Get complete information related to latest Splicing Jig Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Splicing Jig Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Splicing Jig Tenders.
Tender For sitc of vrv type ac - 14 hp air cooled outdoor condensing unit supply , 20 hp air cooled outdoor condensing unit supply , 24 hp air cooled outdoor condensing unit supply , 14 hp outdoor unit installation testing commissioning , 20 hp outdoor unit installation testing commissioning , 24 hp outdoor unit installation testing commissioning , 1.5 tr 4 way cassette indoor unit supply , 4 tr 4 way cassette indoor unit supply , 1.5 tr 4 way cassette indoor unit installation , 4 tr 4 way cassette indoor unit installation , 3 tr split dx cassette air conditioning system supply , 3 tr split dx ac system installation testing commissioning , centralized remote controller unit supply , centralized remote control unit installation testing commissioning , 25.4mm od copper refrigerant pipe supply , 22.2mm od copper refrigerant pipe supply , 19mm od copper refrigerant pipe supply , 15.86mm od copper refrigerant pipe supply , 12.7mm od copper refrigerant pipe supply , 9.5mm od copper refrigerant pipe supply , 25.4mm od copper pipe installation testing commissioning , 22.2mm od copper pipe installation testing commissioning , 19mm od copper pipe installation testing commissioning , 15.86mm od copper pipe installation testing commissioning , 12.7mm od copper pipe installation testing commissioning , 9.5mm od copper pipe installation testing commissioning , vrf refrigerant y and t joints with insulation supply , vrf refrigerant y and t joints installation testing commissioning , 3 core 2.5 sqmm cu shielded communication cable supply , 4 core 2.5 sqmm cu shielded communication cable supply , 2 core 1.5 sqmm cu shielded communication cable supply , 3 core 2.5 sqmm cu cable laying , 4 core 2.5 sqmm cu cable laying , 2 core 1.5 sqmm cu cable laying , pvc condensate drain pipe with insulation supply , pvc condensate drain pipe installation , ms table top stands for outdoor units supply , ms table top stands for outdoor units installation , refrigerant gas r410a supply and filling , 4 core 10 sqmm xlpe armoured copper cable supply , 4 core 16 sqmm xlpe armoured copper cable supply , 4 core 10 sqmm xlpe cable laying testing commissioning , 4 core 16 sqmm xlpe cable laying testing commissioning , aluminium anodized partition for ac enclosure , light point wiring in pvc casing and capping , 2x2 led luminaire 24w recess surface mounted supply , led panel 2x2 24w installation testing commissioning , 4c 50 sqmm xlpe armoured copper cable supply , gi wire 8 swg supply and delivery , armoured cable laying on wall for ac power db , 4c 50 sqmm cable end termination both ends , tpn distribution board 8 way hvac odu , fp isolator 125 amp sitc , fp mcb 63 amp sitc , fp mcb 40 amp sitc , sp and n distribution board 12 way hvac idu , dp mcb 32 amp sitc , sp mcb 6 or 10 amp sitc , sfu 100a tpn at main switch board sitc , chemical earth electrode earthing arrangement sitc , camc first year air conditioning system , camc second year air conditioning system , camc third year air conditioning system , camc fourth year air conditioning system , camc fifth year air conditioning system
Tender For supply of oh of main steam line valve v2 6 , oh of steam by pass valve v2 27,15, and v2 7 , oh of es 3,4,5,6 and 7 , oh of v2 -82-84 and v2-81-a to 81c , oh of hd-21, hd-29, hd-30 and hd-31 , oh of nrv of h.p. heater and feed pump , oh of group protection valve of hph , oh of dw-4, 37,38,39,40,41 and ca 5 , oh of cst makeup valve v6 60 , oh of as-48 valve , oh of nrv of extraction line es-8 , oh of suction valve of bfp , oh condensate wtr throw off valve to condenser , oh throw off valve to cond and steam isolating of lph2 , oh of steam isolating valve of lph 3, 4 , oh of safety valve of aux prds or deaerator , oh of safety valve of h.p. heater , oh of safety valve of l.p. heater. , oh of safety valve of cbd tank. , oh of safety valve of flange or stud heatng , oh of safety valve of warm up line. , overhauling of actutator of as 48 valve , oh of actr feed line valvev2 81 or v2 82 or v2 83 or v2 84 , oh of actr of v2 7 or v2 15 or v2 27 , oh of actr drip line valve and ext line valve , oh of actr valve connected to condenser , oh of actr cst make valve , oh of actr of msv l and r , oh of actr of steam isolating valve to lph2 to 4 , oh of actr steam throw off valve to condenser , cut or weld or repl of hp valve 15 to 50mm , cut or weld or repl of hp valve 51 to 100mm , cut or weld or repl of h p valve 101 to 150mm , oh of butterfly valve of condenser , oh of dea and fst with internal painting , repair or replacement of broken hanger , tightening of loose hangers , cut or weld or repl of l.p. valve 15 to 50mm , cut or weld or repl of l.p. valve 51 to 100mm , cut or weld or joint of h.p. pipe 15 to 50mm , cut or weld or joint of h.p. pipe 51 to 100mm , cut or weld or joint of h.p. pipe 101 to 150mm , cut or weld or joint of h.p. pipe 151 to 300mm , lift or straight aprds hdr by cutting weldding , o h of lph 1a , 1b , o h of lph 2 3 and 4 , oh and attend flange leakage of gc i or ii , clean of turbine oil or h2 gas cooler str , repl of damaged sp. valve v2 38 , repl of damaged special valve v2 27 , oh of turbine oil coolers , oh of main ejectors of turbine , oh of h.p. heater , oh of lcv 3to15pcv-5, 14,16,17,tcv 8 , repl bend of lp drip connected to drip pump or condenser , cut damaged bend of hph drip cont to dea , cut weld or repl of h.p. valve 151 to 300mm , blank of crh line for ht and normalizing , oh of h.p. valve nrv in h.p. line , oh of l.p. valve nrv , oh of energy absorber of bfp , oh of dss of aux. prds.
