Tender For procurement and installation of different instruments for instrumentation of earth dam and spillway in deo irrigation project for the year 2025. - supply of fiberglass reinforced plastic (frp) make universal enterprises an improved venturi plate conformed to is: 9108 for accurate measurement of water flowing through channels comprising of masonry construction provided with pre-fabricated glass fiber lining on both sides, a side chamber provided in one side masonry wall of the said flume on the upstream side, a pipe provided at the bottom of the chamber connecting the said chamber with the water flowing through the notch, a float means provided in the said chamber, enabling recording the rising or falling level of water in the said chamber such as a scale provided in the said chamber, moulded engraved gauge marking in lit/sec and also in centimeter including moulded and engraved discharge table, capacity marking, flow direction, m.s pipe stiffeners, hold fasts, sand treatment on the backside of plate but excluding gst as per the instruction of engineer-in-charge etc. complete, inside spillway foundation gallery - 15 lit./sec. v-notch, seepage drain - 90 lit./sec. v-notch, calibration marks:- supply of polymers composites improved calibration marks make universal enterprises with contact molding process, both side finish, m.s. strip embedded inside, engraved and molded marking for bands and figures covered with radium and covered with two coats of polyurethane for surface protection with marking in reduced levels, sill, fsl, frl, mwl but excluding gst as per the instruction of engineer-in-charge etc. complete, supply vw up-lift pressure meter provision for connected to das make : aimil ltd. uplift pressure meters are used for measuring and recording of uplift pressures acting in foundations of concrete/masonry dams. vibrating wire type uplift pressure meter : range: 0.2 mpa to 5.0 mpa./7ksc accuracy: 0.5 -1 % fs. temp limit: - 10 to 70 deg c. coil resistance: 140 - 160 ohm thermistor: ysi-44005 or equivalent. material: stainless steel cable: 1m, 4-core borehole for uplift pressure meter at foundation gallery (inside spillway) should be straight from foundation level and clear. proposed location : inside spillway foundation gallery in overflow section: 7 no. non overflow section: 2 no. purpose: uplift water pressure measurement. (but excluding gst), supply automatic seepage measuring system make : aimil ltd / sysgeo italy or equivalent vibrating wire water leakage measuring systems are used for measuring water leakage and flow in dam galleries by installing v notch weir coupled with vibrating wire sensor for remote monitoring of water leakage. sensor type: sensor : vibrating wire precision water level sensor range: 300mm resolution: 0.025%fs material : stainless steel excitation : sweep or pluck assembly: v.w. type sensors enclosed in an environmental proof fibre glass box. splicing kit & adhesive required accessories. proposed location : inside spillway foundation gallery: 1 no. toe drain: 1 no. (drainage outlet) purpose: seepage water measurement in liter per second (but excluding gst), supply data logger or data acquisition system aimil make dt85g with cem20 or ace s korea analog channels 16 analog input channels each channel is independent and supports: one isolated 3-wire or 4-wire input, or two isolated 2-wire inputs, or three common referenced 2-wire inputs. expansion requires optional cem20 sampling integrates over 50/60hz line period for accuracy and noise rejection maximum sample speed: 40hz effective resolution: 18 bits linearity: 0.01% common mode rejection: >90db line series mode rejection: >35db vibrating wire frequency range: 500 to 5khz coil resistance: 50 to 200 stimulation method: single pulse pluc digital channels 8 bi-directional channels input type: 8 logic level (max 20/30v) output type: 4 with open drain fet(max: 30v, 100ma) 4 with logic output alarms power supply , sim card will be in your scope. propo
