Get complete information related to latest Solar Module Tester Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Solar Module Tester Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Solar Module Tester Tenders.
Tender For supply of vrf or vrv air cooled outdoor units suitable for cooling or heating having 100 percent hermetically sealed inverter type twin rotary or scroll compressor capacity of machines 14 hp to 22 hp , following minimum capacity 4 way vrv or vrf cassette type indoor ceiling mounted unit equipped with synthetic washable media pre filter,3 point 2 tr , following minimum capacity 4 way vrv or vrf cassette type indoor ceiling mounted unit equipped with synthetic washable media pre filter,4 tr , vaccumiazation and nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for vrv or vrf system, thickness 1 point 2 mm , 9 point 5 mm dia od soft drawn with tube thickness 1 point 2 mm , 12point 7 mm dia od soft drawn with tube thickness 1point 2 mm , 15 point 86 mm dia od soft drawn with tube thickness 1point 2 mm , 19 mm dia od hard drawn with tube thickness 1 point 2 mm , 22 point 2 mm dia od hard drawn with tube thickness 1 point 2 mm , 25 point 4 mm dia od hard drawn with tube thickness 1 point 2 mm , 28 point 58 mm dia od hard drawn with tube thickness 1 point 2 mm , 34 point 9 mm dia od hard drawn with tube thickness 1 point 62 mm , 41 point 27 mm dia od hard drawn with tube thickness 1 point 62 mm , s i t c of y joints kit refrnet , drain piping rigid pvc piping complete with fittings supports as per specifications and insulated with 6mm thick closed cell elastometric nitrile rubber insulation 25mm dia and , 32 mm dia , 40mm dia , control and transmission wiring , testing and commissioning of vrf or vrv systems including topping of r410a gas as per site requirements , supply and installation of u or v protection of used copper pipe at outer site for odu connection site , 6way load bank double door enclosure confirming to is 8623 iec 60439 g frame panel boards , supplying and fixing of following sizes of medium class pvc conduit along with accessories 25mm , frlsh or hffr pvc insulated copper conductor single core cable in the existing surface or recessed steel or pvc conduit as required 3 x 1 point 5 sq mm , suitable size gi box with modular plate and cover in front on surface or in recess , one number xlpe insulated and pvc sheathed copper conductor armoured power cable of 1 point 1 kv grade 4 x 16 sqmm , 16 a rating 240 by 415 v 10 ka c curve miniature circuit breaker suitable for nductive load of following poles in the existing mcb db complete with connections single pole , single pole and neutral sheet steel mcb distribution board 240 v on surface by recess complete 12 way double door , supplying and fixing 25 a rating single pole and neutral , following size of perforated painted with powder coating m s cable trays 150 mm width x 50 mm depth x 1point 6 mm thickness , earthing with g i earth pipe 4 point 5 metre long 40 mm dia including accessories , providing and laying earth connection from earth electrode , providing and fixing 6 swg dia g i wire on surface or in recess for loop earthing , amc as per section c , installation of cassette ac 2 ton 5 star , copper pipe , 4 core copper wire , drain pipe with insulation , odu stand , cable tray , hanging rod , faster nut , wrapping tape , 3 core copper wire
Tender For supply of one set of development & testing kit for locomotive control electronics (dsp card& repair work), consisting of three items as per attached annexure-1. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of acidity testing kit for transformer oil. kit consists of following 06 items. 1) polythene bottles containing 100 ml each of ethyl alcohol and sodium carbonate solution of 0.0085n concentration. 2) an indicator bottle containing universal indicator. 3) 4 nos. clear glass test tubes. 4) 3 nos. graduated droppers, which serve as pipettes. 5) colour chart calibrated with neutralisation number values. 6) instructions booklet. acceptable makes: utc, metravi or simlar. [ warranty period: 12 months after the date of delivery ] ]
Tender For supply, installation, testing and commissioning of mica undercutting machine, stator holding ring rotating, voltage drop tester, hydraulic bearing pullers with hydraulic cylinders, three leg bearing puller (manual), digital motor checker, bearing fitting tool kit and bearing induction heater
Tender For corrigendum : supply of hv switchboards c c - supply 6.6kv switchboard at manmad pumping station tag no-hv swbd-1-manmad as per mr sl. no. 1.1 , supply 6.6kv switchboard at manmad pumping station tag no-hv swbd-2-manmad as per mr sl. no. 1.2 , mandatory spares for hv swbds at manmad terminal as per mr sl. no. 1.3 , supply 6.6kv switchboard at sanghvi pumping station tag no-hv swbd-1-sanghvi as per mr sl. no. 1.4 , supply 6.6kv switchboard at sanghvi pumping station tag no-hv swbd- 2-sanghvi as per mr sl. no. 1.5 , supply 6.6kv switchboard at sanghvi pumping station tag no-hv swbd-3-sanghvi as per mr sl. no. 1.6 , mandatory spares for hv swbds at sanghvi terminal as per mr sl. no. 1.7 , supply 6.6kv switchboard at gujri pumping station tag no-hv swbd-1- gujri as per mr sl. no. 1.8 , supply 6.6kv switchboard at gujri pumping station tag no-hv