Tender For corrigendum : providing of testing service for on-board /commissioned equipment/ instrument related to plant - ndt; deflection measurement data (load test), magnetic particle testing, ultrasonic testing facility, penetrant testing facility; nabl labs
Tender For providing of testing service for on-board /commissioned equipment/ instrument related to plant - ndt; crack width measurement in reinforcement concrete structures, rebound hammer test, ultrasonic pulse velocity tests, half cell potential difference test, visual e..
Tender For corrigendum : providing of testing service for on-board /commissioned equipment/ instrument related to plant - wt-5194g work of dye penetrant test dpt magnetic particle inspection mpi internal oxide scale measurement iosm hardness testing during aoh coh r m and as and when req..
Tender For procurement and supply of medical equipment for various dept. to government hospitals / institutions in telangana state under rate contract for a period of 2 years - fibrillating machine, miraq transit time flow measurement ttfm instrument to access coronary graft flow, cardio thoracic surgical instrument, minimally invasive coronary mic equipment, hand held doppler, vat equipment, holter monitoring system, electro convulsive therapy ect machine, psychological tests - 20 tests, ultrasonic nebulizer, spirometry, rigid thoracoscope - vats, video polysomnography
Tender For corrigendum : supply of spares for 100kn servo electric utms - limit switch for kappa 100ss-cf, p/n z108.057, limit switch for hydraulic adjustment, p/n z108.078, remote control for setting up inching operation, p/n mp02489, usc module kappa, universal measurement amplifier, for connecting resistive and inductive bridge sensors, choice of ac/dc power supply, 4 and 6-conductor technology, 24-bit calculated resolution, module occupies one module bus slot, p/n mp00525, insulation end disc half, ultiform uvs 144, p/n z551.004-014, heating element kanthal apm, id 5 in, length 4in, fur 1250 °c p/n z906.072, furnace insulation vertical plate, p/n z551.004-010, furnace thermocouple type s for 5" furnace incl. compensating cables, p/n z551.034, solid state relais 30a/660v for ht-controller 1200°c p/n 930.ssm1a130bd, moving iron instrument 0...5a/10a, p/n 930.eq48, power supply 24 v, p/n 930.2868635, contactor tesys 7.5 kw, p/n 930.lc1d18bl, extension cable hiperface for tcii, p/n 977.066342, external power supply 48v/10a, p/n z240.054-011
Tender For supply of liner bite measurement instrument model lcg-1(specification- measuring accuracy - 0.02 mm.measuring range 0-20 mm least count 0.01 mm measuring reference base 120 mm approx. height 112 [ warranty period: 30 months after the date of delivery ] ]
Tender For supply, delivery and installation of advanced testing mechanism, lab equipment for conducting daily quality of drinking water in tanuku municipality supply, delivery & installation of compact photometer pf-12plus make: mn, germany (or) any equivalent isi make model no: 919250 technical specifications: type: filter photometer with microprocessor control, self-test and auto-calibration light source: xenon lamp optical system: automatic filter wheel with 7 interference filters wave length: 345 nm / 436 nm / 470 nm / 540 nm / 585 nm / 620 nm / 690 nm plus 1 compartment for an additional filter, 860 nm led for ntu measurement wave length accuracy: ± 2 nm, bandwidth at half transmission: 10 nm?12 nm photometric range: ± 3 e photometric accuracy: ± 1 % long term stability: < 0.002 a/h measuring modes: more than 100 preprogrammed tests and special methods, absorbance, transmission, factor, standard, nephelometric turbidity measurement; 50 freely programmable methods pre programmed tests: nanocolor tube tests, visocolor eco tests and powder pillows turbidity measurement: nephelometric turbidity measurement at 860 nm (based on iso 7027), 1?1000 ntu cuvette slot: round tubes 16 mm od data memory: 1000 results, glp conform display : backlit graphic display, 128 x 64 pixel auto off: inactive or automatic shutdown after 5 min, 10 min, 15 min, 20 min, 60 min internal quality control: with nanocontrol nanocheck 2.0 operation: self-explanatory menu guidance, plastic foil keypad, test