Get complete information related to latest Spring Pin Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Spring Pin Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Spring Pin Tenders.
Tender For providing and fixing of various electrical accessories at district and session court metro jodhpur - sitc of ip20 smd mid power led batten type integrated light fixture made from powder coated extruded aluminium housing with in built driver , system lumen efficacy 110 lm/watt output only at cw (5700k to 6500k) , internal surge protection of 4.0 kv with short & open circuit protection ,thd 10% , p. f. 0.95, cri >80 , life time of minimum 50000 burning hours with , 70% of intial lumen maintaned till life ends , cct 3000 k / 4000 k / 5700 k /6000 k/6500 k (as per ansi bin) as required., 1170mm(+/-10%) led batten with min. lumen output 2200 lm, sitc of ip-20 led recessed / surface mounted, round / square backlit & smd mid power led downlight with power coated die-cast aluminum housing with uv stabilized non yellowish diffuser with bis compliance 4.0 kv surge protected isolated driver, with short & open circuit protection input 320vac-48 hr protection, input 350vac-2 hr protection), having efficiency > 85% . system lumen efficacy of 110 lm / watt,at cw (5700k to 6500k) , thd 10 % , pf. 0.95, cri >80, life time of minimum 50000 burning hours with , 70% of intial lumen maintaned till life ends , cct 3000 k / 4000 k/ 5700 k /6000 k/6500 k (as per ansi bin) as required., recessed mounting, minimum lumen output 1950 lm, sitc of ip20, 2x2 led surface/ recessed mounting backlit & smd mid power type led light fixture not less than 35 mm housing depth made from crca sheet steel housing, high purity / transmissivity uv stabilized non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 v, hv cutoff - lv cutoff should be 300-100v . high efficiency with 4 kv internal surge protection bis certified isolated driver having efficiency > 85% , with short & open circuit protection ( input 320vac-48 hoursprotection,input 350vac-2 hours protection) (integral with light fixture). system lumen efficacy of 120 lm/watt ,thd 10 % , p.f. 0.95,cri >80 , life time of minimum 50000 burning hours with , 70% of intial lumen maintaned till life ends , cct 3000 k / 4000 k / 5700 k /6000 k/6500 k (as per ansi bin) as required., recessed mounting, minimum lumen output 4320 lm, providing & fixing of bee star rated copper wounded with class of insulation f, double ball bearing capacitor start, aluminium body & aluminium blade ceiling fan conforming to all the performance requirements laid down in is 374:2019 with down rod up to 30 cm with secondary support safety cable ( steel rope) , cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor and making connection testing etc. as required., 1200 mm sweep bee 1 star rated (service value >=4.0 to 4.5 ), providing & fixing of ventilating fans capacitor start, copper wounded, single phase with pvc impeller, abs body, automatic openable louver shutter in existing opening including making connection, testing etc. as required., 200 mm sweep minimum air delivery 450 cum / hour, providing & fixing of 450 mm sweep oscillating type wall mounting / pedestal type fans with three speed, on and off position, sintered iron bush oil impregnated, with metal front and back 120 or more ribs guard; three no. aluminium blades, minimum air delivery 100 cum. / minute , minimum service value 1.11 cum./min/watt, noise level should be = 75 db, power consumption = 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required., wall mounting type with adjustable vertical angle, supplying and laying fr pvc insulated & unsheathed flexible copper conductor of following nominal sizes with isi marked (is:694) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from copper, stranding in acc. to is:8130/iec 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation pvc type a/c/d , flame retardant as per is 10810-53, better amperage rat
Tender For supply of materials and erection for shifting of control room pannel at 33/ 11 kv sub station bharsawa distt. kaushambi under deposit scheme on turnkey basis under edc, kaushambi - name of work: supply, carriage & erection of materials for control room pannel shifting of shiffting of 33/11 kv s/s bharsawa distt. kaushambi, supply of centralised materials, 11 kv switch gear 600/300/5a 350 mva i/c, 11 kv switch gear 200/100/5a 350 mva o/g, 11 kv 3x300 mm2 xlpecable, 11 kv 3x120 mm2 xlpecable, 24 volt battery, 24 volt battery charger, pcc. 8.5 mtr. long for feeder, 11 kv tpmo switch with fixing clamp, 11 kv top channel, 11 kv dropper angle, earthing complete, stay set complete, 11 kv polymer pin insulator, 11 kv polymer disc insulator, 11 kv disc fiting, 33 kv control panel t/f, acsr weasel conductor, supply of de-centralised materials, 11 kv 3x120 mm2 xlpe cable jointing kit o/d & i/d, control cable 4x2.5 mm2, control cable 2x2.5 mm2, g.i. pipe 6 " dia, rubber matting, clamp with nut & bosts, earth wire clamp for pcc pole, stay clamp for pcc pole, top channel clamp pcc pole, dropper channel clamp pcc pole, g.i. strip 