swbd-2-gujri as per mr sl. no. 1.9 , mandatory spares for hv swbds at gujri pumping station as per mr sl. no. 1.10 , supervision of installation work at manmad as per mr sl. no. 1.11 , performing testing and commissioning activities at manmad as per mr sl. no. 1.12 , supervision of installation work at sanghvi as per mr sl. no. 1.13 , performing testing and commissioning activities at sanghvi as per mr sl. no. 1.14 , supervision of installation work at gujri as per mr sl. no. 1.15 , performing testing and commissioning activities at gujri as per mr sl. no. 1.16 , on call visit charges for amc for 1st year at manmad as per mr sl. no. 1.17.1 , testing kit mobilizing charges for 1st year as per mr sl. no. 1.17.2 , on call visit charges for amc for 2nd year at manmad as per mr sl. no. 1.17.3 , testing kit mobilizing charges for 2nd year as per mr sl. no. 1.17.4 , on call visit charges for amc for 3rd year at manmad as per mr sl. no. 1.17.5 , testing kit mobilizing charges for 3rd year as per mr sl. no. 1.17.6 , on call visit charges for amc for 1st year at sanghvi as per mr sl. no. 1.18.1 , testing kit mobilizing charges for 1st year as per mr sl. no. 1.18.2 , on call visit charges for amc for 2nd year at sanghvi as per mr sl. no. 1.18.3 , testing kit mobilizing charges for 2nd year as per mr sl. no. 1.18.4 , on call visit charges for amc for 3rd year at sanghvi as per mr sl. no. 1.18.5 , testing kit mobilizing charges for 3rd year as per mr sl. no. 1.18.6 , on call visit charges for amc for 1st year at gujri as per mr sl. no. 1.19.1 , testing kit mobilizing charges for 1st year as per mr sl. no. 1.19.2 , on call visit charges for amc for 2nd year at gujri as per mr sl. no. 1.19.3 , testing kit mobilizing charges for 2nd year as per mr sl. no. 1.19.4 , on call visit charges for amc for 3rd year at gujri as per mr sl. no. 1.19.5 , testing kit mobilizing charges for 3rd year as per mr sl. no. 1.19.6 , site training for hv swbds supplied at manmad as per mr sl. no. 1.20 , site training for hv swbds supplied at sanghvi as per mr sl. no. 1.21 , site training for hv swbds supplied at gujri as per mr sl. no. 1.22 , unit rates for test as per attached annexure-1 as per mr sl. no. 1.23 , unit rates for 2 years o and m spare as per clause no. 4.5.3 as per mr sl. no. 1.24
Tender For supply, installation and testing of electronic equipments - supply -ece lab equipments, single output regulated dcvariable power supply- input voltage: 230v / 50hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., dual output regulated dc variable power supply- input voltage: 230v/50 hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., function generator - frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display. output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range. power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v, digital ic trainer kit with breadboard - +5 v dc, 1 a regulated power supply. 12 v dc / 15 v dc, 200 ma regulated power supply. solderless breadboard with minimum 840 tie- points,power distribution buses. zif (zero insertion force) ic sockets to accommodate 8 or 16 pin ics. logic input and output leds for output monitoring. 16 buffered led outputs. 16 debounced switch inputs. variable clock generator: 0.5 hz to 50 hz. single pulse output: 100 ms (buffered, positive and negative outputs). one seven-segment display with 4 bcd inputs. built-in logic switches. manual clock: debounced push-button (one pulseper press)., dc voltmeter(digital) - dc digital voltmeter - 3 digit led/lcd display, measurement range: 0 20 v dc,accuracy: class 0.5( 0.5 % full-scale), dc ammeter - dc ammeter digital - 3 digit led/lcd display, measurement range: 0 5 a dc,accuracy: class 0.5 ( 0.5 % full-scale), lvdttrainer kit - ac mains power supply: 230 v 10%, 50 hz. fixed regulated dc power supply: +5 v, 12 v / 500 ma. transducer: lvdt. lvdt displacement: 20 mm (40 mm total). displacement scale: linear 20 mm. displacement display: red color 3 digit led display. excitation frequency: 4 khz. excitation voltage: ac variable excitation voltage up to 5 v., strain gauge trainer kit - ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. instrumentation amplifiers with 3 digit display for strain / output voltage. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual., ask modulation and demodulation kit - message signal1:8-bit variable data,amplitude 5v. message signal 2:debounced data, amplitude low (0) and high (5 v). message signal 3:fixed data 25 khz, 12.5 khz, 6.25 khz, 3.12 khz,amplitude 5 v. carrier signal: sine wave, frequency 200 khz, amplitude 5 v. supply voltage (board): +12 v, +5 v dc. input voltage: 230 v ac, 50 hz. interface connectors: 2 mm banana socket., fpga trainer kit - must use industry-standard mid-range fpga device usb-jtag programmable, compatible with vivado ise (webpack). power supply: 5 v dc through usb or external adapter. on-board peripherals: leds, switches, push buttons, 7-segment display,clock source, gpio / pmod expansion ports, uart, vga / hdmi, usb- uart bridge, usb cable. user manual., measurement scale: a vertical steel meter scale, usually with (1mm) graduations, for precise deflection measurement., accessories: includes a set of slotted weights (e.g., (6times 50g) or similar sets) for incremental loading.