Tender For supply of cardiology implants and equipmets, high pressure lineavailable in 150cm and 200cm, made of branded pvc, very flexibleand pressure should hold up to 1200psi with leur lock on one side and collerfillting on other side., radial introducer needle 18g, 32mm length, inner diameter 1.3mm, braided long sheath*atraumatic tip for carotid & distal procedures*hemostatic valves to prevent back leak and air aspiration.with tbv detachable valve for thrombus management *gold coil marker for distal visibility, distal hydrophilic coating *ptfe coating seamless device transition* available in diameter 6,7,8 f and length 45cm,65cm & 90cm.* with suture eye for securing sheath.nylon out layer with stainless steel coil * with internal side port with attached 3 way stopcock., radial artery haemostasis device- (t.r. band) consists of two balloons specially designed for spot compression of the radial puncture site. must have belt magic tape for fast application. must have curved support plate. must have green positioning marker. must be available in 2 sizes 24cm and 29cm usfda/pmda approved, hydrophilic guidewire with mcoat technology tapered tip, (regular length) single nitinol core alloy, tungsten-infused polyurethane jacket hydrophilic polymer coat.one piece construction & radiopaque polyurethane jacket. must be available in standard and stiff. must be available in .032, .038, .025, .018 diameter and 150 cm, 180 cm length - straight / angled / 1.5 mm j shape usfda approved, hydrophilic guidewire with mcoat technology tapered tip, (exchange length) single nitinol core alloy, tungsten-infused polyurethane jacket hydrophilic polymer coat.one piece construction & radiopaque polyurethane jacket. must be available in standard and stiff. must be available in .032,.035, .038, .025, .018 diameter and 260 cm length - straight / angled / 1.5 mm j shape usfda approved, hydrophilic guidewire with mcoat technology tapered tip, (regular length) single nitinol core alloy, tungsten-infused polyurethane jacket hydrophilic polymer coat.one piece construction & radiopaque polyurethane jacket. must be available in standard and stiff. must be available in .032, .038, .025, .018 diameter and 150 cm, 180 cm length - straight / angled / 1.5 mm j shape pmda approved, hydrophilic guidewire with mcoat technology tapered tip, (exchange length) single nitinol core alloy, tungsten-infused polyurethane jacket hydrophilic polymer coat.one piece construction & radiopaque polyurethane jacket. must be available in standard and stiff. must be available in .032,.035, .038, .025, .018 diameter and 260 cm length - straight / angled / 1.5 mm j shape pmda approved, baby j wire (180 cm) with radius of 1.5mm j tip, (regular length) must have tungsten-infused polyurethane jacket. baby j curve must have radius of 1.5 mm. super elastic nitinol alloy, m coat hydrophilic coat, one piece construction for 1:1 torque & radiopaque polyurethane jacket. usfda/pmda approved, baby j wire (300 cm) with radius of 1.5mm j tip, (exchange length) must have tungsten-infused polyurethane jacket. baby j curve must have radius of 1.5 mm. super elastic nitinol alloy, m coat hydrophilic coat, one piece construction for 1:1 torque & radiopaque polyurethane jacket. usfda/pmda approved, guide wire hydrophillic coated 0.0 32x150 cm polyurathane jacket.glider torque devices. super elastic nitinol core. eurepean ce, special slender sheath (gss) for trans radial rootmust have unique thin wall technology reducing the outer diameter by 1 fr size whilst maintaining the one size lager inner diameter. must have 7fr sheath with outer diameter of 2.8mm, 6fr with od of 2.46 mm & 5fr with od of 2.13mm. hydrophilic m coating with 20/21g surflash needle and tif tip technology which provide optimal tapering design.usfda/pmda approved, radial sheath with puncture needlestandard length includesurflash 20g*2 entry needle (plastic iv catheter) and 0.025 mini plastic guidewire.radial introducer
Tender For supply of supply of 3d printed reinforced concrete panels , supply of box sections of size 100x100x5mm , supply of 16mm tmt bars , pcc solid block , stone patti slab each of size 900x300x50mm , paver block m2 0 grade , flexible polyurethane foams sealant 750ml , exterior weather proof paint , ms loop hole of size 900x400mm , ms door of size 900x1850mm , sand bag 18inch x 34inch , pbs roll 20m x 1m , bitumen primer , opc 53 grade cement , well graded sand , all in one aggregate , 0 point 5 mm thick metal deck ppgi sheets , 12 mm tmt rebar fe 500 grade , binding wire , steel cutting blade 4 inch dia , distemper oil emulsion , w2 panel , clay bricks
