Web Analytics Made Easy - StatCounter

Solar Mast Light Tenders

Get complete information related to latest Solar Mast Light Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Solar Mast Light Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Solar Mast Light Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :43802118 Due date: 10 Feb, 202610 Feb, 2026 NA
Tender For supply of elecric bells and accessories as per is 2268 (q3) , modular piano type domestic electrical switches as per is 3854 (q3) , led bulkhead light (q3) , led tube light (retrofit type) (q2) , led luminaire for high bay lighting (q3) , pvc copper cable single core and multi core circular sheathed cord with flexible conductor (v2) as per is 694 (q2) , piano type non modular electrical switch socket combination as per is 3854 and is 1293 (q3) , piano type modular domestic fan regulator as per is 11037 (q3) , mcb , crca mccb metal powder coated box , outdoor type street light cable junction box , gang box , 10w bollard , foot light 03w , surface mounted luminaire , mild steel step pole, 3.50m long suitable for led post top lanterns , 60w pole top , pendent lamp holder , anglar lamp holder , batten lamp holder , led garden light pole base , spike light , spot light , ac box , crca juction box , mccb box , neutral switch fuse unit , contactor , lightning arrester , lightning strike counter , metal clad plug top , metal clad socket , on-load changeover switch , porcelain pin insulator , preventer relay , main switch , transformer oil type ii , lead wool , steel wool ) /bid number : gem/2026/b/7167047 * /dated: 31-01-2026 & & / bid document 1 / 66

CTN :43798404 Due date: 09 Feb, 202609 Feb, 2026 18.49 Lacs
Tender For maintenance of electrical and mechanical installation at testing station for the department of explosives at gondkhairy for the year 2025-26subwork/packages:replacement of oh line supply, installation, testing and commissioning of led bollard light repairing of 2 nos led sign borads and 100ah smf battery etc for the year 2025-26

Central Government/Public Sector

CTN :43498269 Due date: 05 Feb, 202605 Feb, 2026 20.00 Lacs
Tender For corrigendum : repair maintenance of various type of street light, bollard light fittings at maintenance command communication flight, 22 provost and security, aksc vayusena nagar, nagpur

State Government

CTN :43673931 Due date: 02 Feb, 202602 Feb, 2026 11.81 Lacs
Tender For corrigendum : a&a to bollard light at govt. residential bunglow sector-19&20,gandhinagar [for one year]

Central Government/Public Sector

CTN :43574276 Due date: 04 Feb, 202604 Feb, 2026 45.00 Lacs
Tender For repair maintenance of garden light fitting fixture bollard light gate light at officers mess esd fol depot stn road moude road airport road office complex under ge north delhi cantt 10

CTN :43690456 Due date: 06 Feb, 202606 Feb, 2026 19.80 Lacs
Tender For s/i/t/c of bollard light to be provided on s paths between medical college to auditorium and infront of nursing college and various other locations at aiims, rishikesh

CTN :43713871 Due date: 31 Jan, 202631 Jan, 2026 26.15 Lacs
Tender For maintenance of electrical installation and fans maintenance of electrical appliances hmps bungalows under north avenue, new delhi.sub head- replacement of damaged / faulty bollard lights at various bungalows.subwork/packages:replacement of damaged/ faulty bollard light at various bungalows.