Tender For supply of oh of main steam line valve v2 6 , oh of steam by pass valve v2 27,15, and v2 7 , oh of es 3,4,5,6 and 7 , oh of v2 -82-84 and v2-81-a to 81c , oh of hd-21, hd-29, hd-30 and hd-31 , oh of nrv of h.p. heater and feed pump , oh of group protection valve of hph , oh of dw-4, 37,38,39,40,41 and ca 5 , oh of cst makeup valve v6 60 , oh of as-48 valve , oh of nrv of extraction line es-8 , oh of suction valve of bfp , oh condensate wtr throw off valve to condenser , oh throw off valve to cond and steam isolating of lph2 , oh of steam isolating valve of lph 3, 4 , oh of safety valve of aux prds or deaerator , oh of safety valve of h.p. heater , oh of safety valve of l.p. heater. , oh of safety valve of cbd tank. , oh of safety valve of flange or stud heatng , oh of safety valve of warm up line. , overhauling of actutator of as 48 valve , oh of actr feed line valvev2 81 or v2 82 or v2 83 or v2 84 , oh of actr of v2 7 or v2 15 or v2 27 , oh of actr drip line valve and ext line valve , oh of actr valve connected to condenser , oh of actr cst make valve , oh of actr of msv l and r , oh of actr of steam isolating valve to lph2 to 4 , oh of actr steam throw off valve to condenser , cut or weld or repl of hp valve 15 to 50mm , cut or weld or repl of hp valve 51 to 100mm , cut or weld or repl of h p valve 101 to 150mm , oh of butterfly valve of condenser , oh of dea and fst with internal painting , repair or replacement of broken hanger , tightening of loose hangers , cut or weld or repl of l.p. valve 15 to 50mm , cut or weld or repl of l.p. valve 51 to 100mm , cut or weld or joint of h.p. pipe 15 to 50mm , cut or weld or joint of h.p. pipe 51 to 100mm , cut or weld or joint of h.p. pipe 101 to 150mm , cut or weld or joint of h.p. pipe 151 to 300mm , lift or straight aprds hdr by cutting weldding , o h of lph 1a , 1b , o h of lph 2 3 and 4 , oh and attend flange leakage of gc i or ii , clean of turbine oil or h2 gas cooler str , repl of damaged sp. valve v2 38 , repl of damaged special valve v2 27 , oh of turbine oil coolers , oh of main ejectors of turbine , oh of h.p. heater , oh of lcv 3to15pcv-5, 14,16,17,tcv 8 , repl bend of lp drip connected to drip pump or condenser , cut damaged bend of hph drip cont to dea , cut weld or repl of h.p. valve 151 to 300mm , blank of crh line for ht and normalizing , oh of h.p. valve nrv in h.p. line , oh of l.p. valve nrv , oh of energy absorber of bfp , oh of dss of aux. prds. , 2coat paint bcw,clr,bfp,cep,drip pump and line , 2coat paint cst,bcw pump ,swc tank,line,valve , 2coat paint hcplg,sw,bcw,cw exc clr line , 2coat paint air washer sys,cep or phos orhyd , 2coat spray paint syn super enamel lpc , 2coat spray paint front ped,barring gear , 2coat spray paint brg and housing turbine , 2coat spray paint cntl valve casing , 2coat spray paint condenser and line , 2coat spray paint main oil tank , 2coat spray paint main ejector , 2coat spray paint centrifuging machine , 2coat spray paint lube oil cooler , letter writing 2 inch size dia
Tender For invitation to pre-tender meet for steam condensate polishin g pkg in ecu (b957-300-lf-mr-8705) for bina petchem and refinery expansion projects (bprep) at bina refinery, madhya pradesh (india) of m/s bpcl
Tender For work of application of chemical resistant coating to internal surface and epoxy painting to external surface of condensate storage tank unit#7, cstps.
Tender For corrigendum : supply of steam water analysis system main spares and e and c - ph sensor , ph transmitter 4 to 20ma hart , specific conductivity sensor , specific conductivity transmitter 4 to 20ma hart , cat ion conductivity sensor with 1 cat ion exchange column , cat ion conductivity transmitter 4 to 20ma hart , do2 sensor , do2 transmitter 4 to 20ma hart material code , silica analyzer transmitter 4 to 20ma multi channel , sodium analyzer transmitter 4 to 20ma multi channel , hc analyzer 4 to 20ma , sample handling system for main steam superheated , sample handling system for drum water , sample handling system for hp feed water economizer inlet , sample handling system for deae ol fw , sample handling system for dm water , sample handling system for condensate blow down line , sample coolers , redundant chiller units 1 working 1 standby , shelf life items required at the time of commissioning , shelf life items required after commissioning in 1st lot , shelf life items required after commissioning in 2nd lot , training as per cl 14 of 2 mandays for 6 nos at site , supervision of e and c services charges at site , supervision of e and c visit charges , mandatory spares as per tech specs