35x6 mm, carriage of following material, pcc pole 8.5 mtr. long., structure of la, 33kv isolator, 33 kv cts, single t/f control pannel, 33kv vcb,11 kv outgoing. incoming pannel, battery & battery charger and other associated accessiories etc. (availibility at concern store center of store division), erection work, installation of 33 kv single transformer control pannel 2 no., incoming 2 no. and 7 no. outgoing in the switchgear room and grouting the pannel by rag bolt using cement, sand mortar in ratio 1:3. work includs fitting of all accessories in all respect with complete connection of control cable with pannel. all material will be provided by the contractor except vcb and crp., construction of cable trenchs with top cover and laying of control cable for vcb, c.t. & t/f control pannel etc. as per direction of engineer. trenchs to be 12 wide and 9 deep. work includes digging, of trench, concreting of the foundation in the ratio 1:3:6 r.b. wall 9 wide with cement mortar 1:4 and plastering inside the trench in the ratio 1:3 and sand filling in the trench. all material will be provided by the contractor., earthing of 11 kv indoor equipments, switchgears as per resspo drawing. with g.i. strip of size 35x6 mm. g.i. strip fully welded at both ends and to be connected with earthmat,, erection of dp with pcc pole 8.5 mtr long with all accessaries and grouting of the pcc pole with cement, sand and brick ballast ratio 1:4:8 size 0.45x 0.45x 1.5 mtr deep under the ground as per drawing no. res-6.(cement, sand, brick, ballast shall be provided by the contractor.), installation of 24 volt battery and battery charger with cabinet in the switch gear room, by grouting base channel 100 x 50 x 6 x 1000mm. fixing of rag bolt., laying of 11 kv 3x300/3x185/ 3x120 sqmm. xlpe cable by digging 0.75 mtr. deep trench, putting layer of sand in the bottom, ramming it, laying of cable over it rmt and covering the cable from sides and top by laying bricks, finally covering the same by earth and levelling of the same, all the materials, except cable, will be pvovided by the contractor., fixing and termination of outdoor/ indoor heat shrinkable cable boxes of size 3 x300/3x185/3x120 sqmm. xlpe cable. boxes will be supplied by the contractor, sundries ( as per site requirement/emergency work), safe dismantling of 11 kv o/g pannel & received back to store, laying of weasel conductor with the help of aluminium roller by hanging three nos. on each support in a manner taking sufficient care to ensure safety of weasel conductor against rubbing on ground, precaution for safety of crops is also to be taken. the work includes jointing of conductor by providing jointing sleaves, stringing of conductor upto correct sag and binding of conductor with insulators on each support. all material shall be provided by contractor such as join
Tender For bid to ras supply of led bulb 20 watt , 40 wt led tube light 4 ft long complete set , led tube light 20w completed with tube rod , led flood outdoor light 1000w , bulk head light 9w complete fitting , connected led ceiling light 18w , exhaust fan 300mm sweep , switch 5 amp pinao type , 5 pin 15 amp s s combo , curtain rod for door of size 1 point 3 mtr and 20 mm dia , curtain rod for window of size 1 point 5 mtr and 20 mm dia , electric bell , 5 amp s s combo with pvc mounted box , switch 5 amp pinao type including mounting box , cp towel rail 18 oblique 20mm dia 600mm long , carbon a v gac , sand , jumbo thread , pp jumbo super , 1 hp motor repair , molti port valve , ro membrane 40 int0 40 , jumbo filter , service charge , all pvc connection change , ro control panel , electronic dozing pump , lcm liquid , plastic pipe 1 point 5 inch , plastic pipe 2 inch , ht wire , false ceiling , internal wiring 1 point 5 sqmm , re-wiring 2 point 5 sqmm , looking mirror 5 point 5mm thick of size 600 into 450mm , pvc door , bulk head light 9w , pvc rain water pipe 110mm dia connected item such as t band elbow etc , mcb dp 32 amp , mcb 6 amp to 32 amp , mcb 63 amp , mcb 16 amp , 32 amp mcb , ceiling rose 2 to 3 terminal , ceiling fan 1200mm sweep , desert cooler 500mm sweep , pt switch 5 amp , modular switch mounting box , tds meter , ph meter , roter meter , tank connector , top cock tank valve on off tap , 1 inch cpvc pipe , t 4 oblique 4 , socket cpvc 4 oblique 4 , pvc connector , urine stop cock , cpvc bond , m seal , wall tap , wash basin tap , hack saw blade , 4 inch blade , gi pipe , l bend , union , 5 pin 5 amp switch socket combination with pvc mounted box , 5 pin 15 amp switch socket combination with pvc mounted box , stop cock brass 25mm , cp bid tap , water pump for desert cooler , flush , wire 2 core 1 point 5 sqmm , angle walve , cfl , cp tap , control panel relay card , air filter , fuel filter , oil filter , hot air deck , oil pressure sensor 4 to 20 ma , self solenoid , automatic voltage regulator avr , hub bearing , coolent oil , fuel line , battery 120 mah , kc 934v1 generator controller 12v dc , kirlaskor oil engines techical specifications self bosch
