Web Analytics Made Easy - StatCounter

Spike Protector Tenders

Get complete information related to latest Spike Protector Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Spike Protector Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Spike Protector Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government / Public Sector

CTN :45334427 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For (i) macls indoor and outdoor works along with provision of electronic interlocking at tadikalpudi & bethampudi stations. (ii) macls indoor and outdoor works along with provision of distributed electronic interlocking at bethampudi and telecommunication related works between 35.42km/tpy to 47.00/btpd in connection with doubling between dornakal - bdcr of sc division of s.c.railway. (iii) utility shifting and stage working also part of this work. (iv) optical fiber cable 2 x 48f to be laid on both side of the track in complete section given and to be matched and inbuilt block in ei to be used, fire aspiration, cctv, 24f to be laid for patching the sravaram stations and to be matched at btpd byepass cabin.

State Government

CTN :45313570 Due date: 09 Jun, 202609 Jun, 2026 NA
Tender For e-quotation for seeking firm rates for non-schedule items for preparing estimates. - s/i/t/c of new 80 hp vt pump set, supplying,installation,testing and commissioning of vt pumpset (confirming to is1710:2021 standards) with 35 ft suitable size ms column pipe assembly in random length of 5 ft.(make-jyoti/wpil/kirloskar) with ss/bronze impeller capable to discharge 216 m3/h against a total head of 68m coupled with vertical solid shaft tefc ie3,ip55 type squirrel cage induction motor (make-siemens/crompton/abb) operating on 3 phase 50 hz,415v+- 10% supply and having speed 1400-1500 rpm (bhp of motor should be 10% more than that of pumpset including cost pof supplying,fitting and fixing of all required accessories, repairing of 80 hp vt pump set at raw water, supplying all labour tools and tackles for taking out the 40hp vt pump set with bowl assembly, column pipe and line shaft etc., cost towards dismantling of complete bowl assembly., cost towards repairing and fitting the parts of vt pumpset as per requirement (works as complete overhauling of the pump) such as:-1.machining/lathe work 2.changing ss top shaft,line shaft(2 nos of 5 feet) of and bottom shaft2.repairing of bowl assembly and impleller3.supplying and fitting c.l spider bearing with rubber cut less bush-4nos4.supplying and fitting of worn-out nut-bolts,bolt-nut washer,gland body bush machining,other machining works,etc as per requirement, complete assembling the pump set and lowering including supplying all petty materials., cost for supplying and installation of required accesories for repair and maintenance of motor control panel such as:-150 amp contactor-2 no (for 1 no starter)160 amp,breaking capacity -36ka mccb 1 no56-90 a electronic overload relay-2 nostimer-2 nosvolt meter 1 nosamp motor 1 nospilot lamp 6 nosselector switch 4 nossingle phase preventer 2 nos[ all accessories of reputed make]with complete internal wiring with suitable size of copper wire and testing on load., repairing of 30hp c/f pump sets at clear water, cost for dismantling of 30 hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motor control panel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb - 50 amp,25ka,3pole-2 nos (for motor backup protection),mccb -100 amp,50ka,3pole-1 no (main mccb)2.overload relay 26-40 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required, repairing of 15hp c/f pump sets at clear water, cost for dismantling of 15hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motor control panel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb -25 amp,15ka,3pole-2 nos (for motor backup protection),mccb -50 amp,25ka,3pole-1 no (main mccb)2.overload relay 20-25 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required

CTN :45347978 Due date: 17 Jun, 202617 Jun, 2026 NA
Tender For providing of custom bid for services - 1 supply installation and commissioning of track based rail lubricator (electronic type) with dual applicator/wiper bar complete system as per rdso technical specification no irs t 48 along as mentioned in scope of work and ..,custom bid for services - 2 supply of grease for 5 year as per specification of lubricant vide rdso technical specification no irs t 48 along with as mentioned in scope of work and tender schedule

CTN :45334454 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For design, programming, installation, supply, testing and commissioning of bansgaon station, piprauli station, khajani station & unwal station electronic interlocking (ei) system (centralized type) conforming to rdso/spn/192/2019 ver.2 or latest (with latest amendment if any) for piprauli, khajani, unwal and bansgaon stations, as per sip along with indoor & outdoor work and telecom work in sahjanwa -bansgaon section (including maghar-piprauli y-connection) including part supply of materials at sahjanwa - bansgaon new line section of sahjanwa-dohrighat new line of ljn/bsb division of n.e.railway .

