Get complete information related to latest Soil Salinity Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Soil Salinity Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Soil Salinity Meter Tenders.
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - stirrer- the stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. the stirring speed should be 50-1500 rpm or better. the stirrer should be operational up to a temperature range of 300oc with an accuracy of 1.0oc and ip 42 protection class. the input power should be 600 w or above. the stirrer should be supplied with hemispheric bowl (100 ml= 1 no; 250 ml= 1 no) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks.warranty must be one year., electronic balance- the electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. the system should have automatic internal calibration with touch screen display. the system should have internal database capacity of 2500 or more with multiuser password protection feature. warranty must be one year., vaccum pump - the pump should be operational at a maximum power of 65 w or more with a max. vaccum of 99 mbar or more. the pump should be fitted withvacuum and filter cartridge., hot air oven- the inner chamber should be made of stainlesssteel and the outer chamber should be m.s powdercoated. the maximum capacity of the oven shouldbe 100 ml or more. the operational temperatureshould be between ambient to 250oc or more witha temperature accuracy of 1o c. pid based digitaltemperature control., double distillation unit- the unit should be pyrogen free with a distillation water output capacity of 1.5 l/h. the minimum cooling water requirement should be 1lt/min. auto-power cut facility in case of halted supply of water., circulating oil bath- the oil bath should be made up of stainless steel with 4 digit 7 segment led display for temperature and time. the bath should have s.s perforated tray for holding flasks. the bath should have a capacity to accommodate flask of 1l. the working temperature range should be +5 to 240oc (0.1oc increment) with a temperature stability of 1oc, water bath- the water bath should have a capacity of 20 l within built water level sensor. the bath should be made up of stainless steel and supplied with 8 concentric rings. the bath should have digital temperature control with pt100 sensor. the system should have stirring capability with ptfe magnetic bars., ph/ condutivity meter - operational between a ph range of -2 to 16.00 with a resolution of 0.01 ph and an accuracy of 0.02 ph. 5 points calibration. the ec range shouldbe in between 0.00 to 29.99 s/cm, uv cabinet- operational at two uv wavelengths (254 and 365 nm). the cabinet should also be equipped with one visible light. the external body should be coated with ms powder/epoxy., flame photometer- application: the flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. these metals include na+, k+, ca2+, ba2+ and li2+.specification requirementmeasuring range na+: 0 to 99.9 ppm k+:0 to 99.9 ppm ca 2+ :0-99.9 ppmli 2+: 0 to 99.99 ppmsensitivity na+= 0.1 ppmk+ = 0.1 ppmspecificity less than 0.5% interference when concentrations are equal to test sample concentrationsgas control-adjustable with knobsignition system-auto ignition systemflame failure-auto detectiongas cut off-automaticreproducibility-less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm na set as maximum standardlinearity-less than 1%display led, 12.5 mm (1/2")fuel supply-high-grade propane/butane mixture regulated at approximately30 psiair supply-6 l/min at 12 psi; oil and moisture freerecorder-output 0.05 to 5 v (switchable)operating manuals, service manuals, other manuals should provide user, technical and maintenance manuals in english language list of equipment and procedures required
Tender For corrigendum : supply of reducibility index/reduction degradation/thermal degradation index setup - scada-plc based ri-rdi apparatus, scada-plc control panet, reaction vessel (retort), vertical electric furnace, automatic lifting system, thyristor power drive, digital mass flow meters, microprocessor-based pid controller, ss-316 gas mixing chamber, digital rpm controlled tumbler (for rdi), co₂ gas pre-heater, digital co burning system, retort cooling chamber, warranty
Tender For corrigendum : repair and maint of ci gi di pipe line pumping set sluice foot valve nrv valve chamber, lt control panel etc inc cleanning of oh tanks and ug sumps in ncat technical area residential area and bhingar pump house at vrde ahmednagar 06
Tender For supply of tripping and closing coil assly pn ald6064 , heavy duty numerical relay with 3 oc and 1 ef pn ald6656 , breaking chamber insulator with internal pn ald6023 , supporting insulator with accessories pn ald6042 , master trip realy pn ald6634 , mechanism with spring charge motor pn ald6010 , anti pumping relay pn ald6034 , oil temperature alarm_trip relay pn al80617 , power pack unit for emergency backuppn ald6644 , closing coil assy pn al37024 , tripping coil assy pn al37025 , spring charging motor pn al37021 , control cable connecting set pn ald6080 , winding temperature alarm_ trip relay pn al56639