Get complete information related to latest Sound Recording Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Sound Recording Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Sound Recording Tenders.
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to
Tender For purchase of equipments for ece department - function generator frequency range: 0.1 hz to 5 mhz display: 4 to 6 digit led display output waveforms: sine, triangle, square, pulse, ramp . amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v, strain gauge trainer kit ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual., temperature measurement kit sensors: rtd (pt-100), thermocouple (fe-k/j-type), and/or thermistor (ntc). display: 3 digit led/lcd digital display (typically 200 mv fsd). temperature source: portable water kettle or heater block. signal conditioning: on-board circuitry for amplification, linearization, and cold junction compensation. test points: multiple 2 mm / 4 mm banana sockets for monitoring input/output signals. power supply: 230 v ac, 50 hz, single-phase. accessories: glass thermometer, 10 k ntc thermistor probe, k-type thermocouple probe, patch cords and user manual., cathode ray oscilloscope bandwidth: dc to 30 mhz (-3 db) - sensitivity: 1 mv/div to 5 v/div - display modes: ch1, ch2, dual (chop/alt), add, sub - timebase: 0.2 s/div to 0.5 s/div (essential for slow bio-signals) - magnification: x 10 sweep magnifier - triggering: alt triggering, auto, norm, - tv-v/h with source selection (ch1, ch2, line, ext). - input impedance: 1 mohm || 25pf - included accessories: two 60 mhz passive probes, power cord, and user manual
Tender For corrigendum : supply of consumables for pathology dept - pbs powder ph 7.0 to 7.5 500gm , ssc 20x solution , bcr abl1 probe fusion probe , her2nue probe amplification probe , dapi antifade for fish , anti body fitc c1q for direct immunofluoresence , xl aml1 eto xlt 8 isto 2 translocation dual fusion 100 micro litre fish probe , xl pml rara xlt is isto 17 translocation dual fusion 100 microlitre fish probe , proteinase k powder from tritirachium album 100mg , ana anti nuclear antibody. indirect immunoiflourescence assay kit , dna ffpe kit 250 reaction , egfr mutation diagnostic kit 29 targets 52 reaction real time pcr. detection includes controls , microtips 10 microlitre , advance hydrophobic pen for ihc. please refer pdf file for speicification
Tender For corrigendum : supply of boq bid for kits related to cobas 4800 analyzer c c - cobas 4800 system sample preparation kit 240t ivd , cobas 4800 system wash buffer kit 240t ivd , cobas 4800 hpv controls 10 sets ivd , cobas 4800 hpv amplification- detection kit , kit cervical collection brush -bulk , roche cell collection media , extraction deep well plate 2 ml , ad plate zero point three ml , cobas 4800 system liquid cytology preparation kit 240 t ivd , tip core tips with filter 01ml