selection via parameter lists language: de / en / fr / es / it / nl / hu / pl / pt / cz / id / sl / tr / my operating range: 10?40 °c (50?104 °f), max. 80 % relative humidity (non-condensing) power supply: via usb power supply, standard or rechargeable batteries or accu-pack weight: 0.7 kg dimensions (l x w x h): 215 x 100 x 65 mm scope of delivery photometer, software dvd, manual, visocolor eco test instructions, 4 batteries, 4 empty test tubes, funnel, beaker, syringe, usb cable, calibration cuvette, cleaning cloth and certificate in rugged case hazardous material: no , supply, delivery & installation of mm42dp-ph,ec,tds portable multi-parameter water quality meter with ph, conductivity electrodes. includes: mm-42dp(main unit)+mm4-ph(1m) ph electrode+mm4-ec(1m) ec electrode make: dkk-toa corporation, japan. technical specifications : measuring method : ph : glass electrode method orp : platinum electrode method conductivity : ac bipolar method dissolved oxygen : optical type temperature : thermistor resistor display unit :custom lcd(with backlight) measurement items/ranges : ph : ph0.000 to ph14.000 mv (orp) : -2000 to 2000mv conductivity:0.1ms/m to 10s/m d0: 0.00-20.00mg/l or 0.0 to 200.0% electrical resistivity:0.1o.m to 10ko.m (converted from electric conductivity) salinity (nacl):conversion from electrical conductivity salinity (pss: practical salt):conversion from electrical conductivity total dissolved solids (tds):conversion from electrical conductivity temperature:0.0to100.0°c display range : ph : ph-2.000to ph16.000 mv (orp) : 0to99.99mg/l 0to999.9mg/l 0to9.999g/l 0to99.99g/l 0to999.9g/l (automatic/manual range switching) temperature :-5.0to110.0°c do:0.00-22.00mg/l or 0.0 to 220.0% display resolution : ph :0.01ph/0.001ph mv (orp) :1mv conductivity :0.05%fs electrical resistivity :0.05%fs, salt :0.01%(nacl)0.01psu(pss) total dissolved solids (tds) :0.01%fs temperature :0.1°c, repeatability (instrument body): ph :within ±0.006ph mv (orp) :±2mv, conductivity :±0.5%fs, do:when combined with 8mg/l ±0.1mg/l or 100%±1% electrical resistivity :±0.5%fs salt :±0.5%fs, total dissolved solids (tds) :±0.5%fs temperature :within ±0.2°c ph temperature compensation range: atc (automatic temperature compensation): 0 to 100.0? mtc (manual temperature compensation): 0 to 100.0? electrical conductivity temperature compensation range : atc (automatic temperature compensation): 0 to 100.0? mtc (manual temperature compensation): 0 to 100.0°c atc off (no temperature c
Tender For bid to ras bid to ras providing of testing service for on-board /commissioned equipment/ instrument related to plant - ndt; carbonation test, crack width measurement in reinforcement concrete structures, deflection measurement data (load test), half cell potential difference test, reb..
Tender For supply of ir lamp , weight measurement with bmi fat percentage , distance vision chart , cvolour vision chart , suction apparatus prtable , instrument tray with lid l , instrument tray with lid m , hp drum deep for sterile guaze , forceps artery , oxygen cyilnder , iv stand , medicine box plastic , rectal thermometer , bowl big size , tourniquet
Tender For digital hand held lcr meter 4 1/2 digit (dual display) model no.916 with accessories kit including alligator clips, smd test probe, a usb cable & an ac adaptor. make : gw instek or m/s extech or scientific or its equivalent. specifications: 1) measurement parameters : l,c,r (ac/dc), d, q, esr, phase angle; 2 wire or 5 wire measurement. 2). testing mode : parallel / series ; sorting mode for quality control. 3) full scale : main display : 20,000 / 2,000 count selectable. sub display : 2,000 count. 4) freq: 100 hz, 120 hz, 1khz, 10khz & 100khz. 5) auto lcr mode : automatically identifies and measures the dut when the meter is switched on. 6) other functions : auto range, auto back light, max, min, data hold, zero, 46 segments analogue bar, auto power off. 7) display: lcd mono display. 8)interface : usb 9) power supply : 6 volts battery & optional power adopter. 10) low battery indication. the firm must supply proper calibration certificate(from nabl approved lab) with the instrument. [ warranty period: 30 months after the date of delivery] ]