Tender For corrigendum : rate contracts for radiology interventional procedures supply for the year 2026-2027 & 2027-2028 - peripheral self expanding stent, 6 fr, otw, nitinol based, open/ closed cell/ hybrid design, with distal and proximal markers made of tantalum/ gold (for better visibility), should be 6 fr compatible. should be electropolished for better visualization under fluoroscopy. should have good radial strength. shaft length should be maximum 80 cm. - for biliary use., 250, 0.035", 4, diameter: 10 to 20 mm, length: 40 to 200 mm, peripheral self expanding stent, -, otw, nitinol based, encapsulated between 2 layers of eptfe, carbon coating in inner lumen. should have flared ends., 5, 0.035", 8, diameter: 5 to 10 mm, length: 10 to 60 mm, peripheral balloon expandable stent, -, otw, cocr/ stainless steel based, encapsulated between 2 layers of eptfe., 5, 0.035", 12, diameter: 4 to 8 mm, length: 10 to 40 mm, peripheral balloon expandable stent, -, stent for dedicated use in trans jugular intrahepatic porto systemic shunt. should have both covered and uncovered parts in 1 stent., 1, 0.035", 16, diameter: 4 to 8 mm, length: 10 to 40 mm, coronary stent graft, -, otw, nitinol based, fully covered, percutaneously retrievable (via ptbd access), with long radioopaque string, 1, 0.014" / 0.018", 20, all sizes, ureteric stent, -, should be made from pu material. should have 2 pigtail loops., 50, 0.035", 24, 260 cm, amplatz guide wire, -, amplatz super stiff guide wire j tip/ straight tip / angled tip, 100, 0.035", 28, 150 cm, angiographic guide wire, -, angiographic guide wire, hydrophilic coated, angled tip, 25, 0.035", 32, 260 cm, angiographic guide wire, -, hybrid angiographic guide wire, shoould be kink resistant, should come with distal 25 cm atraumatic hydrophilic coated tip, should have nitinol core, angled tip, 5, 0.014", 36, 150 cm, angiographic guide wire, -, angiographic guide wire with long tapered tip load of 6 gm, 5, 0.018", 40, diameter: 3 to 10 mm, legth: 40 to 300 mm, peripheral semi compliant balloon, -, otw, with low entry profile, markers at proximal and distal tip of balloon, 5, 0.035", 44, diameter: 12 to 26 mm, legth: 20 to 60 mm, peripheral non compliant balloon, -, otw, non compliant balloon, should have rbp of at least 18 atm, 5, 0.035", 48, diameter: 2 to 6 mm, legth: 10 to 40 mm, coronary noncompliant balloon, -, soft, compliant, with proximal and distal radio opaque markers, 5
Tender For srphc82281240-coronary drug eluting stents with (1) stent on cobalt chromium alloy or platinum chromium alloy. (2) stent with coating of polymer carrier for active drug ( sirolimus everolimus or zotarolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.5mm to 4mm and length of the stent should be 12mm to 48mm. (4) the strut thickness should be 91 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapidexchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval should be enclosed in the tender bid. (9) the long term efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals. (10) the documents related to the efficacy and safety of the stent should be only for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of thestent to a major government institute. unit:no [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of hq_med_sur_ph:.(153049) drug eluting coronary stent system - platinum chromium hdvd - pvf everolimus drug eluting stent 2.25 mm to 4 mm all size ]
Tender For hq_med_sur_zrc_zonal rate contract for supply of ph:.(153045) sirolimus eluting stent cobalt - chromium stent with abluminal coating and specialised gradient coating (no polymer coating at joint & bends). bioresorbable polymer of plcl (poly lactic acid + poly caprolactone pcl) with degradation time of 3-4 months. low concentration of sirolimus (0.8ug/mm sq) should have bio-inspired open-cell. pmda approved ]
Tender For e-tender for the supply of various implants and consumables for department of cardiology of r.g. kar mch - temporary pulse genarator - single chember with patient cable(rates for each sub item must be given, cummulative lowest bidder will be treated as l1 bidder), temporary pulse genarator - single chember, patient cable for temporary pulse genarator - single chember, carotid balloon, close tapered carotid stent, single size distal protection device, bmv ballon with set, conduction system pacing - assorted sizes(rates for each sub item must be given, cummulative lowest bidder will be treated as l1 bidder), lbbb lead for conduction system pacing, his sheath for conduction system pacing, slitter for conduction system pacing, coronary snare system, guide extention catheter, amplatz super stiff wire - ptfe coated, distal spring coil, 260cm, coronary cover stent, long sheath - assorted sizes, peripheral angioplasty balloon - assorted sizes
Tender For supply of polymer free sirolimus eluting coronary stent, with microporous surface, abluminal coating, shellac resin and 10 years of safety and efficacy data. warranty: replacement warranty against any manufacturing defect noted on the o.t. table. [ai(2026-27), item code-no: s-62284, sl no.2183] ]
