., 1 x 25 sq. mm. + 1x25 sq. mm. (insulated), supply and fixing of following lt supporting accessories with nut bolt & clamps made out as per standard discoms specifications with two coats of red oxide and two coats of aluminium paint etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsr, suspension clamp with eye hook & pole clamp, dead end clamp with eye hook & pole clamp, p & fixing powder coated crca sheet enclosures on existing angle iron frame by means of nuts and bolts and making holes , din rail etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr, 2.0 mm thick, providing & fixing of ac operated heavy duty 230 /440 volt power contactor as per pwd specification for electrical works, isi marked is/iec 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, din rail mounting type including making connections, testing etc. as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr ., 4 pole power contactors with following ac 1 rating 63 amp, providing & fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16-20 amperes including making connection, programming conforming to iec 60730-1 and 60730-2-7 etc. as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr ., one day & week reserve (analog type ), sitc of 3 /4 pole current limiting moulded case circuit breaker (mccb) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 v, 50 hz; o/l & s/c settings , conforming to is/iec 60947 p -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage 690 v. provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.oem shall have submit nabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in-charge. for additional technical parameters of product/ work refer annexure a attached with this bsr, 4 pole mccb with thermal magnetic release up to 100 amp , 10 ka, fixed o/l & fixed s/c setting, pipe earthing as per is:3043- 1987 with 3.0 mtr. long, 40 mm dia. b class g.i. pipe is: 1239 (part-1) 2004, equivalent to bs : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and heavy duty weather proof poly-propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350mm. and height 250 to 300 mm. and embodying the pipe compl

Central Government/Public Sector

CTN :45277567 Due date: 29 May, 202629 May, 2026 NA
Tender For name of work testing of 33 kv 6.6 kv cts by primary injection set,secondery injection, hv tast, for relays effectiveness testing ,o/h line ,earth pit , cable and also issuing test certificate for record at 33 kv sudamdih shaft mine substation under asp colliery

CTN :45138827 Due date: 28 May, 202628 May, 2026 NA
Tender For supply of s and f of ring main system for wss - supplying laying jointing commissioning and testing 100mm bore centrifugally cast spun ductile iron pressure pipe with spigot and socketed ends class k7 confirming to is 8329 or 2000 as per atc , supplying laying jointing commissioning and testing 150mm bore centrifugally cast spun ductile iron pressure pipe with spigot and socketed ends class k7 confirming to is 8329 or 2000 as per atc , supply and fix valve reflux with by pass arrangement 100mm 4 inches dia , supply and fix foot valve confirming to is 4038 100mm 4 inches dia , supply and fix valve sluice flanged of class 1 point 6pn 100mm 4 inches dia , supply and fix valves sluice flanged of class 1 point 6 pn 150mm 6 inches dia , supplying installing testing and comissioning of centrifugal pump electric driven capacity not less than 25 lps discharge at 60 metre head in load as per atc , supply laying testing cable xlpe insulated screened pvc bedded galvanized steel strip wire armd electric powercable hd 1100v grade stranded aluminium conductor size 70 sqmm 3 point 5 core , supply laying testing cable xlpe insulated screened pvc bedded galvanized steel strip wire armd electric powercable heavyduty 1100v grade stranded aluminium conductor size 10 sqmm 4 core , supplying installing testing and commissioning of outdoor type factory made crca sheet thickness 3 point 15mm platform mounted lt panel board to accommodate as per atc , supplying installing testing and commissioning of indoor type factory made crca sheet thickness 2mm platform mounted lt panel board to accommodate as per atc , supply install test commission centrifugal openwell submersible pump cap 10hp singlephase discharge range 740 to 200lpm head range 35 to 54m suction x discharge pipe dia 65x50mm as per atc , supply and fix cast iron air valves with two air outlets 80mm dia bore and fixing up in ) /bid number : gem/2026/b/7514655 * /dated: 08-05-2026 & & / bid document 1 / 21 & & ' ' /item category cast iron water supply mains , excavation in tranches not exc 1 point 5m wide n exc 1 point 5m depth over exc 10sqm on plan and n exc 1 point 5m in depth for foundations shafts wells cesspite mainholes pier holes as per atc , returning filling in including spreading laveling watering and well ramming in layers n exc 25cm in soft or loose soil complete all as specified and directed by engr in charge , removal of excavated soil material to a distance not exc 50m or depositing where directed at a level not exc 1 point 50 metre above th staring point complete all as specified as per atc , boring of hole under road pavement hardstanding by trenchless technology using ultra sounding technique nec machine incl hdpe pipe 150mm dia suitable for 0 point 4mpa working pressure , cutting existing ci or di pipe line of 150mm and inserting tee of size 150 x 150 x 150mm for taping complete all as specified and directed note tee 150 x 150 x 150mm paid separetly in di special , cutting existing ci or di pipe line of 150mm and inserting tee of size 150 x 150 x 100mm for taping complete all as specified and directed note tee 150 x 150 x 100mm paid separetly in di special , di or ci special such as tee bend collar tail piece and other fitting as required , earthing of poles and other machinery or equipment using 4mm gi wire as earthing lead and ms galvanized plate of size 60cm x 60cm x 6mm as earth electrode , demolition and diasmanttling of concrete in ground floor and pavings n exc 15cm thickness , m and l of cement concrete b 2 1 colon 2 colon 4 40mm graded aggregate 100mm thickness , m and l for contruction of brick masonry valve pit in repair of inter size 90x90x90cm incl nec exc earth work in soft or loose soil brick work plastering white wash pcc coping ms frame as per atc , m and l for contruction of brick masonry valve pit in repair of inter size 120x120x90cm incl nec exc earth work in soft or loose soil brick work plastering white wash pcc coping ms frame as per atc

CTN :44990329 Due date: 08 May, 202608 May, 2026 22.88 Lacs
Tender For corrigendum : strengthening the headgear structure as per the structure stability test report recommendations to comply with dgms violations through fabrication work using different sizes of ms material for safe and smooth winding operations at pit no. 2, pit no.
 Loading, Please wait...

Connect us via What's Up