Tender For 06/2026-27/ - deposit work(running work) in sub division masauli under edd ramnagar. - safe loading carriage including unloading and proper stacking of following materials from central store barabanki / je store to site of work., pcc pole /stp pole 8.5/11/13 mtr long, 11kv pin insulator ., 11kv disc insulator ., 11kv x-arm, ms earthing rod, transformer 25/63/100 kva, abc cable 3x50/95 sq. mm., abc cable 1x25+1x16 sq. mm., 11 kv xlpe cable 3x70++3x120+3x185 sqmm, acsr weasal conductor, lt d.b. box, 11 kv ct/pt unit, 11 kv metering cubical/pilfer, stay set complete, other line material, dragging of pole from je dump store to site, erection of stay set of 16x1800 mm rod duly painted with red oxide,anchor plate, and stay insulate etc., stringing and sagging of 11 kv line with acsr weasal conductor including nuzzling binding and jumpering (weasal conductor will be provided by the department), pipe earthing ( boring type 40 feet), installation of mounting of following capacity of transformer including its connection between 11 kv and lt line mounting provinding crimping type aluminium lugs of required size.( all the material except transformer will be arranged by the contractor), mounting of 25/63/100 kva tranformer, installation of fixing 11 kv ct/pt with required meterial., installation of fixing 11 kv pilfer unit with required meterial., errection of substation type double pole with pcc /stp 8.5/11/13 pole mtr. long . including mounting of top channal dropper channel, base angle with clamps with nut & bolt, fitting of 33/11 kv pin & pin insulator., errection of single pcc /st pole for stringing, jumpharing and sagging of conductor 1/6 of total length of poles, stringing and sagging of lt 1x16 abc cable (lt abc cable will be provided by the department), stringing and sagging of lt 3x50 /95abc cable (lt abc cable will be provided by the department), installation of d.b. box, earthing of pole with ms earthing., provinding & fixing of various type materials. all materials shall be supplied by the contractor., nut & bolt, pg clamp, clamp for top/ dropper and t-off2/stay/lt etc., gi pipe 3"&4 dia, l t insulator, looping and choopping of tree branches in laying on the route of line., laying of 11kv xlpe cable 3x70, 120,185 sq. by mm manually, concreating and pilinthing of st& pcc pole 18x24 cm., fabricate with hole suitable size in steel items, receive from central store light as top channel/dropper channel sub station base angle etc., looping of cable and mounting of pole., gaurding of 11 kv line, dismentaling of 11 kv line & poll, other line work
Tender For deposit work(running work) in sub division ramnagar under edd ramnagar. - safe loading carriage including unloading and proper stacking of following materials from central store barabanki / je store to site of work., pcc pole /stp pole 8.5/11/13 mtr long, 11kv pin insulator ., 11kv disc insulator ., 11kv x-arm, ms earthing rod, transformer 25/63/100 kva, abc cable 3x50/95 sq. mm., abc cable 1x25+1x16 sq. mm., 11 kv xlpe cable 3x70++3x120+3x185 sqmm, acsr weasal conductor, lt d.b. box, 11 kv ct/pt unit, 11 kv metering cubical/pilfer, stay set complete, other line material, dragging of pole from je dump store to site, erection of stay set of 16x1800 mm rod duly painted with red oxide,anchor plate, and stay insulate etc., stringing and sagging of 11 kv line with acsr weasal conductor including nuzzling binding and jumpering (weasal conductor will be provided by the department), pipe earthing ( boring type 40 feet), installation of mounting of following capacity of transformer including its connection between 11 kv and lt line mounting provinding crimping type aluminium lugs of required size.( all the material except transformer will be arranged by the contractor), mounting of 25/63/100 kva tranformer, installation of fixing 11 kv ct/pt with required meterial., installation of fixing 11 kv pilfer unit with required meterial., errection of substation type double pole with pcc /stp 8.5/11/13 pole mtr. long . including mounting of top channal dropper channel, base angle with clamps with nut & bolt, fitting of 33/11 kv pin & pin insulator., errection of single pcc /st pole for stringing, jumpharing and sagging of conductor 1/6 of total length of poles, stringing and sagging of lt 1x16 abc cable (lt abc cable will be provided by the department), stringing and sagging of lt 3x50 /95abc cable (lt abc cable will be provided by the department), installation of d.b. box, earthing of pole with ms earthing., provinding & fixing of various type materials. all materials shall be supplied by the contractor., nut & bolt, pg clamp, clamp for top/ dropper and t-off2/stay/lt etc., gi pipe 3"&4 dia, l t insulator, looping and choopping of tree branches in laying on the route of line., laying of 11kv xlpe cable 3x70, 120,185 sq. by mm manually, concreating and pilinthing of st& pcc pole 18x24 cm., fabricate with hole suitable size in steel items, receive from central store light as top channel/dropper channel sub station base angle etc., looping of cable and mounting of pole., gaurding of 11 kv line, dismentaling of 11 kv line & poll, other line work