Tender For supply of drug eluting stent -sirolimous drug with biodegrable polymer on cobalt chromium platform with active coating. size ranging from length 08 mm to 48 mm and width 2.25 mm to 5.0 mm. the quoted stent to be at least dcgi approved and three years efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented/published in peer reviewed scientific journals. the documents pertaining to the efficacy and safety of the stent should be enclosed for the brand that is offered in the tender bid. replacement warranty against any manufacturing defect noted onthe o.t. table. the original company brochure mentioning the range of sizes (diameter & length) should besubmitted along with tender. [ai(2026-27), item code-no: s-62066, sl no.2010] ]
Tender For empanelment for the supply of cathlab items on running contract basis under kasp and other schemes of this hospital - coronary stents, des,everolimus,fda/dcgi/ce approved platinum chromium platform,polyvinylidene fluride-hexafluropropyline pvdf-hfp polymer-stent lengths8,12,16,24,28,32. stent diameter 2.25*,2.50,2.75,3.00,3.50,4.00.struct thickness 81/86 microns.nominal pressure - 11 atm,rated burst pressure 16-18 atm, des,everolimus,fda/ approved platinum chromium platform,polyvinylidene fluoride-hexafluropropylene(pvdf-hfp)polymer, des,everolimus,fda/dcgi/ce/ approved platinum chromium platform,bioabsorbable polymer plga, everolimus eluting platinum chromium stent system, des, everolimus, l 605 cobalt chromium with hybrid cell design , strut thickness- 65microns, polymer- plga diameter- 2.25, 2.5, 2.75, 3.0, 3.5,4. length- 10,13,15,18,20,24, 28, 32,36,40, 42, 44, des, everolimus, cobalt chromium strut thickness - 63 microns . diameter- 2.25,2.5,2.75,3,3.5,4. length- 8,10,13,15,18,20,24,28,32,36,40,42,44. elutes 80% of drugs along with re plga polymer in the first 20 days, dcgi approved everolimus drug eluting 65 micron strut thickness with 3 micron plla&plga. a unique proprietory coating technology basedbiodegradable polymer stent with open cell designed and flexia finished technology based cobalt chromium l605 stent.a designed for optimal strength, flexibility ,trackablity ,side branch supported,bifurcation supported and high radial strength and optimal radiopacity and excellent vessel supported stent with revers alternative link design(ral) stent, with length from 8 mm to 52 mm and diameter from 2.25 mm to 4.50 mm, ce approved everolimus eluting coronary stent system struts/cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. the cell angle is between 42 degree to 57 degree with respect to different diameter. the cells are connected by link (mid to mid pattern) with a radius of 0.2700mm. these values have been validated for lower stent profile, uniform expansion, side branch access, good trackability & strong radial support. components - drug: everolimus, stent platform: cobalt chromium l605 alloy, polymer: biodegradable, catheter: ptca rapid exchange semi-compliant stent delivery catheter. drug concentration: 1.2 microgram/mm2 of stent surface area. stent diameter(mm): 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & stent length (mm): 8, 13, 16, 20, 24, 28, 32, 36, 40, 43, 47 platinum-iridium radiopaque markers are precisely placed within the balloon cones for accurate stent positioning, also the difference between stent edge to marker is 0.5mm (atboth sides, proximal & distal) which prevents the dogboning during the angioplasty., ce approved sirolimus eluting coronary stent system struts/cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. the cell angle is between 42 degree to 57 degree with respect to different diameter. the cells are connected by link (mid to mid pattern) with a radius of 0.2700mm. these values have been validated for lower stent profile, uniform expansion, side branch access, good trackability & strong radial support. components - drug: everolimus, stent platform: cobalt chromium l605 alloy, polymer: biodegradable, catheter: ptca rapid exchange semi-compliant stent delivery catheter. drug concentration: 1.2 microgram/mm2 of stent surface area. stent diameter(mm): 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & stent length (mm): 8, 13, 16, 20, 24, 28, 32, 36, 40, 43, 47 platinum-iridium radiopaque markers are precisely placed within the balloon cones for accurate stent positioning, also the difference between stent edge to marker is 0.5mm (atboth sides, proximal & distal) which prevents the dogboning during the angioplasty., only dcgi approved everolimus eluting coronary stent system struts/cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. the cell angle is between 42 degree to 57 deg
Tender For supply of srphc 82281043-aortic stent graft balloon expandable pre-mounted covered stent made of cobalt-chromium alloy with eptfe covering. should be available in range of lengths from minimum of 19 mm to 59 mm and diameters from minimum 12 mm to 24 mm or above. stent should have dcgi approval. [ warranty period: 30 months after the date of delivery ]
Tender For supply of flow diverter stent for intracranial aneurysm therapy , complex finish coil (3d shape) 10 system extra soft profile for brain aneurysm treatment, size ran , intracerebral distal access catheter for intracerebral endovascular use (like catalyst 5)