CTN :45334727 Due date: 16 Jun, 202616 Jun, 2026 NA
Tender For execution of s&t work for 1) provision of cctv, telephone and railnet facility in connection with work 'hatia ranchi jn. setting up of mechanised laundry of 6 tpd capacity in 2 shifts of 8 hrs at hte in ranchi division.', 2) provision of fois connectivity & cctv in connection with work ' electronic in motion weighing bridge(iemwb), cap-140 ton for bici'

CTN :45316034 Due date: 06 Jun, 202606 Jun, 2026 10.53 Lacs
Tender For so(enm)/grd/e-nit/26-27/13 dtd- 25.05.2026 - minor repairing & maintenance work of 2 nos.3mva, 33 kv/11 kv transformer installed at main central substation beniadih andestimate for leak proof, oil filtration denting & painting of 01 no. 3 mva, 33kv/11 kvtransformer installed at kabribad mines substation giridih area., supply of auxiliary relay 110v, supply of oil temperature meter with cable, supply of winding temperature meter with cable, supply of electronic buzzer hooter, supply of breather, replacement of silica gel, 2.5 sq.mm 4c frls cable, 1.5 sq mm 7c frls cable, replacement of top cover gasket/crok sheet, denting and painting of 33kv/11kv transformer for material and labour changes., filtaration of transformer oil and conservator tank, dismantling, transportation and erection of power transformer with other accessories, supply of leak proof material with labour charges, total impact of gst for the purpose of ctc

CTN :45098775 Due date: 05 Jun, 202605 Jun, 2026 NA
Tender For corrigendum : supply of supply - electronic type weigh bridge (road) , site work - electronic type weigh bridge (road)

State Government

CTN :45310432 Due date: 06 Jun, 202606 Jun, 2026 NA
Tender For work of provision, installation, commissioning & testing of separate electronic & electrical chemical earthing pit along with associated accessories for dcs upgradation system at unit#1 of 4 x 210 mw khaperkheda tps.

State Government

CTN :44930871 Due date: 28 May, 202628 May, 2026 5.90 Lacs
Tender For corrigendum : complete rewiring including supply of required material of existing office, sheds of ph 2 inside ph premises for utilizing office setup for 1x660 mw supercritical extension unit no. 12 at stps, sarni. - work part, point wiring for bulb / tube point with 2.5 sq. mm pvc insulated cable alluminium conductor for., a) medium point, b) long point, c) special point, point wiring for fan point with 2.5 sq. mm pvc insulated cable alluminium conductor for long point ., point wiring for 5 amp, 5 pin socket for medium point., point wiring for call bell point with 2.5 sq. mm pvc insulated cable alluminium conductor for long point ., wiring for circuit wiring with pvc insulated with alluminium conductor.a) 60 x 2.5 sq. mm. (30 circuit), point wiring for 15 amp, 5 pin socket outlet point on separate board with 4 sq. mm. pvc insulated with alluminium conductor with gi earthing. wire, removal of old / damaged wiring point with wooden board & batten & main switch., t/l fitting on pvc square box complete with connection & testing., installation of mcbs enclosure, d.p. mcbs and sp mcbs, installation of 63 amp ictpn main switch., installation of 200 amp ictpn main switch, supply part, supply of single pole 32 amp mcb s, supply of double pole, 32 amp mcb s., supply of 24 way mcb s steel enclosure double door, supply of 63 amp. ictpn tripple pole 415v, supply of 2x2 led false ceiling lighting panel, supply of 20/22 watt , led tubelight fittings, supply of single phase, 300 mm, 1400 rpm exhaust fan in steel frame body, supply of electronic ceiling fan socket type regulator, supply 63 amp 10ka four pole mcbs., supply of 8 way mcb s steel enclosure double door., supply of tripple pole with neutral link switch fuse unit 415 v, 200 amp tpn.

State Government

CTN :45108017 Due date: 02 Jun, 202602 Jun, 2026 2.41 Lacs
Tender For corrigendum : work contract for availing expert services for inspection, testing and rectification of m/s bhel make esp electronic controller and its optimization, tunning, troubleshooting and ios to reduce stack emission of 210 mw atps, mppgcl, chachai
 Loading, Please wait...

Connect us via What's Up