Central Government/Public Sector

CTN :43711355 Due date: 14 Feb, 202614 Feb, 2026 NA
Tender For supply of electrical maintainance item d d -pin multiplug socket with 2 output , batten holder , porcelain holder , bell ding dong , water pump for desert cooler , 4 way sp single door distribution board in metal , fiber and plastic body exhaust fan with dimensions 200mm speed , fan clamp , 8 fan sheet , pvc round sheet , 6 amp 2 way gang box 1switch 1socket , 16 amp 2 way gang box 1switch 1socket , 6 amp 1 way gang box 1switct , 6 amp 1 way gang box 1 socket , bearing 6201 , bearing 6202 , 1.5 pvc gitties , 1,2 4 head black screw , 1 4 head black screw , 1,2 machine screw , 3,4 machine screw , 1.5 machine screw , 2 machine screw , 2.5 machine screw , pvc tape 7.5 meter , 3by4 pvc conduit pipe make like - astral,diplast,polypack , 3by4 pvc bend make like - astral,diplast,polypack , 3by4 pvc junction box make like - astral,diplast,polypack , 1 pvc conduit pipe make like - astral,diplast,polypack , 1 pvc bend make like - astral,diplast,polypack , 1 pvc junction box make like - astral,diplast,polypack , 1 gi clamp , 1 pvc tee , 40 mm pvc conduit pipe make like - astral,diplast,polypack , 40 mm pvc bend make like - astral,diplast,polypack , 40 mm pvc junction box make like - astral,diplast,polypack , 2 sq.ft.4 sq ft. bakelight sheet , 6 sq mm ring type copper thimble , 6 sq mm pin type copper thimble , 16 sq mm ring type aluminum thimble , 25 sq mm ring type aluminum thimble , 400 sq mm ring type aluminum thimble , 240 sq mm inline type aluminum thimble , 400 sq mm inline type aluminum thimble , 1 flexible pipe , pcb board of 1200mm,1400 mm ceiling fan make super fan , bearing 6001 , bearing 6205 , 2.5 mfd capacitor , 3.15 mfd capacitor , 4.0 mfd capacitor , 4.0 mfd capacitor oil type , outdoor ac aluminium grill jali size-24inch24inch , 3,4 self screw , 12-18 watt led bollard pathway,garden light-warm white , 2.0 core x 10 sq mm pvc aluminium cable , 2 core x 16 sq mm pvc aluminium armoured cable , 4 core x 16 sq mm pvc aluminium armoured cable , 4 core x 16 sq mm pvc copper cable , 7 into 5 wooden box , 8into5 wooden box , 10into5 wooden box , 7into5 bakelite sheet , 8into5 bakelite sheet , 10into5 bakelite sheet , gulmekh iron , ultra fast rechargeable batteries charger for aa and aaa , 1 phase electric energy lcd digital meter 0-40 amp capacity , 3 phase electric energy meter with capacity 10- 60 amp , single phase digital engery meter with kw , 3 phase direct measuring energy meter , supply of 3-phase, 3 wire, ac voltmeter with voltage , supply of 3-phase, 3 wire, ac ampere meter , 3 phase 4 wire ,5amp. voltage range 230 , current transformer ratio 300 , digital mega ohmmeter, insulation resistance tester , digital clamp meter ,with range of 40a,600a ac , crc spray, 2-26 grade of 500 ml. , electrical insulation spray of 400 ml in red composition , aluminium oxide sand paper 80mm width , thinner for cleanig electrical conductors , bell switch one way piano type make- havells,anchor, vinay , single phase meter pvc transparent box , three phase meter pvc transparent box , mastic tape , 63 amp sliding terminal contact block for 1.5-10 sq mm in polyamide material , desert cooler water pump , 16 kg copper winding demolition hammer with 1600 watts power,220volt inpu , 150 watt hot glue gun with 20 glue stick , set of screw driver with minimum 6 screw driver head , tool kit with electrical impact drill with of 3000rpm , 100 watt rechargeable led flood lights , multipurpose pu foam of 700- 800 ml capacity , rotary hammer drill machine power,220volt input , angle grinder with 900watt motor,100mm disc , professional air blower equipped with //bid details 2 / 113 650watt , 400 amp 3 phase 4 pole manual changeover switch , 1,2 pvc water pipe , heavy duty foldable step ladder-5 step powder coated stee , double side silicon tape heavy duty transparent with strong adhesive , double side foam tape with strong adhesive