Tender For supply of two component polyurethane based matt anti graffiti paint (top coat) to mdts-118 - rev.01, table - 5 with matt finish gloss value 10-12 at 45 degree of colour shade ral ds-9000 as per rcf letter md 22151 dtd.29-04-2021. keeping properties: not less than one year
Tender For 01(2025-26) item no. 01 cardiothoracic equipments and implants - titanium ligaclips small with small diamond shape pyramidal heads, similar to needle holder inserts, ensuring a firm multi-directional atraumatic grip. interlocking atraumatic teeth designed for non-slip closure on the vessels. triangular shape of the titanium wire for the precision of the positioning of the clip into the jaws of the applier. should be us fda approved., titanium ligaclips medium with small diamond shape pyramidal heads, similar to needle holder inserts, ensuring a firm multi-directional atraumatic grip. interlocking atraumatic teeth designed for non-slip closure on the vessels. triangular shape of the titanium wire for the precision of the positioning of the clip into the jaws of the applier. should be us fda approved., titanium ligaclips large with small diamond shape pyramidal heads, similar to needle holder inserts, ensuring a firm multi-directional atraumatic grip. interlocking atraumatic teeth designed for non-slip closure on the vessels. triangular shape of the titanium wire for the precision of the positioning of the clip into the jaws of the applier. should be us fda approved., proximal aortic anastomosis device. it should provide stable blood field. it allows for up to three anastomosis from one insertion. size 3.5mm/4.0mm/4.5mm, membrane oxygenator (plasma resistant) with integrated arterial filter. should have surface area with surface area of 1.4 m2. it should have radial blood flows design to give efficient gas transfer. it should have quick priming inlet and vacuum assisted venous drainage. oxygenator should have self-venting facility. integrated arterial filter should be polyester/polycarbonate/equivalent material. integrated arterial filter pore size should be less than 40 micron with the surface area of around 60-80cm2. priming volume of around of less than 285ml visible path top to bottom should have maximum flow for large body surface area patient ranging from 0.5 to 6 l/m. should have phosphoryl choline (pc) coating like phisio. should be able to operate at venous reservoir level of minimum 150 ml. oxygenator reservoir should have polycarbonate/polyester/equivalent screen type venous filter with pore size less than 50 micron. should be us fda approved. should be supplied with appropriate stand., uw solution for organ transplant use., dacron graft knitted bioseal grafts diameter 6mm to 8mm length 30 cm, dacron grafts knitted bioseal diameter 6mm to 8mm length 60 cm, dacron grafts woven bioseal diameter 20mm to 32mm length 30 cm, aortobifemoral bioseal graft dacron sizes - 6x12x45 / 7x14x45 / 8x16x45, coronary osteal cannula10fr/12fr/14fr, intra cardiac sump20fr/12fr, eptfe grafts plain straight diameter 6mm/7mm/8mm length 20 cm us fda approved, eptfe grafts plain straight diameter 6mm/7mm/8mm length 40 cm us fda approved, eptfe grafts plain straight diameter 6mm/7mm/8mm length 50 cm us fda approved, eptfe grafts plain straight diameter 6mm/7mm/8mm length 60 cm us fda approved, eptfe grafts plain straight diameter 6mm/7mm/8mm length 70 cm us fda approved, eptfe grafts plain straight diameter 6mm/7mm/8mm length 100 cm us fda approved, eptfe grafts plain straight diameter 6mm/7mm/8mm length 75 cm us fda approved, eptfe grafts ring reinforced diameter 6mm/7mm/8mm length 20 cm us fda approved, eptfe grafts ring reinforced diameter 6mm/7mm/8mm length 40 cm us fda approved, eptfe grafts ring reinforced diameter 6mm/7mm/8mm length 50 cm us fda approved, eptfe grafts ring reinforced diameter 6mm/7mm/8mm length 60 cm us fda approved, eptfe grafts ring reinforced diameter 6mm/7mm/8mm length 70 cm us fda approved, eptfe grafts ring reinforced diameter 6mm/7mm/8mm length 75 cm us fda approved, eptfe grafts ring reinforced diameter 6mm/7mm/8mm length 100 cm us fda approved, iodine impregnated incision drape, size 55cm x 45 cm (ahesive area). should be gamma sterilize. should be polyurethane adhesive coated surgical film with povidone iodine.