Web Analytics Made Easy - StatCounter

Speed Monitoring Machine Tenders

Get complete information related to latest Speed Monitoring Machine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Speed Monitoring Machine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Speed Monitoring Machine Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40985783 Due date: 28 Jul, 202528 Jul, 2025 1.50 Crore
Tender For purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat a

Central Government / Public Sector

CTN :40974759 Due date: 15 Jul, 202515 Jul, 2025 NA
Tender For providing of custom bid for services - annual maintenance contract of gas monitoring system (gms), interlock shutdown system (ilsd) & rovs at lpg bottling plant, leh ladakh oem m/s pentax engineering pvt ltd

Co-operative

CTN :40969595 Due date: 19 Jul, 202519 Jul, 2025 NA
Tender For supply and installation and commissioning of spm analyzer - supply, installtion & commossioning of spm analyzer with tuv. as per specifications, the system should have the below features as desired by cpcb.a) the spm analyzer should have continuous quality check for zero and spa point, prferably without human intervention to ensure continuous daya validity and credibility. (please refer guidelines for continuous emission monitoring system july 2017 page 8/100)b) the system should have feature of automatic range setup.c) the system does not required manual adjustment and should operate without any human intervention.d) the system should have autotic drift compensation.e) the system doen not have optical windows to be cleaned.f) the system should not required any alignment for smooth operation.g) the system doen not have any effect of vibrations on the system accuracy and readings.h) the system should have tuv with qal (en15267 parts 1 to 3) with appropriate certification range as per cpcb guidelines.measurement principle: inductive electrificationmeasurement objects: solid particles in a gas flowparticle size : 0.3 um or largermeasurement range: approx 0.1 mg/m3 to 1 kg/m3probe length: as per requirement (standard 500,750,1000,1500,2000 mm)probe dia: 10 mm, max temperature: upto 300 degree c. (optional upto 700 degre c)max pressure: 3 bargas velocity: min 4 m/sresponse time: less than 1 secondself zero span check: yessignal averaging: adjustable 0-300 seondoutput signals: isolated 4-20 ma serial communicaiton rs-485 modbus - two spdt relays:5a-24 vac/dcambient temperature: 20 to +60 degree chumidity: 95% rh (non- condensing)vibration: 5 m/s2 or lessprobe: ss316 linsulation of probe: peekenclosure: aluminmb alloypower supply: 230 vac, 15 vac, 24 vdcpower consumption: 3 wprotection: ip65certification: tuv with qal1, chief engineer

CTN :40941178 Due date: 14 Jul, 202514 Jul, 2025 NA
Tender For e-tender for supply of cytology & pathology kits medicine - blood oxygenator membrane (adult ), blood oxygenator membrane pediatric, blood oxygenator membrane infant hardshell reservoir capacity of maximum 3.6 lit, custom pack tubing set jipmer circuit v (adult), custom pack tubing set jipmer circuit v - b (pediatric) for cardiopulmonary bypass, hemofilters (adult type) for modified ultra filtration :, hemofilters (pediatric type) for modified ultra filtration, arterial filters for adult circuit, heart valve mechanical prosthetic bileafiet ( position) various sizes, heart valve mechanical prosthetic bileafiet (aortic position) various sizes, cardiac suction tube 10f, perfusion adapter 1 : a male luer at one end and a barbed 1/4" connector, perfusion adapter 2 : three way stop-cock with male & female luer ends and a barbed 1/4" connector, perfusion adapter 3 : antegrade & retrograde, heart valve mechanical curved leaflets mitral position various sizes, heart valve mechanical curved leaflets aortic position various sizes, bioprosthetic valve (bovine pericardial) - mitral tissue valves of various size, bioprosthetic valve (bovine pericardial) -aortic valves of various size, annuloplasty rings for mitral valve (complete ring type), annuloplasty rings for mitral valve semi rigid complete ring (rigid posteriorly and flexible interiorly), annuloplasty rings for tricuspid valve anatomically shaped 3 dimensionasize: 26, 28, 30, 32, 34 & 36 mm, sauvage filamentous knitted polyester fabric 2x2 inch, vascular grafts i, vascular grafts ii, vascular grafts iii, vascular grafts iv, disposable aortic vascular punch, disposable bull dog type, arterial embolectomy catheter sizes all, balloon carotid shunts with stopcock: size: 9 & 11 f and 30 cm,, vascular clip applicator (medium size) for large vessels with 1000 vascular clips, vascular clip applicator (small size) for small vessels (internal mammary) with 1000 vascular clips, disposable chest drainage ( underwater seal), sterile incision surgical drape, hand held pencil switch twin type, long armed hand held pencil switch, durable non-adhering & stretchable, disposable suction tubing, disposable pressure monitoring, pressure infusion bags 1 lit, pressure infusion bags 500 ml, intra venous cannula without injection port 35 & 51 mm long, size 20g, intra venous cannula without injection port 35 & 51 mm long, size 22g, long peripheral venous catheter (for central venous infusion) of various sizes, in-dwelling arterial catheter preferably with self adapter - various sizes, medical grade pvc snuggers (adult & pediatric) for purse string sutures, hemoglobin rapid test strips (500 numbers) with testing machine, sternal fixing bands, ecg electrode, chamber set, intra aortic balloon 30cc and 35cc, intra aortic balloon 40cc, connectors for cpb circuit, hemocor hph 1000 pts 400ml/mini ultrafiltration rate, hemocor hph 400 pts 400ml/mini ultrafiltration rate, quick prime line, vascular cannula atraumatic spring clips, ventilator tubing with hme 4 meter length, bear hugger and warming blankets, abg machine solutions (4 bott. pack), sternal wires size 20,22,24, dacron sauvage filamentous patch 4"*4", thoracic drainage catheter 24/28/32, ioban 3m, a.c.t. cartridges (celite & kaoline act tubes ) 50*2, ascending aortic rotatable valve conduct, eptfe strech vascular graft all sizes, transeptal mullin sheath all sizes, transeptal puncture needle all sizes, hypo allergic adhesive paper tape all sizes, continious cardiac output monitor with svo2 catheter, incise drape with iodine release, sterile all sizes, heat moisture exchange filter, anesthesia face mask adult/paed, bulldog clamp, disposable cardioplegia delivery system, non-traumatic gloves sterile with gama rays all sizes, sterile surgical blade with handle all sizes (disposable), bacterial gas filter, y - connector for retrograde cannula, vessul cannula, rigid suction device, burette set, oxidised celullose spray of 2

Central Government / Public Sector

CTN :40916417 Due date: 11 Jul, 202511 Jul, 2025 6.15 Lacs
Tender For providing of custom bid for services - annual maintenance contract of gas monitoring system

CTN :40839369 Due date: 16 Jul, 202516 Jul, 2025 1.50 Lacs
Tender For procurement of ldpe tube for tube bundle gas monitoring system working at alp mine
 Loading, Please wait...

Connect us via What's Up