State Government

CTN :43514531 Due date: 03 Feb, 202603 Feb, 2026 55.81 Lacs
Tender For corrigendum : supply of electrical items for repair and maintenance of electrical installation at iiser bhopal - supply of 22 (+/-2) watt led tube light betten t-5 made of aluminium/pc body with pc diffuser with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt, and p.f>0.9. the cct of led used should be between 5700k to 5000k only. (make: havells/crompton/philips/wipro/orient/panasonic/ jaquar)., supply of 10 (+/-2) watt led tube light betten t-5 made of aluminium/pc body with pc diffuser with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt, and p.f>0.9. the cct of led used should be between 5700k to 6000k only. (make: havells/crompton/philips/wipro/orient/panasonic/jaquar)., supply of 38 (+/-2) watt recessed mounted 2x2 feet led light fitting with pc diffuser with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt and p.f>0.9, up to 2 kv surge protection. the cct of led used should be between 6000k to 6500k only (make-havells/crompton/philips/wipro/orient/ panasonic/jaquar), supply of 38 (+/-2) watt surface mounted 2x2 feat led light fitting with pc diffuser with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt and p.f.> 0.9, up to 2 kv surge protection. the cct of led used should be between 6000k to 6500k only (make-havells/crompton/philips/wipro/orient/ panasonic/jaquar)., supply of surface mounted ceiling light 18 watt led light fitting with pc diffuser with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt and p.f. 0.9, up to 2 kv surge protection. the cct of led used should be between 6000k to 6500k only (make:-havells/crompton/philips/ wipro/orient/ panasonic/jaquar)., supply of recessed mounted (11) ceiling light 22 (+/-2 watt led light fitting with pc diffuser with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt and p.f 0.9, up to 2 kv surge protection. the cct of led used should be between 6000k to 6500k only. (make-havells/crompton/philips/wipro/orient/ panasonic/jaquar), supply of surface mounted motion sensor ceiling light 10 watt led light fitting with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt and pf>0.9, up to 2 kv surge 6000k to protection. the cct of led used should be between (make-havells/crompton/philips/wipro/orient/ panasonic/jaquar) 6500k only, supply of 10 watt (+/-2 watt) bulkhead light fitting with inbuilt driver for proper driving of leds. the minimum system lumen output 100 im/watt and p.f>0.9, up 10 2 kv surge protection. the cct of led used should be between 6000k to 6500k only. (make:-havells/crompton/philips/ wipro/orient/ panasonic jaquar), supply of 10 watt track (study lamp) light fitting with inbuilt driver for proper driving of leds. the minimum system lumen output 100 im/watt and p.f>0.9, up to 2 kv surge protection. the cct of led used should be between 6000k to 6500k only. (make: havells/crompton/philips wipro/orient/ panasonic/jaquar), supply of 45 watt (+/-2 watt) streetlight fitting with inbuilt driver for proper driving of leds. the minimum system lumen output 100 lm/watt and p.f. 0.9, up to 2 kv surge protection. the cct of led used should be between 6000k to 6500k only. (make: havells/crompton/philips wipro/orient/ panasonic/jaquar), supply of aesthetically designed post top led luminaire smd of 40 w+ 5%, rated voltage 240v ac, 50 hz. ip 65 protection, system lumen efficacy > 90 lumens/w, voltage range 140-270 v ac, pf 20.95, cct: 5700k-6500 k, thd-10%, cri->70, operating temperature 0°c to 50°c, (make havells/crompton/philips/wipro/orient/panasonic/ jaquar)., supply of aesthetically designed tripod style inverted pyramid bollard of 0.8m to 0.9m heighted led light of 10 (+/-) 2 w at 230 v ac operation, ip 65 protection, voltage range 150-260 v ac, pf>0.9, cct: 5400k 6500k, surge protection 4.5kv made up of aluminium casti

CTN :43696083 Due date: 02 Feb, 202602 Feb, 2026 4.81 Lacs
Tender For supply of bollard light at environment light : : - supply and fixing garden light 10w cat no lblsn 10 cdl , supply and laying for cable in trenches or passing through pipe lt cable area 10 sqmm 4 core , excavating in trenches not exec 1 point 50 mtr wide and not exec 1 point 50 depth , returning filling in including levelling watering and well rammining in layer , removing excavated materials not exec 50 mtr , m and l sand cushioning in trench for protection of ug cables , m and l fly ash bricks locally available laid dry width wise across line of cable , m and l for pcc 1 ratio 3 ratio 6 type c2 using 40 mm graded aggregate as in foundation , m and l for pcc 1 ratio 2 ratio 4 type b1 using 20 mm graded aggregate as in foundation , high density polyehylene pipe rating 6 kgf cm2 fixed complete to walls , supply and fixing junction box 200x 160x98mm cat no k 9250 of hensel , m and l for earthing complete with galvanized plate 60cm x 60cm x 6mm as earth electrode
 Loading, Please wait...

Connect us via What's Up